Product Overview
Multistage vertical sump pumps use several impellers in series to increase the head beyond what is generally practical with a single-stage sump pump.
- DLY/YDB: Primarily used for oilfield gathering and transfer of oil or oil–water mixtures.
- LC long-shaft pumps and VTP deep-well pumps: Used for municipal water supply and drainage, metallurgical circulating water, flood control and drainage.
- DY: Designed for clean, particle-free liquids in petroleum and chemical applications.
The following table summarizes the stated general ranges for each series.
|
Pump series |
Flow range |
Head range |
Suitable temperature |
|
DLY |
5–300/400 m³/h |
15–600 m |
−40°C to +200°C |
|
LC long-shaft pump |
85–8,800 m³/h |
10–380 m |
≤55°C for clean water; ≤200°C for special configurations |
|
VTP long-shaft pump |
Up to 25,000 m³/h |
Up to 456 m |
−32°C to +200°C |
|
DY |
7.5–750 m³/h |
390–2,200 m |
≤200°C |
|
LHY molten sulfur pump |
0.1–400 m³/h |
40–200 m |
≤200°C; special designs stated to reach +550°C |
These figures are series-level reference ranges, not guaranteed operating points for an individual model.
Product Features
Multistage sump pumps combine staged pressure boosting with vertical, submerged installation. Their designs vary by series: DLY/YDB pumps focus on oil and oil–water mixtures; LC and VTP pumps serve high-flow water duties; and DY pumps are intended for very high-head clean-liquid service.
1. Multiple stages provide high total head
A multistage pump places several impellers on a common shaft. The liquid passes through each impeller and guide vane in sequence, gaining pressure at every stage. Total head is approximately the sum of the head produced by the individual stages.
The stated maximum heads are 380 m for the LC series, 456 m for the VTP series and up to 2,200 m for the DY series.
2. Stable operation with radial guide vanes
Radial guide vanes or sectional construction direct liquid evenly from one stage to the next. This design is intended to minimize radial-force disturbance between stages and support stable, efficient operation.
3. Configurations for different submergence depths
The intermediate shaft, column pipe and protective pipe are assembled in sections. Shafts are connected using threaded or sleeve couplings, and the number of discharge-pipe sections can be adjusted to suit the installation.
For submergence depths greater than 6 m, the source specifies shaft extensions and intermediate water-lubricated guide bearings. For depths beyond 10 m, a sectional long-shaft or multi-support arrangement is recommended. The number of stages on some models, such as DLY, can also be adjusted.
4. Axial-thrust balancing for high-pressure service
- DLY: A balance drum carries most of the axial thrust; a thrust ball bearing supports the residual load. The shaft seal combines labyrinth throttling and packing.
- LC: Impeller balance holes reduce axial thrust. Replaceable wear rings on the front and rear covers protect the impeller and guide-vane casing.
5. Bearing systems designed for extended service
The upper shaft is supported by double-row angular-contact ball bearings, while the lower shaft is supported by wear-resistant alloy sliding bearings. Upper bearings use grease or thin-oil lubrication; submerged sliding bearings are lubricated by the pumped liquid. The source describes water cooling for the bearing components.
6. Material options for different media
Wetted parts can be selected according to the pumped medium. Listed materials include QT600 ductile iron, 1Cr18Ni9Ti stainless steel and HT200 cast iron. Different stainless-steel grades can be specified for corrosive service.
7. Vertical installation and convenient maintenance
The pump is mounted directly above the vessel containing the liquid, requiring no additional floor area. The drive assembly sits on the motor frame and is driven through a coupling by an outdoor vertical explosion-proof motor. The range is intended to meet oilfield gathering duties as well as transfer of waste oil and wastewater.
Applications
The series is used for submerged lifting and transfer in the petroleum, chemical, power, metallurgical, mining and municipal sectors.
- Oilfield gathering: Transfer of crude oil and oil–water mixtures collected at wells and oil stations; also listed for pipeline transfer duties.
- Mine drainage and water supply: Mine drainage, factory and municipal water supply, acidic mine water and mine inflow.
- Petroleum and chemical industries: Transfer of particle-free petroleum products, liquefied petroleum gas and other flammable, explosive or toxic liquids in refining, petrochemical and chemical processes.
- Deep-well and high-head duties: LC and VTP pumps for deep-well water lifting and power-plant condenser circulating water; DY pumps for boiler feed and other high-head duties.
- Municipal water and wastewater systems: Urban water supply and drainage, flood control, stormwater discharge, and raw-water lifting at water and wastewater treatment plants.
- Metallurgy and steelmaking: Oxide-scale water in vortex-pit systems and circulating cooling water.
- Fire protection: Pressure boosting for high-pressure water-supply systems.
- Other industrial services: Clean water and chemical liquids with physical and chemical properties similar to water. For general service, liquid temperature is typically no higher than 80°C.
Technical Specifications
1. Design Standards
The main series are designed and manufactured to applicable national and industry standards. The VTP series is stated to follow GB/T 5657 and GB/T 13008. New sump-pump designs are stated to follow the GB 3836 explosion-protection standards. Other multistage pump sections follow the relevant hydraulic-performance standards for their design.
2. Multistage Arrangement
Multiple impellers are mounted in series on the same shaft. Liquid enters from the bottom and passes through successive impellers and guide vanes, gaining pressure at each stage. The number of impellers is selected to meet the required discharge head.
The source describes the guide vanes as radial, intended to avoid radial forces during operation and promote stable running.
3. Submergence-Depth Configuration
Submergence depth varies by series and can be customized:
- DLY: Standard depth 1.0–6.0 m; extensions may be specified.
- LC: Generally up to 18 m.
- VTP: Configurable according to user requirements.
For depths greater than 6 m, the source specifies intermediate guide bearings and sectional shaft extensions. For depths beyond 10 m, a multi-support arrangement is recommended.
4. Sealing System
Sealing arrangements vary by series:
- DLY: A shaft exit located in the low-pressure area uses packing with labyrinth throttling and pressure reduction.
- LC: Packing or mechanical sealing is available.
Submerged sliding bearings are generally lubricated by the pumped liquid. For wastewater or higher-temperature service, an external clean-water supply may be used for bearing lubrication and cooling.
5. Axial-Thrust Balancing
- DLY/YDB: A balance drum carries the main axial load, with a thrust ball bearing supporting the residual load.
- LC: Impeller balance holes reduce axial thrust; replaceable wear rings are fitted to the front and rear covers.
Rotor weight and residual axial thrust are supported by a thrust bearing in the motor frame or by a motor equipped with a thrust bearing.
6. Wetted-Part Materials
- HT200 cast iron: General clean water and neutral, non-corrosive liquids.
- QT600-3 ductile iron: Moderately corrosive service, including mildly corrosive oil–water mixtures.
- 1Cr18Ni9Ti: Corrosive service, including acidic or alkaline media.
- 304/304L stainless steel: General corrosive chemical service.
- 316/316L stainless steel: More corrosive service, including some chloride-containing media.
7. Operating Precautions
a. Before startup, confirm that the submerged section is fully immersed and that the liquid level is above the first-stage impeller centerline.
b. The pump is driven by an outdoor vertical explosion-proof motor mounted on the motor frame. Viewed from the motor end, the specified direction of rotation is counterclockwise. Do not run the pump in reverse.
c. For pumps with packing seals, periodically check leakage at the stuffing box and adjust the gland as required.
d. Before a prolonged shutdown, drain the pump and piping to prevent freeze damage or blockage from deposits.
e. For special corrosive or high-temperature media, provide the medium's name, temperature, concentration, density, viscosity and solids content when ordering so suitable materials, seals and cooling arrangements can be selected.
f. For wastewater or higher-temperature service, the guide bearing may require external clean-water lubrication and cooling.
8. General Performance Range
- Flow rate (Q): 6–400 m³/h for the DLY standard range; up to 8,800 m³/h for LC; up to 25,000 m³/h for VTP
- Head (H): 15–600 m for DLY; up to 2,200 m for DY
- Speed (n): 2,950 or 1,450 r/min, with 2,950 r/min more common
- Medium temperature: −40°C to +200°C; ≤80°C is stated as the standard configuration
- Medium viscosity: 0–200 cSt
- Submergence depth (L): 1.0–6.0 m standard for DLY; LC up to 18 m
- Motor power: 2.2–1,800 kW, depending on model and operating conditions
- Pump efficiency: 45–80.5%; LC is stated to reach 80.5%
- Reference standards: GB/T 5657 and other standards applicable to each design
- Installation: Vertical mounting above the storage vessel, with the motor above the liquid level
Structural Drawings

Performance Data Tables
|
Pump model |
Flow rate |
Head |
Pump rated speed n=1450r/min Motor power (kW) |
Pump mass |
||
|
p=1.0 |
p=1.35 |
p=1.84 |
||||
|
Motor power(KW) |
||||||
|
100YL-13 |
30 |
15.6 |
4 |
5.5 |
7.5 |
1100+100N |
|
60 |
12.5 |
|||||
|
120 |
9.7 |
|||||
|
100YL-20 |
30 |
24 |
7.5 |
11 |
15 |
1120+100N |
|
60 |
19.9 |
|||||
|
75 |
9.7 |
|||||
|
100YL-20A |
27.3 |
19.9 |
5.5 |
7.5 |
11 |
1120+100N |
|
54.6 |
16.5 |
|||||
|
68.3 |
13.8 |
|||||
|
100YL-2-25 |
30 |
31.2 |
7.5 |
11 |
15 |
1260+100N |
|
60 |
25 |
|||||
|
75 |
26.4 |
|||||
|
100YL-2-32 |
30 |
39.6 |
11 |
15 |
18.5 |
1320+100N |
|
60 |
32.4 |
|||||
|
75 |
26.4 |
|||||
|
100YL-2-40 |
30 |
48 |
15 |
22 |
30 |
1350+100N |
|
60 |
39.8 |
|||||
|
75 |
33.4 |
|||||
|
100YL-3-60 |
30 |
72 |
22 |
30 |
37 |
1460+100N |
|
60 |
59.7 |
|||||
|
75 |
50.1 |
|||||
|
100YL-3-60A |
27.3 |
59.6 |
15 |
22 |
30 |
1460+100N |
|
54.6 |
49.4 |
|||||
|
68.3 |
41.5 |
|||||
|
150YL-25 |
75 |
28.5 |
22 |
30 |
37 |
1460+140N |
|
150 |
25 |
|||||
|
190 |
19.5 |
|||||
|
150YL-25A |
68.3 |
22.8 |
15 |
22 |
30 |
1460+140N |
|
136.5 |
19 |
|||||
|
172.9 |
13.7 |
|||||
|
150YL-37 |
75 |
43.7 |
30 |
37 |
45 |
1520+140N |
|
150 |
36.6 |
|||||
|
190 |
30.3 |
|||||
|
150YL-37A |
68.3 |
35.1 |
22 |
30 |
37 |
1520+140N |
|
136.5 |
32.5 |
|||||
|
173 |
30.2 |
|||||
|
150YL-46 |
75 |
48.2 |
37 |
55 |
75 |
1580+140N |
|
150 |
46 |
|||||
|
190 |
43.2 |
|||||
|
150YL-60 |
75 |
64.5 |
45 |
55 |
75 |
1620+140N |
|
150 |
60.4 |
|||||
|
190 |
56.8 |
|||||
|
200YL-15 |
190 |
17.4 |
22 |
30 |
37 |
1500+160N |
|
300 |
14.5 |
|||||
|
360 |
11.9 |
|||||
|
200YL-23 |
190 |
26.8 |
37 |
55 |
75 |
1550+160N |
|
300 |
23 |
|||||
|
360 |
20.2 |
|||||
|
200YL-23A |
172.9 |
22.2 |
30 |
37 |
45 |
1550+160N |
|
273 |
19 |
|||||
|
327.6 |
16.7 |
|||||
|
200YL-2-29 |
190 |
34.8 |
45 |
55 |
75 |
1700+160N |
|
300 |
29 |
|||||
|
360 |
23.8 |
|||||
|
200YL-2-38 |
190 |
44.2 |
55 |
75 |
90 |
1800+160N |
|
300 |
37.5 |
|||||
|
360 |
32.1 |
|||||
|
200YL-2-46 |
190 |
53.6 |
75 |
90 |
132 |
1850+160N |
|
300 |
46.1 |
|||||
|
360 |
40.4 |
|||||
|
200YL-3-69 |
190 |
80.4 |
110 |
160 |
200 |
2000+160N |
|
300 |
69 |
|||||
|
360 |
60.6 |
|||||
|
200YL-3-69A |
172.9 |
66.6 |
90 |
132 |
160 |
2000+160N |
|
273 |
57 |
|||||
|
327.6 |
50.1 |
|||||
|
250YL-20 |
360 |
22.8 |
55 |
75 |
110 |
1540+180N |
|
480 |
19.8 |
|||||
|
540 |
17.8 |
|||||
|
250YL-20A |
327.6 |
18.9 |
37 |
55 |
75 |
1540+180N |
|
436.8 |
16.4 |
|||||
|
491.4 |
14.7 |
|||||
|
250YL-32 |
360 |
35.5 |
75 |
90 |
132 |
1600+180N |
|
480 |
31.5 |
|||||
|
540 |
29.1 |
|||||
|
250YL-32A |
327.6 |
29.4 |
45 |
55 |
110 |
1600+180N |
|
436.8 |
26.1 |
|||||
|
491.4 |
24.1 |
|||||
|
250YL-2-40 |
360 |
45.6 |
80 |
132 |
130 |
1600+180N |
|
480 |
39.6 |
|||||
|
540 |
35.6 |
|||||
|
250YL-2-51 |
360 |
58.3 |
132 |
180 |
250 |
1500+180N |
|
480 |
51.4 |
|||||
|
540 |
46.9 |
|||||
|
250YL-2-63 |
360 |
71 |
160 |
220 |
280 |
1850+180N |
|
480 |
63 |
|||||
|
540 |
58.2 |
|||||
|
300YL-25 |
540 |
31.2 |
90 |
132 |
160 |
2050+300N |
|
660 |
25 |
|||||
|
750 |
21.4 |
|||||
|
300YL-25A |
513 |
24.2 |
75 |
110 |
132 |
2050+300N |
|
625 |
20.8 |
|||||
|
712 |
16.9 |
|||||
|
300YL-39 |
540 |
42.6 |
132 |
180 |
250 |
2100+300N |
|
660 |
38.7 |
|||||
|
750 |
32.5 |
|||||
|
300YL-39A |
513 |
39.5 |
110 |
160 |
220 |
2100+300N |
|
625 |
32 |
|||||
|
712 |
21.3 |
|||||
|
300YL2-49 |
540 |
55 |
160 |
220 |
280 |
2150+300N |
|
660 |
49 |
|||||
|
750 |
13.2 |
|||||
|
300YL2-64 |
540 |
70.2 |
200 |
280 |
348 |
2250+300N |
|
660 |
63.5 |
|||||
|
750 |
57.2 |
|||||
|
300YL-19 |
750 |
22.2 |
90 |
132 |
160 |
2300+600N |
|
900 |
19.3 |
|||||
|
1050 |
16.1 |
|||||
|
350YL3-19A |
713 |
20 |
75 |
110 |
132 |
2300+600N |
|
855 |
17.4 |
|||||
|
998 |
14.5 |
|||||
|
350YL-30 |
750 |
33.5 |
160 |
220 |
280 |
2600+650N |
|
900 |
30.2 |
|||||
|
1050 |
25.5 |
|||||
|
350YL-30A |
713 |
30.2 |
132 |
180 |
250 |
2600+650N |
|
855 |
27.3 |
|||||
|
998 |
23 |
|||||
|
350YL-30B |
675 |
27.1 |
110 |
160 |
220 |
2600+650N |
|
810 |
24.5 |
|||||
|
945 |
20.7 |
|||||
|
350YL-48 |
750 |
51.8 |
220 |
315 |
|
2700+650N |
|
900 |
47.9 |
|||||
|
1050 |
42.5 |
|||||
|
350YL-48A |
713 |
46.7 |
200 |
280 |
|
2700+650N |
|
855 |
43.2 |
|||||
|
998 |
38.4 |
|||||
|
350YL-48B |
675 |
42 |
185 |
250 |
|
2700+650N |
|
810 |
38.8 |
|||||
|
945 |
34.4 |
|||||
|
350YL2-60 |
750 |
67 |
280 |
400 |
|
3250+650N |
|
900 |
60.4 |
|||||
|
1050 |
51 |
|||||
|
350YL2-60A |
713 |
60.5 |
250 |
355 |
|
3250+650N |
|
655 |
54.5 |
|||||
|
998 |
46 |
|||||
|
400YL-25 |
1050 |
28.3 |
160 |
220 |
400 |
2700+700N |
|
1320 |
25 |
|||||
|
1500 |
22 |
|||||
|
400YL-25A |
998 |
25.5 |
132 |
180 |
250 |
2700+700N |
|
1254 |
22.6 |
|||||
|
1425 |
19.9 |
|||||
|
400YL-39 |
1050 |
44.3 |
250 |
355 |
|
3100+700N |
|
1320 |
39 |
|||||
|
1500 |
34.3 |
|||||
|
400YL-39A |
998 |
40 |
200 |
280 |
|
3100+700N |
|
1254 |
35.2 |
|||||
|
1425 |
31 |
|||||
|
400YL-39B |
945 |
35.9 |
185 |
250 |
|
3100+700N |
|
1188 |
31.6 |
|||||
|
1350 |
27.8 |
|||||
|
400YL-62 |
1050 |
68.5 |
355 |
500 |
|
3300+700N |
|
1320 |
61.9 |
|||||
|
1500 |
56.6 |
|||||
|
400YL3-62A |
998 |
61.8 |
315 |
450 |
|
3300+700N |
|
1254 |
55.9 |
|||||
|
1425 |
51.1 |
|||||
|
400YL-62B |
945 |
55.5 |
280 |
400 |
|
3300+700N |
|
1188 |
50.1 |
|||||
|
1350 |
45.8 |
|||||
|
450YL-17 |
1500 |
19.7 |
160 |
220 |
315 |
3280+650N |
|
1740 |
17.4 |
|||||
|
1920 |
15.7 |
|||||
|
450YL-17A |
1425 |
17.8 |
132 |
185 |
250 |
3280+650N |
|
1653 |
15.7 |
|||||
|
1824 |
14.2 |
|||||
|
450YL-27 |
1500 |
29.8 |
220 |
315 |
400 |
3430+750N |
|
1740 |
27.2 |
|||||
|
1920 |
25 |
|||||
|
450YL-27A |
1425 |
26.9 |
185 |
250 |
355 |
3430+750N |
|
1653 |
24.5 |
|||||
|
1824 |
22.6 |
|||||
|
450YL-27B |
1350 |
24.1 |
160 |
220 |
315 |
3430+750N |
|
1566 |
22 |
|||||
|
1728 |
20.3 |
|||||
|
450YL-43 |
1500 |
46.2 |
315 |
450 |
|
3680+750N |
|
1740 |
43.1 |
|||||
|
1920 |
40.5 |
|||||
|
450YL-43A |
1425 |
41.7 |
280 |
400 |
|
3680+750N |
|
1653 |
38.9 |
|||||
|
1824 |
36.6 |
|||||
|
450YL-43B |
1350 |
37.4 |
250 |
355 |
450 |
3680+750N |
|
1566 |
34.9 |
|||||
|
1728 |
32.8 |
|||||
|
450YL2-54 |
1500 |
59.6 |
400 |
|
|
3800+750N |
|
1740 |
54.4 |
|||||
|
1920 |
50 |
|||||
|
450YL2-54A |
1425 |
53.8 |
355 |
500 |
|
3800+750N |
|
1653 |
49.1 |
|||||
|
1824 |
45.1 |
|||||
|
500YL-20 |
1920 |
21 |
200 |
280 |
450 |
3800+830N |
|
2160 |
20 |
|||||
|
2400 |
17.8 |
|||||
|
500YL-20A |
1824 |
19 |
185 |
250 |
355 |
3800+830N |
|
2052 |
18.1 |
|||||
|
2280 |
16.1 |
|||||
|
500YL-31 |
1920 |
34 |
315 |
450 |
|
4100+830N |
|
2160 |
31.4 |
|||||
|
2400 |
28.5 |
|||||
|
500YL-31A |
1824 |
30.7 |
280 |
400 |
500 |
4100+830N |
|
2052 |
28.3 |
|||||
|
2280 |
25.7 |
|||||
|
500YL-31B |
1728 |
27.5 |
250 |
355 |
450 |
4100+830N |
|
1944 |
25.4 |
|||||
|
2160 |
23.1 |
|||||
|
500YL-50 |
1920 |
52.8 |
500 |
|
|
4300+830N |
|
2160 |
49.8 |
|||||
|
2400 |
46.1 |
|||||
|
500YL-50A |
1824 |
47.7 |
450 |
|
|
4300+830N |
|
2052 |
44.9 |
|||||
|
2280 |
41.6 |
|||||
|
500YL-50B |
1728 |
42.8 |
355 |
|
|
4300+830N |
|
1944 |
40.3 |
|||||
|
2160 |
37.3 |
|||||
|
500YL2-63 |
1920 |
68 |
560 |
|
|
4700+830N |
|
2160 |
62.8 |
|||||
|
2400 |
57 |
|||||
|
500YL2-63A |
1824 |
61.4 |
500 |
|
|
4700+830N |
|
2052 |
56.7 |
|||||
|
2280 |
51.4 |
|||||
|
600YL-25 |
2400 |
29.7 |
315 |
|
|
4800+695N |
|
3000 |
25 |
|||||
|
3420 |
21.6 |
|||||
|
600YL-25A |
2280 |
26.8 |
280 |
|
|
4800+695N |
|
2850 |
22.6 |
|||||
|
3249 |
19.5 |
|||||
|
600YL-39 |
2400 |
28.3 |
500 |
|
|
5340+695N |
|
3000 |
25 |
|||||
|
3420 |
22 |
|||||
|
600YL-39A |
2280 |
25.5 |
450 |
|
|
5340+695N |
|
2850 |
22.6 |
|||||
|
3249 |
19.9 |
|||||
|
600YL-39B |
2160 |
44.3 |
355 |
|
|
5340+695N |
|
2700 |
39 |
|||||
|
3078 |
34.3 |
|||||
|
600YL-62 |
2400 |
40 |
710 |
|
|
5400+965N |
|
3000 |
35.2 |
|||||
|
3420 |
31 |
|||||
|
600YL-62A |
2280 |
35.9 |
630 |
|
|
5440+965N |
|
2850 |
31.6 |
|||||
|
3249 |
27.8 |
|||||
|
600YL-62B |
2160 |
68.5 |
560 |
|
|
5440+965N |
|
2700 |
61.9 |
|||||
|
3078 |
56.6 |
|||||
|
700YL-20 |
3420 |
61.8 |
400 |
|
|
|
|
3900 |
55.9 |
|||||
|
4380 |
51.1 |
|||||
|
700YL-20A |
3249 |
55.5 |
315 |
|
|
|
|
3705 |
50.1 |
|||||
|
4161 |
45.8 |
|||||
If you cannot find the required specifications or model in our product range, please contact us at any time. Our technical specialists will provide prompt model selection assistance and a customized technical solution.
Hot Tags: multistage vertical sump pumps, China multistage vertical sump pumps manufacturers, factory