Product Overview
The FYS Fluoropolymer-Lined Vertical Sump Pump is a vertical, single-stage, single-suction centrifugal pump. The motor drives the pump through a flexible coupling and long shaft, while the pump casing, impeller and other wetted components operate partially submerged in the liquid. The pump is designed for corrosive liquids that contain no solid particles and are not prone to crystallization, particularly in highly corrosive service.
All parts in contact with the pumped medium are lined with F46 fluoropolymer. The lower sleeve is made of high-quality silicon carbide, providing both wear and corrosion resistance. The motor is mounted on a motor support above the baseplate. The pump casing, intermediate pipe, pump support and discharge pipe are bolted together as an assembly, which is secured to the vessel by the baseplate.
Model designation example: 50FYS-25
50: Suction inlet diameter (mm)
FY: Vertical sump pump designation
S: Fluoropolymer material designation
25: Rated head (m)
Product Features
1. F46 fluoropolymer lining for excellent corrosion resistance
The wetted components are fully encapsulated in molded F46 fluoropolymer-fluorinated ethylene propylene (FEP). This material resists almost all chemical media, with a few exceptions such as molten alkali metals and chlorine trifluoride. It offers good temperature resistance and is suitable for operating temperatures from −30°C to 150°C.
The lower sleeve is made of high-quality silicon carbide, combining corrosion and wear resistance.
2. Vertical submerged design to prevent shaft-seal leakage
The pump casing and impeller are partially submerged in the liquid, eliminating leakage through a shaft seal. This makes the pump suitable for corrosive, toxic, volatile, flammable and explosive liquids. Compared with horizontal pumps, the submerged vertical design avoids the shaft-seal leakage commonly associated with conventional pump configurations.
3. Compact footprint and flexible installation
The vertical configuration keeps the pump footprint small, with the pump casing submerged in the liquid. It is suitable for installation on tanks, vessels, reaction kettles and sumps, making efficient use of available space.
The standard submergence depth is 0.8–3 m, with custom depths available.
4. Stable operation and long bearing life
Axial and radial loads are carried by a one-way thrust ball bearing and a single-row radial ball bearing housed in the bearing assembly, together with a plain guide bearing. The bearings are grease-lubricated.
Pumps with a submergence depth greater than 1 m are fitted with an intermediate submerged bearing. This guide bearing is lubricated by the pumped medium, helping ensure stable and reliable operation.
5. Reinforced composite connecting pipe
The connecting pipe uses a composite construction, with a steel pipe lined and externally coated with plastic. This provides the required strength while helping prevent deformation and problems caused by thermal expansion and contraction. The discharge pipe is made of steel with an internal lining and external coating of non-metallic material.
6. Broad performance range
The pump covers a flow range of 1.5–400 m³/h and a head range of 5–50 m, meeting requirements from low-flow laboratory applications to higher-flow chemical processes. Speeds of 2,900 r/min and 1,450 r/min are available.
7. Optional explosion-proof configuration
The pump can be configured for hazardous or non-hazardous areas. For use in hazardous areas, it can be fitted with an explosion-proof motor to meet the safety requirements of applications such as petrochemical service.
Applications
The FYS Fluoropolymer-Lined Vertical Sump Pump combines strong corrosion resistance with leak-free operation. Typical industries and applications include:
- Chemical industry: Transfer of corrosive liquids, including sulfuric acid, hydrochloric acid, nitric acid, hydrofluoric acid, phosphoric acid, caustic soda and ammonia solutions, across a range of concentrations.
- Petrochemical and fine chemical industries: Transfer of corrosive process fluids and organic solvents in refining and chemical plants.
- Pharmaceutical industry: Transfer of corrosive reaction media used in the production of pharmaceutical intermediates and active ingredients.
- Metallurgical industry: Circulation and transfer of electrolytes and pickling solutions in non-ferrous metal production.
- Electroplating and surface treatment: Circulation and transfer of plating solutions, pickling solutions and degreasing liquids.
- Environmental protection and water treatment: Acid and alkali wastewater neutralization and acid dosing in industrial wastewater treatment.
- Textile dyeing and finishing: Transfer of dyeing wastewater and corrosive dye solutions.
- Pulp and paper industry: Transfer of pulp-bleaching liquor and other corrosive chemicals.
- Food industry: Transfer of corrosive cleaning solutions used in food processing, when fitted with food-grade fluoropolymer materials.
- Power generation: Acid circulation in power plant flue gas desulfurization systems.
Technical Specifications
1. Design Standards
The product is designed in accordance with ISO 2858 and GB/T 5656. Some performance parameters are based on JB/T 8096. The pump's rated performance points and installation dimensions are aligned with international standards.
2. Construction and Operating Principle
The FYS is a vertical, single-stage, single-suction centrifugal pump with a long-shaft design. The motor is directly coupled to the pump shaft through a flexible coupling. The pump casing, intermediate pipe, pump support, discharge pipe and pipe flanges are bolted together as an assembly and secured to a baseplate. The complete pump is mounted on the vessel by means of the baseplate.
The pump casing and impeller are submerged in the liquid. During operation, liquid enters beneath the impeller, is pressurized by the impeller and is discharged upward through the discharge pipe.
Axial and radial loads-including hydraulic forces generated during operation and the weight of the impeller and rotor-are carried by a one-way thrust ball bearing, a single-row radial ball bearing and a sliding guide bearing. The bearings are grease-lubricated, while the guide bearing is lubricated by the pumped medium. The liquid level must therefore remain above the impeller centerline during operation.
Depending on the required insertion length L, the pump can be supplied with or without an intermediate guide bearing. Pumps with a submergence depth greater than 1 m are fitted with an intermediate submerged bearing to support smooth, reliable operation.
3. Material Options
Standard wetted-part materials:
- F46 fluoropolymer alloy: Lines the pump casing, impeller, pump cover and other components; resistant to almost all chemical media.
- Silicon carbide: Used for the lower sleeve, providing both corrosion and wear resistance.
Other material options:
- Reinforced polypropylene (FRPP): Cost-effective for general corrosive service.
- Polyvinylidene fluoride (PVDF): Offers greater temperature resistance and strength.
- Ultra-high-molecular-weight polyethylene (UHMWPE): Combines corrosion resistance with excellent wear resistance.
Connecting pipe:
Composite construction consisting of a steel pipe with internal and external plastic coating, designed to provide adequate strength and resist deformation.
4. Operating Conditions
- Flow rate (Q): 1.5–400 m³/h; common models cover 1.6–100 m³/h
- Head (H): 5–50 m; some models reach 50 m
- Speed (n): 2,900 or 1,450 r/min, standard options
- Design pressure: ≤1.0 MPa; up to 10 MPa for some models
- Medium temperature: −20°C to 150°C, depending on material; 0°C to 120°C for F46; 105°C to 150°C with special materials
- Submergence depth (L): 0.5–3 m; standard depth 0.8–2.5 m; custom depths available
- Motor power: 0.37–22 kW, selected based on medium density
5. Explosion-Proof Configuration
The pump can be configured for hazardous or non-hazardous areas. For operation in a hazardous area, an explosion-proof motor must be specified. Where explosive mixtures may be present, select a motor with the appropriate gas group and temperature class.
6. Important Operating Precautions
a. Before starting the pump, ensure that the pump casing is submerged. The liquid level must be at least 180 mm above the impeller centerline.
b. Start the pump in the direction indicated on the pump. Do not operate it in reverse.
c. During installation, ensure that the liquid level remains above the impeller centerline. The guide bearing is lubricated by the pumped medium.
d. Do not change the chemical composition of the pumped medium without authorization. Mixing different chemicals may cause a reaction or generate excessive heat, potentially damaging the pump casing.
e. When pumping hazardous liquids, dry running can cause the liquid inside the pump to overheat and vaporize. Hydrogen-containing chemical media may create a risk of deflagration or hydrogen explosion. Take appropriate safety precautions during operation.
f. In hazardous areas, select the motor strictly in accordance with the applicable explosion-protection requirements.
g. Before prolonged shutdown in winter, drain all liquid from the pump casing to prevent freeze damage.
7. General Performance Range
- Flow rate (Q): 1.5–400 m³/h across the available series
- Head (H): 5–50 m for the main series
- Speed (n): 2,900 or 1,450 r/min; high- and low-speed series
- Design pressure: ≤1.0 MPa; up to 10 MPa for some models
- Medium temperature: −20°C to 150°C, depending on wetted-part materials
- Submergence depth (L): 0.5–3 m; standard depth 0.8–2.5 m
- Motor power: 0.37–22 kW, selected based on medium density
- Inlet diameter: 25–100 mm
- Outlet diameter: 20–80 mm
- Impeller type: Single-suction, closed impeller; semi-open impeller available on some models
Structural Drawings

Performance Data Tables
|
Model |
Flow rate (m³/h) |
Head (m) |
Discharge diameter (mm) |
Motor power (kW) |
Speed (r/min) |
Submerged length (mm) |
Efficiency (%) |
NPSH required (m) |
Suitable medium temperature (°C) |
|
25FYS-10 |
1.5 |
10 |
20 |
1.5/2.2 |
2900 |
300~2500 |
28 |
2 |
-5~105 |
|
25FYS-18 |
3.6 |
18 |
20 |
2.2 |
2900 |
300~2500 |
32 |
2 |
-5~105 |
|
32FYS-20 |
6.3 |
20 |
25 |
3 |
2900 |
300~2000 |
34 |
2.5 |
-5~105 |
|
40FYS-15 |
5 |
15 |
32 |
2.2/3 |
2900 |
300~2500 |
45 |
2 |
-5~105 |
|
40FYS-20 |
10 |
20 |
32 |
3 |
2900 |
300~2500 |
48 |
2.5 |
-5~105 |
|
40FYS-30 |
10 |
30 |
32 |
4 |
2900 |
300~2500 |
45 |
2.5 |
-5~105 |
|
40FYS-40 |
10 |
40 |
32 |
4/5.5 |
2900 |
300~2500 |
38 |
3 |
-5~105 |
|
50FYS-20 |
15 |
20 |
40 |
46085 |
2900 |
400~3000 |
52 |
2.5 |
-5~105 |
|
50FYS-25 |
15 |
25 |
40 |
4 |
2900 |
400~3000 |
50 |
2.5 |
-5~105 |
|
50FYS-30 |
15 |
30 |
40 |
5.5 |
2900 |
400~3000 |
48 |
3 |
-5~105 |
|
50FYS-40 |
15/20 |
40 |
32 |
7.5 |
2900 |
500~2500 |
42 |
3 |
-5~105 |
|
50FYS-50 |
12.5/15 |
50 |
32 |
7.5 |
2900 |
500~2500 |
33 |
3.5 |
-5~105 |
|
65FYS-20 |
25 |
20 |
50 |
5.5 |
2900 |
500~2500 |
55 |
3 |
-5~105 |
|
65FYS-25 |
25 |
25 |
50 |
5.5 |
2900 |
500~2500 |
54 |
3 |
-5~105 |
|
65FYS-32 |
29 |
32 |
50 |
5.5/7.5/11 |
2900 |
500~2500 |
52 |
3.5 |
-5~105 |
|
65FYS-40 |
25/29 |
40 |
40 |
11 |
2900 |
500~2500 |
48 |
3.5 |
-5~105 |
|
65FYS-50 |
25/29 |
50 |
40/50 |
11 |
2900 |
600~3000 |
45 |
4 |
-5~105 |
|
80FYS-20 |
50 |
20 |
65 |
7.5/11 |
2900 |
500~3000 |
64 |
3.5 |
-5~105 |
|
80FYS-30 |
50 |
30 |
65 |
46341 |
2900 |
500~3000 |
62 |
4 |
-5~105 |
|
80FYS-34 |
50 |
34 |
65 |
15 |
2900 |
500~3000 |
60 |
4 |
-5~105 |
|
80FYS-40 |
50 |
40 |
50 |
18.5 |
2900 |
600~3000 |
55 |
4.5 |
-5~105 |
|
80FYS-50 |
50 |
50 |
50/65 |
18.5 |
2900 |
600~3000 |
50 |
5 |
-5~105 |
|
100FYS-20 |
100 |
20 |
80 |
15 |
2900 |
500~3000 |
68 |
4.5 |
-5~105 |
|
100FYS-25 |
100 |
25 |
80 |
15 |
2900 |
500~3000 |
66 |
4.5 |
-5~105 |
|
100FYS-32 |
100 |
32 |
80 |
15/22 |
2900 |
600~3000 |
64 |
5 |
-5~105 |
|
100FYS-40 |
100 |
40 |
80 |
18.5/22 |
2900 |
600~3000 |
62 |
5 |
-5~105 |
|
100FYS-50 |
100 |
50 |
80 |
30 |
2900 |
700~4000 |
58 |
5.5 |
-5~105 |
|
125FYS-20 |
200 |
20 |
100 |
22 |
1450 |
500~3000 |
65 |
4 |
-5~105 |
|
125FYS-32 |
160 |
32 |
100 |
30 |
1450 |
600~3500 |
68 |
4.5 |
-5~105 |
|
125FYS-50 |
200 |
50 |
100 |
45 |
1450 |
800~5000 |
65 |
5 |
-5~105 |
|
150FYS-20 |
240 |
22 |
125 |
55 |
1450 |
800~5000 |
68 |
5 |
-5~105 |
|
150FYS-32 |
380 |
30 |
125 |
90 |
1450 |
1000~6000 |
64 |
5.5 |
-5~105 |
|
150FYS-42 |
300 |
42 |
125 |
90 |
1450 |
1000~6000 |
65 |
5.5 |
-5~105 |
If you cannot find the required specifications or model in our product range, please contact us at any time. Our technical specialists will provide prompt model selection assistance and a customized technical solution.
Hot Tags: fys fluoropolymer-lined vertical sump pump, China fys fluoropolymer-lined vertical sump pump manufacturers, factory