Product Overview
The JH In-Tank Acid and Alkali-Resistant Pump is a vertical sump pump designed for installation inside tanks. Its pump casing and impeller are partially submerged in the liquid, while the motor is mounted above the tank. This compact arrangement helps minimize the installation footprint.
The main pump casing is precision injection-molded from engineering plastics such as FRPP and PVDF, providing corrosion resistance and structural strength. The motor shaft is made of SUS304 or SUS316L stainless steel; titanium alloy is also available for special operating conditions.
The JH series uses a dry shaft-seal arrangement designed to help prevent acidic fumes from entering the motor bearings. The pump is also designed to tolerate dry running, so temporary loss of liquid due to a falling tank level should not damage the unit. It is used for acid and alkali circulation in electroplating, PCB manufacturing, chemical processing, exhaust-gas treatment, wastewater treatment, anodizing and electrophoretic coating.
Product Features
1. Excellent corrosion resistance
The pump casing is injection-molded from engineering plastics such as FRPP (reinforced polypropylene) and PVDF (polyvinylidene fluoride). These materials resist a broad range of chemical media and are suitable for demanding acid and alkali applications.
- FRPP operating temperature: 0–75°C
- PVDF operating temperature: 0–90°C
2. Dry-running capability and operational safety
The pump has a shaft-seal-free design with an internal dry shaft seal. It is designed to withstand dry running without damage from friction in the absence of liquid.
An oil seal is fitted in the motor end cover to help prevent acidic fumes from reaching the motor bearings and protect key motor components.
3. Compact construction and convenient installation
The vertical design allows the pump to be installed directly above the tank, with the pump section extending below the liquid surface. No separate foundation or support frame is required, helping save space.
The pump casing, motor flange seat and discharge elbow are produced using standardized tooling, making installation, disassembly and routine maintenance more convenient.
4. Efficient, quiet operation
The impeller is designed using an optimized hydraulic profile to promote smooth flow and reduce energy losses. The pump operates with low noise, making it suitable for workplaces where noise levels matter.
5. Long service life
The motor shaft is available in SUS304, SUS316L or titanium alloy, selected according to the corrosiveness of the medium. A high-speed butt-welding process is used for the long shaft to support strength and operating stability. Main components are made from corrosion- and wear-resistant materials.
6. Low maintenance costs
Standardized components simplify assembly and repair. The dry shaft-seal design avoids the frequent replacement associated with conventional mechanical seals, helping reduce routine maintenance costs.
Applications
The JH pump is suitable for tank-mounted applications in a range of industries and processes:
- Electroplating: Circulation, filtration and transfer of plating solutions; continuous plating lines.
- Printed circuit board (PCB) manufacturing: Etchant circulation, developer transfer and rinse spraying.
- Chemical industry: Circulation, transfer and cooling of acidic and alkaline liquids.
- Exhaust-gas treatment: Recirculating spray in gas-scrubbing towers and acid–alkali neutralization.
- Wastewater treatment: Neutralization, transfer and circulation of acidic or alkaline wastewater.
- Anodizing: Circulation and cooling of anodizing bath solutions.
- Electrophoretic coating: Circulation and transfer of electrophoretic coating solutions.
- Electroless plating: Circulation of specialty solutions such as electroless nickel and copper plating baths.
- Etching and cleaning: Spray washing and chemical circulation for etching equipment.
The series is particularly suited to in-tank installation and can be operated in combination with equipment such as precision filter systems.
Technical Specifications
Materials
Pump casing: FRPP or PVDF
FRPP: 0–75°C
PVDF: 0–90°C
Pump shaft: SUS304 stainless steel, SUS316L stainless steel or titanium alloy, selected according to the medium.
Impeller: FRPP or PVDF, injection-molded to match the pump casing material.
Discharge elbow: FRPP or PVDF, with standardized molded connections.
Motor: Standard three-phase induction motor; explosion-proof motor from the BTS series available according to the installation environment.
General Performance Range
- Motor power: 0.37–7.5 kW (½–10 HP), with multiple ratings available
- Connection diameter: 25–65 mm (1–2½ in), depending on model
- Flow rate: Approximately 30–650 L/min, depending on model and operating conditions
- Head: Up to approximately 2.5–41 m, depending on model and operating conditions
- Frequency: 50 or 60 Hz, as specified
- Phases / poles: Three-phase; 2-pole or 4-pole standard configurations
- Insulation class: F
- Protection rating: IP55 standard
- Operating temperature: FRPP: 0–75°C; PVDF: 0–90°C
- Suitable specific gravity: ≤1.2 for the standard model; custom configurations available for higher-specific-gravity media
Model Designation
Example: JH-40-SK-3-5-V-F
|
Code |
Meaning |
|
JH |
Model series: JH in-tank vertical pump |
|
40 |
Discharge size; 40 = 1½ in, 50 = 2 in, 65 = 2½ in |
|
SK |
Construction type: vertical in-tank |
|
3 |
Motor rating in horsepower; available ratings include 1, 2, 3, 5, 7.5 and 10 HP |
|
5 |
Frequency: 5 = 50 Hz; 6 = 60 Hz |
|
V |
Pump casing material: V = PVDF; F = FRPP |
|
F |
Flange configuration, supplied according to requirements |
Installation and Operation
Installation
Install the pump vertically above the tank, with the pump casing and impeller below the liquid surface.
Select PVC or PP fittings for the discharge line according to site requirements.
Keep the motor above the tank to allow ventilation, cooling and convenient maintenance.
Operating precautions
Although the pump is designed to tolerate dry running, avoid prolonged dry operation where possible.
Periodically inspect the pump shaft and impeller for wear.
Select FRPP or PVDF according to the properties of the pumped medium.
PVDF is recommended for highly corrosive or high-temperature service.
Selection note:
The figures above are general reference data for the JH series. Confirm the flow, head and motor-power match for the specific duty with the manufacturer.
Structural Drawings

Performance Data Tables
|
Model |
Specific-gravity series |
Discharge diameter (mm) |
Power (HP) |
Power (kW) |
Poles |
Maximum head at 50 Hz (m) |
Maximum flow at 50 Hz (L/min) |
Approx. weight (kg) |
|
JH-32SK-1 |
≤1.1 |
50×32 |
1 |
0.75 |
2 |
17 |
160 |
23 |
|
JH-40SK-1 |
≤1.1 |
50×40 |
1 |
0.75 |
2 |
16.5 |
170 |
23 |
|
JH-40SK-2 |
≤1.1 |
50×40 |
2 |
1.5 |
2 |
25 |
260 |
25 |
|
JH-40SK-3 |
≤1.1 |
50×40 |
3 |
2.2 |
2 |
27 |
350 |
29 |
|
JH-40SK-5 |
≤1.1 |
50×40 |
5 |
3.75 |
2 |
29 |
450 |
32 |
|
JH-50SK-5 |
≤1.1 |
50×50 |
5 |
3.75 |
2 |
30 |
520 |
52 |
|
JH-50SK-7.5 |
≤1.1 |
50×50 |
7.5 |
5.5 |
2 |
38 |
620 |
70 |
|
JH-50SK-10 |
≤1.1 |
50×50 |
10 |
7.5 |
2 |
43 |
690 |
75 |
|
JH-32SP-1 |
≤1.4 |
50×32 |
1 |
0.75 |
2 |
16 |
150 |
23 |
|
JH-40SP-1 |
≤1.4 |
50×40 |
1 |
0.75 |
2 |
16 |
160 |
23 |
|
JH-40SP-2 |
≤1.4 |
50×40 |
2 |
1.5 |
2 |
24 |
220 |
25 |
|
JH-40SP-3 |
≤1.4 |
50×40 |
3 |
2.2 |
2 |
26 |
300 |
29 |
If you cannot find the required specifications or model in our product range, please contact us at any time. Our technical specialists will provide prompt model selection assistance and a customized technical solution.