Product Overview
The LHY Molten Sulfur Vertical Sump Pump is a low-flow, high-head, vertical, jacketed sump pump. Developed for the process requirements of the sulfuric acid industry, it is used to convey molten sulfur at 130–158°C in sulfur-burning sulfuric acid plants of various capacities. It may also be used in other high-temperature chemical processes requiring heat tracing and low flow with high head.
The pump is designed for a combination of very high head, very low flow and very low specific speed-conditions that conventional centrifugal pumps cannot readily meet. Vortex pumps can be unstable in this operating range. The LHY uses a purpose-developed hydraulic design intended to address these limitations. The manufacturer describes it as a domestic alternative to imported molten sulfur pumps.
Model example: LHY-1/80
LHY: Molten sulfur pump series
1: Flow rate (m³/h)
80: Pump head (m)
Operating principle and construction
The LHY is a vertical, cantilever-type sump pump with axial suction and a single-stage, single-suction centrifugal impeller. The impeller is submerged in molten sulfur, allowing convenient startup. The pump shaft is supported by a ball bearing above the storage tank and a sliding bearing immersed in the sulfur. The pumped sulfur lubricates the sliding bearing.
Product configurations
Depending on the medium and its solidification behavior, the series is available in three configurations:
Basic type: For media with a relatively low melting point that solidify soon after shutdown, such as asphalt.
Jacketed type: For media that solidify quickly after shutdown, such as sulfur.
Non-jacketed type: For media with a high melting point or that do not solidify after shutdown, such as molten salts.
Product Features
1. Low-flow, high-head hydraulic performance
The LHY is designed for high head, low flow and very low specific speed. Its head remains relatively constant across a wide range of flow rates. This characteristic suits process duties requiring a pump with a self-regulating response and avoids the operating instability associated with vortex pumps in this service.
2. Comprehensive heating-jacket design
The discharge pipe, pump casing and front cover are fitted with jackets for steam or heat-transfer oil. These jackets help prevent molten sulfur from solidifying during transfer. The outlet elbow, shaft and discharge pipe also have heating provisions, supporting the safe draining of the pump after shutdown and reducing the risk of sulfur solidifying inside the pump.
3. Star-shaped impeller for stable operation
The impeller has a simple star-shaped design that is convenient to manufacture. Balance holes in the impeller reduce axial thrust, helping support stable, long-term operation.
4. Cantilevered submerged design for easy startup
The vertical cantilever arrangement typically uses axial suction, with the impeller submerged in molten sulfur. This enables startup without a foot valve or vacuum priming.
5. Efficient, stable operation
The pump uses a hydraulic design intended to provide stable performance, high efficiency, low vibration and noise, and long service life. The manufacturer also cites reduced maintenance requirements and operating costs.
6. Simple construction and convenient maintenance
Main components include the pump casing, impeller, front cover, shaft, elbow, discharge pipe, intermediate pipe, baseplate, bearing housing and motor support. The relatively simple construction is intended to make inspection and maintenance straightforward.
7. Material options for different media
For molten sulfur, the standard material is 1Cr18Ni9Ti (321 stainless steel). For other chemical duties, materials can be selected from 304, 316, 316L, CD4MCu duplex stainless steel, J-1 (UB-6), and Hastelloy B or C, depending on the medium.
8. Explosion-proof motor options
For molten sulfur and other flammable media, a YB-series explosion-proof motor is generally specified. Other motor types may be selected according to the user's requirements and site conditions.
9. Custom configurations
Installation dimensions, submergence depth, connection sizes and heating arrangements can be customized to suit the installation.
Applications
The LHY is used to convey molten sulfur and other hot media that require heat tracing. Typical applications include:
- Sulfur-burning sulfuric acid production: Transfer of molten sulfur at 130–158°C, including use as a refined sulfur pump, filter-aid pump or process sulfur-transfer pump.
- Pyrite-based sulfuric acid production: Molten sulfur transfer in sulfuric acid plants.
- Petroleum refining and sulfur recovery: Transfer of molten sulfur from sulfur-recovery units.
- Coal chemical and sulfur-recovery processes: Molten sulfur transfer in coal gasification, coal liquefaction and related processes.
- Sulfur granulation: Supply and transfer of molten sulfur in granulation systems.
- Fertilizer production: High-temperature transfer of sulfur-bearing process media.
- Other heated services: Hot, insulated transfer of neutral or corrosive media in suitable applications.
Technical Specifications
1. Design Standards
The product is designed in accordance with ISO 2858 and GB 5656. Its performance is stated to be comparable to advanced products in the same international category. Non-standard models can be designed and manufactured to user-specified requirements.
2. Construction and Operating Principle
The LHY is a vertical, single-stage, single-suction, cantilever-type centrifugal sump pump with axial suction. The pump casing, intermediate pipe, discharge pipe, baseplate, bearing housing and motor support are bolted together and mounted on the vessel through the baseplate.
The shaft is supported by a rolling bearing above the tank and a sliding guide bearing immersed in the sulfur. The pumped sulfur lubricates the sliding bearing.
For submergence depths greater than 2 m, an intermediate bearing is required. To prevent excessive sliding-bearing temperature, the specified maximum pump speeds are 1,500 r/min at 50 Hz and 1,800 r/min at 60 Hz. For deep installations, a compact discharge-pipe and shaft arrangement can be used to maintain thermal stability and reduce the tank opening size.
All pumps use a double-volute design to reduce radial forces and sliding-bearing wear, with the aim of extending mean time between failures. Multistage impellers can be supplied for special duties requiring higher head at low speed.
3. Heating System
Heating is provided by low-pressure steam or heat-transfer oil circulating through the jacket cavity. The stated temperature-control range is 130–160°C.
Molten sulfur flows readily and has relatively low viscosity within this range. Below 130°C or above 160°C, its viscosity increases, which can impair flow through the pump or piping and may cause blockage. Heating-medium connections are designed to standard practices; steam or heat-transfer oil can be selected according to site conditions.
4. Wetted-Part Materials
- Molten sulfur, standard service: 1Cr18Ni9Ti (321 stainless steel)
- General corrosive chemical service: 304 (0Cr18Ni9)
- Chloride-containing or more demanding service: 316 (0Cr18Ni12Mo2) or 316L (00Cr18Ni12Mo2)
- Severe corrosion service: CD4MCu duplex stainless steel, Hastelloy B or C, J-1 (UB-6), or 20Cb3, as required
5. Operating Conditions
- Flow rate (Q): 0.1–400 m³/h across the series
- Head (H): 2–200 m, depending on the series
- Speed (n): 1,450 or 2,900 r/min listed; recommended speed is no higher than 1,500 r/min at 50 Hz
- Design pressure: ≤1.6 MPa
- Medium temperature: 130–158°C standard; special manufacturing is stated to allow temperatures up to 550°C
- Submergence depth (L): 0.5–6 m; custom depths available. An intermediate bearing is required above 2 m.
- Explosion protection: YB-series explosion-proof motor or another specified motor configuration
6. Installation Requirements
Mount the pump vertically on the vessel through its baseplate and connect the discharge piping. During operation, the liquid level must remain above the impeller centerline. The guide bearing relies on the pumped medium for lubrication. Do not operate the pump when the liquid level is below the impeller.
7. Operating Precautions
a. Before starting, ensure that the pump is submerged and that the liquid level is above the impeller centerline.
b. Start the pump in the direction shown on the pump. The source specifies counterclockwise rotation when viewed from the motor end. Do not operate the pump in reverse.
c. After shutdown, if ambient temperatures are low, keep the heating system operating as required or drain the pump promptly to prevent sulfur from solidifying and blocking the pump or piping.
d. For special media, provide the medium's name, temperature, concentration, density and viscosity so the manufacturer can select appropriate materials and configuration.
e. In hazardous areas, select the motor in accordance with the required explosion-protection rating.
Structural Drawings

Performance Data Tables
|
Model |
Flow rate (m³/h) |
Head (m) |
Speed (r/min) |
Motor power (kW) |
Efficiency (%) |
NPSH required (m) |
Submergence depth (m) |
Suitable temperature (°C) |
|
LHY-0.32/80 |
0.32 |
80 |
2900 |
2.2 |
- |
- |
1.0 ~ 3.0 |
≤ 550 |
|
LHY-0.32/120 |
0.32 |
120 |
2900 |
4 |
- |
- |
1.0 ~ 3.0 |
≤ 550 |
|
LHY-1/80 |
1 |
80 |
2900 |
4 |
- |
- |
1.0 ~ 3.0 |
≤ 550 |
|
LHY-1/120 |
1 |
120 |
2900 |
5.5 |
- |
- |
1.0 ~ 3.0 |
≤ 550 |
|
LHY-2/80 |
2 |
80 |
2900 |
3 |
- |
- |
1.0 ~ 3.0 |
≤ 550 |
|
LHY-2/120 |
2 |
120 |
2900 |
5.5 |
- |
- |
1.0 ~ 3.0 |
≤ 550 |
|
LHY-3/80 |
3 |
80 |
2900 |
5.5 |
- |
- |
1.0 ~ 3.0 |
≤ 550 |
|
LHY-3/120 |
3 |
120 |
2900 |
7.5 |
- |
- |
1.0 ~ 3.0 |
≤ 550 |
|
LHY-5/80 |
5 |
80 |
2900 |
7.5 |
- |
- |
1.0 ~ 3.0 |
≤ 550 |
|
LHY-5/120 |
5 |
120 |
2900 |
11 |
- |
- |
1.0 ~ 3.0 |
≤ 550 |
|
LHY-10/80 |
10 |
80 |
2900 |
15 |
- |
- |
1.0 ~ 3.0 |
≤ 550 |
|
LHY-15/80 |
15 |
80 |
2900 |
22 |
- |
- |
1.0 ~ 3.0 |
≤ 550 |
|
LHY-20/80 |
20 |
80 |
2900 |
30 |
- |
- |
1.0 ~ 3.0 |
≤ 550 |
|
LHY-25/80 |
25 |
80 |
2900 |
37 |
- |
- |
1.0 ~ 3.0 |
≤ 550 |
|
LHY-30/80 |
30 |
80 |
2900 |
37 |
- |
- |
1.0 ~ 3.0 |
≤ 550 |
|
LHY-50/80 |
50 |
80 |
2900 |
55 |
- |
- |
1.0 ~ 3.0 |
≤ 550 |
|
LHY-80/40 |
80 |
40 |
2900 |
45 |
- |
- |
1.0 ~ 3.0 |
≤ 550 |
|
LHY-100/40 |
100 |
40 |
1450 |
55 |
- |
- |
1.0 ~ 3.0 |
≤ 550 |
|
25LHY-10A |
3.6 |
10 |
2900 |
2.2 |
39 |
- |
0.5 ~ 2.5 |
≤ 200 |
|
25LHY-15A |
3.6 |
15 |
2900 |
2.2 |
41 |
- |
0.5 ~ 2.5 |
≤ 200 |
|
25LHY-20A |
5 |
20 |
2900 |
3 |
41 |
- |
0.5 ~ 2.5 |
≤ 200 |
|
25LHY-25A |
7 |
25 |
2900 |
3 |
45 |
- |
0.5 ~ 2.5 |
≤ 200 |
|
32LHY-20A |
10 |
20 |
2900 |
4 |
43 |
- |
0.5 ~ 2.5 |
≤ 200 |
|
40LHY-25A |
15 |
25 |
2900 |
4 |
45 |
- |
0.5 ~ 2.5 |
≤ 200 |
|
50LHY-20A |
25 |
20 |
2900 |
4 |
54 |
- |
0.5 ~ 2.5 |
≤ 200 |
|
65LHY-25A |
32 |
25 |
2900 |
5.5 |
64 |
- |
0.5 ~ 2.5 |
≤ 200 |
|
65LHY-30A |
25 |
30 |
2900 |
7.5 |
59 |
- |
0.5 ~ 2.5 |
≤ 200 |
|
80LHY-25A |
50 |
25 |
2900 |
7.5 |
64 |
- |
0.5 ~ 2.0 |
≤ 200 |
|
80LHY-30A |
50 |
30 |
2900 |
11 |
58 |
- |
0.5 ~ 2.0 |
≤ 200 |
|
LHY32-200 |
12.5 |
50 |
2900 |
7.5 |
- |
- |
1.0 ~ 3.0 |
120 ~ 160 |
If you cannot find the required specifications or model in our product range, please contact us at any time. Our technical specialists will provide prompt model selection assistance and a customized technical solution.