Vertical submerged mixed-flow pumps combine the high flow capacity of axial-flow pumps with the greater head capability of centrifugal pumps. The impeller and part of the pump casing operate below the liquid level; liquid enters axially and is discharged at an angle through a guide-vane assembly or volute. The main product families include HL, HLB(K), HLC, MFY and LK.
Send Inquiry
Description

Product Overview

 

Vertical submerged mixed-flow pumps combine the high flow capacity of axial-flow pumps with the greater head capability of centrifugal pumps. The impeller and part of the pump casing operate below the liquid level; liquid enters axially and is discharged at an angle through a guide-vane assembly or volute. The main product families include HL, HLB(K), HLC, MFY and LK.

Main series

HL vertical mixed-flow pump: A single-stage, single-suction, vertical volute-type mixed-flow pump. It features high efficiency, compact size, low weight and a pump casing that can rotate through 360°. It is designed for clean water or liquids with similar physical and chemical properties, at temperatures up to 50°C.
Flow: 540–72,000 m³/h; head: 3.4–30 m.

HLB(K) vertical long-shaft diagonal-flow pump: A vertical single- or multistage mixed-flow centrifugal pump with guide vanes. Configurations include non-pull-out HLB, pull-out HLBK, pull-out type with the discharge above the foundation level HLKS, and adjustable-blade HLKT. It is designed for clean water, rainwater, seawater and wastewater below 55°C.
Maximum flow: 25,000 m³/h; maximum head: 70 m.

HLC vertical long-shaft multistage sump pump: Has a downward-facing inlet and horizontal discharge, and is installed on a single foundation. The pump is directly coupled to the motor and can convey clean water, wastewater containing some solids, industrial wastewater and seawater. The standard stated medium-temperature limit is 80°C. Submergence depth can reach 20 m.

MFY vertical sump pump: A single-stage, single-suction, long-shaft vertical centrifugal pump designed to ISO 2858 and ISO 5199. Its submerged section operates in the liquid, with the shaft seal above the liquid and not in contact with the medium. Configurations include self-flushing or external flushing, and open or closed impellers.

LK pull-out vertical long-shaft mixed-flow pump: A single- or multistage vertical centrifugal or mixed-flow pump with guide vanes. It is designed for clean water, rainwater, scale-pit water, wastewater and seawater below 55°C.
Flow: 30–70,000 m³/h; head: 7–200 m. Special designs are stated to permit temperatures up to 90°C.

 

Product Features

 

1. High efficiency, large flow and moderate-to-high head

Mixed-flow pumps have a specific speed between that of centrifugal and axial-flow pumps. The source states an efficiency range of 71–90%, with a broad high-efficiency operating region. Flow can reach tens of thousands of cubic metres per hour while maintaining stable operation.

The HL series covers flows from 540 to 72,000 m³/h. It is suited to duties where an axial-flow pump may not provide enough head and a conventional centrifugal pump may not provide enough flow.

 

2. Submerged impeller, no priming required

The impeller and part of the guide-vane assembly operate directly below the liquid surface. The pump therefore starts without vacuum priming and does not require a foot valve. Its submerged arrangement can provide a favorable available net positive suction head (NPSHA), helping reduce cavitation risk at high flow.

The HLC inlet is fitted with a screen. Its net inlet area is stated to be more than 3.5 times the cross-sectional area of the discharge column pipe, reducing inlet losses.

 

3. Vertical installation with reduced footprint

The motor and pump can be installed on a single foundation or mounted on separate platforms in a two-level arrangement. The floor area is stated to be about half that of a comparable horizontal pump.

The LK design has a compact structure, and the pump length below the foundation can be adjusted to suit the installation, potentially reducing pump-house construction costs.

 

4. Guide-bearing lubrication and cooling arrangements

  • HLC: Guide bearings may use reinforced filled PTFE, Thordon® bearing material or nitrile rubber. The shaft journal is protected by a sleeve. For clean-water service, external bearing-flushing water may not be required. For wastewater or liquids containing particles, clean pressurized water must be supplied for cooling and lubrication. Flow and pressure switches can be added for remote monitoring and low-water protection.
  • LK: The pumped liquid can be filtered or settled before being used for self-flushing and lubrication of the guide bearings.
  • HLB(K): Rubber or Thordon guide bearings are used. Clean pressurized water is supplied through the protective tube, with a flow switch controlling the water supply to prevent bearing damage from insufficient flow.

 

5. Pull-out rotor for easier maintenance

Large-bore pumps, typically those with a nominal diameter of 1,000 mm or greater, often use a pull-out rotor design. The rotor assembly can be removed for impeller and guide-vane maintenance without dismantling the casing or connected piping.

HLB(K) configurations include:

  • HLB: Non-pull-out type
  • HLBK: Pull-out rotor type
  • HLKS: Pull-out type with the discharge above foundation level
  • HLKT: Adjustable-blade type

 

6. Shaft sealing above the liquid

The submerged section has no rotating shaft seal. The shaft-seal arrangement is above the installation foundation and does not directly contact the pumped medium, reducing the risk of leakage.

The MFY uses a labyrinth or packing seal to limit the escape of vapor from the medium. The HLC has an automatic shutoff shaft-seal arrangement at the end of the guide bearing to prevent liquid from flowing back into the bearing area after shutdown.

 

7. Materials for corrosion and wear resistance

Cast iron and ductile iron are typical choices for standard duties. Seawater service can use seawater-resistant stainless steel together with sacrificial-anode or impressed-current cathodic protection.

For sand- or slag-bearing liquids, high-chromium alloy or duplex-steel impellers and sleeves can be specified. An external clean-water flushing system can also be added to protect the water-lubricated guide bearings.

 

8. Sectional column-pipe construction

The intermediate shaft, discharge column and protective tube are assembled in sections. The number of discharge-pipe sections can be adjusted to suit the required submergence depth.

The HLC uses a proprietary sleeve coupling for intermediate shaft connections. The source states that this improves radial concentricity by a factor of ten compared with conventional connections and reduces overall vibration by more than 70%. Impellers and guide-vane assemblies can also be arranged in multiple stages to meet higher head requirements.

 

Applications

 

Vertical submerged mixed-flow pumps are used for large-flow, low-to-medium-head duties in power generation, metallurgy, municipal water systems, water conservancy and shipyards.

  • Power plants and industrial cooling water: Condenser cooling-water systems at thermal, nuclear and gas-fired power plants, large blast-furnace cooling systems, and chemical-reactor cooling circuits. For required heads of approximately 8–20 m, the HL mixed-flow pump may be more economical than an axial-flow pump.
  • Municipal water supply and waterworks: Intake from rivers, lakes and reservoirs, and raw-water transfer, typically at heads of 5–20 m.
  • Metallurgy and steelmaking: Scale-pit water, iron-oxide scale flushing water and wastewater containing iron filings.
  • Mine drainage: Mine inflow, open-pit drainage and mineral-processing wastewater. HLB(K) and HLC models are listed for wastewater containing sand.
  • Water-conservancy and flood-control projects: Agricultural irrigation and drainage, inter-basin water transfer, and urban flood-control pumping stations. The source highlights heads of 8–15 m for urban flood drainage.
  • Shipyards and ports: Dry-dock drainage, harbor water-level regulation and water intake from floating docks. The source identifies the HL series as suitable where the required head exceeds the usual economical range for axial-flow pumps.
  • Petrochemical and chemical industries: Large circulating cooling-water systems, corrosive industrial wastewater and seawater transfer. MFY and HLC pumps can be specified with corrosion-resistant materials.
  • Wastewater treatment plants: Inlet pumping and intermediate lift stations. At heads of approximately 8–12 m, the HL series offers high flow and efficiency.

 

Technical Specifications

 

1. Design Standards

  • HL and HLB(K): Designed, manufactured and tested with reference to GB/T 13008, Technical Conditions for Mixed-Flow and Axial-Flow Pumps.
  • MFY: Rated performance and flange dimensions are stated to be equivalent to ISO 2858; technical requirements follow ISO 5199.
  • HLC: Designed with reference to GB/T 5657 and applicable hydraulic-performance standards.

Certain products may be designed to API or other international standards if specified by the customer.

 

2. General Range by Series

Series

Flow range

Head range

Maximum submergence

Medium temperature

Design standard

HL

540–72,000 m³/h

3.4–30 m

≤18 m

≤50°C

GB/T 13008

HLB(K)

Up to 25,000 m³/h

Up to 70 m

Custom

≤55°C; special design up to 90°C

GB/T 13008

HLC

Configured to order

Configured to order

≤20 m; greater depths may be possible

≤80°C

GB/T 5657 / manufacturer standard

MFY

Configured to order

Configured to order

Custom

Determined by material

ISO 2858 / ISO 5199

LK

30–70,000 m³/h

7–200 m

Custom

≤55°C; special design up to 90°C

Manufacturer standard

These are stated series-level ranges. Actual operating limits depend on the model and configuration.

3. Drive and Direction of Rotation

HL and HLB(K) pumps are generally driven directly by vertical motors. Their impeller rotation may be clockwise or counterclockwise when viewed downward from the motor end, depending on the design.

The specified HLC rotation is counterclockwise when viewed from above at the motor end. The pump is connected using a sleeve coupling or flexible coupling.

A gearbox may be selected for high-power duties to achieve lower speed and high flow, and to reduce the required NPSH.

4. Impeller Types

Impellers are available in:

Closed construction: Higher efficiency; suited to clean water and mildly contaminated liquids.

Open construction: Better suited to clog-prone or abrasive service, including wastewater containing solids and pulp.

Material options include cast iron, cast steel, stainless steel and special alloys, selected according to the medium.

5. Bearings, Lubrication and Cooling

The above-liquid thrust bearing supports residual rotor thrust and rotor weight. It uses thin-oil lubrication, and cooling water may be supplied to cool the oil chamber. A Pt100 temperature sensor can be fitted in the thrust-bearing assembly to monitor bearing or oil temperature.

Submerged guide bearings may be made from Thordon, filled PTFE or nitrile rubber. When pumping wastewater, clean pressurized water must be supplied for cooling and lubrication. For seawater service, the pump can be fitted with sacrificial anodes or impressed-current cathodic protection to reduce electrochemical corrosion.

6. Shaft-Seal Arrangements

The submerged section has no rotary shaft seal. The shaft seal is positioned above the installation foundation.

  • HLC: Packing seal; replaceable sleeves are fitted at the shaft-seal and guide-bearing positions.
  • MFY: Labyrinth or packing seal.
  • Large pumps: May include an automatic shutoff shaft-seal arrangement to help prevent backflow or contaminants entering the bearing area after shutdown.

 

7. Materials of Major Components

Component

Material options stated in the source

Impeller

HT250 cast iron, QT500-7 ductile iron, 304/316 stainless steel, duplex steel, high-chromium alloy or wear-resistant stainless steel

Guide-vane body / volute

HT250 cast iron, 304/316 stainless steel, QT500-7 ductile iron or high-chromium alloy

Main shaft

45 steel, 40Cr, 17-4PH or duplex steel; shaft sleeves may be used for protection

Guide bearing

Thordon, filled PTFE, corrosion-resistant rubber, nitrile rubber or hard alloy

Column pipe / protective tube

Q235 carbon steel or 304 stainless steel

Pump base / motor base

HT200 cast iron or ZG25 cast steel

 

8. Special Operating Precautions

a. Impeller submergence:

Keep the impeller below the liquid surface during operation. The liquid level should remain above the impeller centerline by an adequate margin-typically at least 300 mm. Never operate the pump with the liquid below the impeller.

b. Cooling-water interlock:

When pumping wastewater or liquids containing solids, start the clean-water supply to the guide bearings before starting the pump. Start only after the required water flow and pressure are established. A flow or pressure fault during operation should trigger an alarm and automatic pump shutdown.

c. Freeze and sediment protection:

Drain the pump during winter shutdown or prolonged storage where freezing is possible. After pumping slurry containing solids, flush the casing and pipework with clean water after shutdown to limit deposits in the impeller and wear-ring clearances.

d. Standby pumps:

For critical duties, such as power-plant circulating-water systems, provide a standby arrangement-such as one duty plus one standby or two duty plus one standby-and rotate operation periodically.

e. Seawater protection:

In addition to selecting seawater-resistant materials, fit sacrificial anodes or an impressed-current cathodic-protection system where required. Inspect protection potential and anode consumption periodically.

 

Structural Drawings

 

product-1270-847

Performance Data Tables

 

Model

Flow rate (m³/h)

Head (m)

Speed (r/min)

Motor power (kW)

Nominal diameter (mm)

HWL100-15

100

15

1450

11

100

HWL150-15

150

15

1450

15

150

HWL150-17

150

17

1450

18.5

150

HWL200-15

200

15

1450

18.5

200

HWL200-17

200

17

1450

22

200

HWL250-15

250

15

1450

22

250

HWL250-17

250

17

1450

30

250

HWL300-12

300

12

1450

22

300

HWL300-15

300

15

1450

30

300

HWL350-12

350

12

1450

30

350

HWL350-15

350

15

1450

37

350

HWL400-10

400

10

1450

30

400

HWL400-12

400

12

1450

37

400

HWL400-15

400

15

1450

45

400

HWL500-10

500

10

1450

37

500

HWL500-12

500

12

1450

45

500

HWL500-15

500

15

980

55

500

HWL600-10

600

10

980

45

600

HWL600-12

600

12

980

55

600

HWL600-15

600

15

980

75

600

HWL700-8

700

8

980

45

700

HWL700-10

700

10

980

55

700

HWL700-12

700

12

980

75

700

HWL800-8

800

8

980

55

800

HWL800-10

800

10

980

75

800

HWL1000-8

1000

8

980

75

1000

HWL1200-6

1200

6

980

55

1200

HWL1200-8

1200

8

980

75

1200

HWL1500-6

1500

6

730

75

1500

HWL1500-8

1500

8

730

90

1500

HWL2000-5

2000

5

730

75

2000

HWL2000-6

2000

6

730

90

2000

HWL2500-5

2500

5

590

90

2500

HWL3000-5

3000

5

590

110

3000

HWL4000-4

4000

4

490

110

4000

HWL5000-4

5000

4

490

160

5000

HWL6000-3

6000

3

490

132

6000

HWL7000-3

7000

3

490

160

7000

If you cannot find the required specifications or model in our product range, please contact us at any time. Our technical specialists will provide prompt model selection assistance and a customized technical solution.

Hot Tags: vertical submerged mixed-flow pumps, China vertical submerged mixed-flow pumps manufacturers, factory

Send Inquiry