Product Overview
1. HFY Long-Shaft Vertical Sump Pump
The HFY corrosion-resistant sump pump is a vertical, single-stage centrifugal pump. Its designation, rated performance points and flange connection dimensions are equivalent to those specified in ISO 2858, while its technical requirements follow ISO 5199. Developed from the conventional FY corrosion-resistant sump pump, the HFY incorporates technology from comparable Sulzer products.
The HFY is suitable for conveying weak acids, alkalis, salt solutions, beverages, oils, organic solvents and other corrosive liquids. Wetted-part materials are available in FRPP, F26, F46, UHMWPE, chlorinated polyether and other options. A non-clogging design is also available as the HFYW series, derived from the HFY.
2. IHY Stainless-Steel Vertical Sump Pump
The IHY is a stainless-steel vertical sump pump designed in accordance with national standards. All submerged parts in contact with the liquid are made of stainless steel.
The IHY is the corrosion-resistant model in the ISY/IHY/IWY vertical sump pump series:
ISY: For clean water or non-corrosive liquids with physical and chemical properties similar to water; operating temperature 0–80°C.
IHY: For corrosive liquids; operating temperature 0–80°C.
IWY: For wastewater; operating temperature 0–80°C.
3. Model Designations
Example: 50FY(HY)-25A
- 50: Pump suction inlet diameter (mm)
- F: Corrosion-resistant material designation
- Y: Vertical sump pump designation
- H: Cast-iron or carbon-steel material designation
- 25: Rated head (m) at standard speed with an untrimmed impeller
- A: Impeller-trim designation
Example: 150IHY-50A
- 150: Inlet diameter (mm)
- IHY: Corrosion-resistant vertical sump pump designation
- 50: Design-point head (m)
- A: Impeller-trim designation
Product Features
1. Direct vertical installation reduces civil-work costs
The pump is installed vertically and directly on the vessel containing the pumped medium. Its compact installation requires no additional floor space, helping reduce infrastructure costs.
2. No mechanical seal for leak-free operation
The pump eliminates the mechanical seal, avoiding the frequent maintenance associated with seal wear in other sump pumps. This helps reduce operating costs and improve productivity.
The working section is submerged, so the pump can start without priming or evacuation. Once the liquid level is above the pump casing, no separate filling operation is required.
3. Dual-balanced impeller options for different media
A centrifugal, closed dual-balanced impeller is available for clean liquids without solid particles. It provides high efficiency with very low vibration and noise.
An open dual-balanced impeller is available for dirty liquids containing solid particles or short fibers. It supports stable operation and helps resist clogging.
4. Low-speed operation for extended service life
The HFY operates at a standard low speed of 1,450 r/min, half the 2,900 r/min speed used by some other domestic manufacturers. The lower speed reduces material fatigue and wear. The manufacturer reports a service life increase of 4–5 times compared with higher-speed operation.
The pump uses an API 610 hydraulic model, providing high efficiency, energy savings and reliable performance.
5. Imported bearings for stable, reliable operation
Imported rolling and sliding bearings are used to improve operating stability and reliability. The design life of each bearing type is 3–5 years.
6. Long-shaft coupling for submergence depths up to 12 m
The advanced shaft-coupling arrangement improves operating stability and addresses alignment issues that can arise when multiple shaft sections are connected. The design allows submergence depths of up to 12 m and is intended for continuous, trouble-free operation.
7. Stainless-steel construction for the IHY
All submerged, liquid-contacting parts of the IHY are made of stainless steel. The design offers broad corrosion resistance, high efficiency, a secure shaft connection and convenient disassembly. The pump can begin conveying liquid without priming.
8. Flexible coupling drive for smooth operation
The motor directly drives the pump through a claw-type flexible coupling. Viewed from the motor end, the pump rotates clockwise. Axial and radial forces generated during operation are supported by rolling and sliding bearings, respectively, for quiet operation.
9. Self-lubricated or externally lubricated sliding bearings
The sliding bearings can use external lubrication or self-lubrication, depending on the medium and site conditions.
For media containing small particles, clean flushing liquid can be introduced externally to lubricate the sliding bearings and carry away frictional heat.
For clean media, a line can be connected from the pump discharge flange to provide self-flushing lubrication.
10. Convenient inspection and maintenance
To inspect or replace the impeller, close the discharge valve, remove the flange and baseplate connection bolts, then use lifting equipment to raise the pump out of the vessel. Reassemble in the reverse order, taking care to maintain concentricity of the components on the shaft.
Applications
HFY and IHY vertical sump pumps are used across a range of industries and process duties:
- Petroleum and petrochemical industries: Transfer of corrosive acids, alkalis, salt solutions and organic solvents, including corrosive process fluids in refineries and petrochemical plants. HFY/HY/IHY-type pumps are also used in the petroleum, chemical, pharmaceutical, pulp and paper, metallurgical and wastewater-treatment industries.
- Pharmaceutical industry: Transfer of corrosive reaction media used in pharmaceutical intermediate and active ingredient production.
- Metallurgical industry: Transfer of corrosive media such as electrolytes and pickling solutions in non-ferrous metal production.
- Pulp and paper industry: Transfer of pulp-bleaching liquor and other corrosive papermaking chemicals.
- Power generation: Plant water supply, cooling-water circulation and condensate recovery.
- Environmental protection and water treatment: Industrial wastewater treatment, acid and alkali wastewater neutralization, acid dosing, and wastewater transfer at heating plants and wastewater-treatment facilities.
- Food and beverage industries: Transfer of beverages, oils and other food-processing liquids subject to hygienic requirements.
- Cement and building-materials industries: Transfer of clean or particle-laden liquids in cement plants, steelworks and similar facilities.
- Coal chemical and low-temperature applications: Transfer of coal-processing fluids and low-temperature media.
Technical Specifications
1. Design Standards
The HFY/IHY sump pumps use designations, rated performance points and flange connection dimensions equivalent to ISO 2858 for 16-bar-class end-suction centrifugal pumps. Their technical requirements follow ISO 5199. Some products are manufactured in accordance with GB/T 5656-94, Technical Specifications for Single-Stage, Single-Suction Chemical Centrifugal Pumps.
The hydraulic performance of the HFY high-efficiency, energy-saving long-shaft sump pump series conforms to the API standard. Product quality is stated to be comparable to that of similar international products.
2. Construction and Operating Principle
The HFY/IHY is a vertical, single-stage, single-suction, long-shaft centrifugal sump pump. The motor drives the pump shaft directly through a claw-type flexible coupling.
The pump casing, cover, impeller and other wetted components operate submerged in the tank liquid. The impeller is mounted at the end of the shaft, keeping the rolling bearings away from the liquid and protecting the upper components from corrosion by the pumped medium. During operation, the submerged impeller draws liquid through the suction inlet, pressurizes it and discharges it upward through the discharge pipe.
Viewed from the motor end, the pump rotates clockwise.
The submerged length is made to suit the required vessel insertion depth. For submerged lengths greater than 2 m, a shaft-extension coupling is required. A sliding bearing is fitted at the connection between the pump casing and shaft extension, and the clearances in the rotating assembly can be adjusted. The above-liquid section uses radial and thrust ball bearings; the submerged section uses sliding bearings.
3. Wetted-Part Material Selection
|
Pump type |
Material options |
Typical service |
|
HFY |
F46 (fluorinated ethylene propylene), F26, FRPP (reinforced polypropylene), UHMWPE (ultra-high-molecular-weight polyethylene), chlorinated polyether |
Weak acids, alkalis, salts, beverages, oils and organic solvents. Operating temperature not above 100°C. Can handle corrosive media containing small amounts of solids or abrasive particles. |
|
IHY |
1Cr18Ni9Ti (code B), 1Cr18Ni12Mo2Ti (code M), 304, 304L, 316, 316L |
Corrosive liquids without solid particles; typical operating temperature 0–105°C. |
|
FY |
HT20-40 cast iron (code H), ZL102 aluminum-silicon alloy (code FYL) |
Non-corrosive or mildly corrosive media. |
For pumped-medium temperatures from −20°C to 0°C or 105°C to 180°C, heating or cooling jackets and low- or high-temperature wear-resistant guide bearings may be required. Specify these conditions when ordering.
4. Operating Conditions
- Flow rate (Q): 1.6–2,600 m³/h for the HFY standard range; 3–460 m³/h for the FYH series
- Head (H): 5–132 m for the HFY series; 3–80 m for the FYH series
- Speed (n): 1,450 or 2,900 r/min; 1,450 r/min is recommended for longer service life
- Design pressure: ≤1.6 MPa
- Medium temperature: −40°C to +180°C; standard range 0–105°C. A heating jacket is used for low-temperature service.
- Submergence depth (L): 0.5–12 m; standard depth ≤4 m, with custom extensions available up to 12 m
- Motor power: 0.75–160 kW, selected based on actual operating conditions
- Suction inlet diameter: 25–150 mm, depending on model
5. Sealing and Bearings
a. No mechanical seal:
The working section operates submerged, eliminating the conventional mechanical seal and removing the associated dynamic-seal leakage point. No rotary dynamic seal is installed in the submerged section; the above-liquid arrangement prevents the pumped medium from leaking externally.
b. Sliding-bearing lubrication:
Sliding bearings can use self-flushing or external flushing. For clean media, a line can be connected from the pump discharge flange to provide self-flushing lubrication. For media containing small amounts of particles, clean external flushing liquid lubricates the bearings, carries away frictional heat and helps prevent solids from entering the bearing surfaces.
c. Above-liquid bearing system:
Radial and thrust ball bearings in the above-liquid section support the radial and axial loads generated during pump operation.
6. Installation and Maintenance
Install the pump vertically on the mounting flange above the liquid-storage vessel and connect the discharge line. Maintain a clearance between the pump casing and vessel wall of more than 2.5 times the pump inlet diameter. The distance from the suction inlet to the vessel bottom should be 2–3 times the inlet diameter.
Support the discharge piping independently; do not allow its weight to rest on the pump. Before starting, check that the motor's direction of rotation matches the direction indicated on the pump.
After installation:
Turn the coupling by hand to confirm that it rotates freely.
Check the concentricity of the pump and motor shafts. The maximum left-to-right difference between the outer circumferences of the upper and lower coupling halves must not exceed 0.1 mm.
Maintain a coupling-face gap of 1–2.5 mm.
After starting, open the discharge gate valve gradually to the required operating position.
During operation, monitor the pump and motor. Bearing temperature rise should not exceed 75°C, and the bearing housing should contain sufficient grease.
Before prolonged winter shutdown, drain the liquid from the pump to prevent freeze damage. For special media, provide the medium's name, temperature, concentration, density, viscosity, solids content and particle size so that suitable materials and configurations can be selected.
Structural Drawings

Performance Data Tables
|
Model |
Discharge diameter (mm) |
Flow rate (m³/h) |
Head (m) |
Speed (r/min) |
Shaft power (kW) |
Motor power, specific gravity = 1.00 (kW) |
|
IHY50-32-125 |
32 |
12.5 |
20 |
2900 |
1.33 |
2.2 |
|
IHY50-32-125A |
32 |
11.3 |
16.4 |
2900 |
0.99 |
1.5 |
|
IHY50-32-160 |
32 |
12.5 |
32 |
2900 |
2.37 |
3 |
|
IHY50-32-160A |
32 |
11.3 |
26.4 |
2900 |
1.85 |
3 |
|
IHY50-32-200 |
32 |
12.5 |
50 |
2900 |
4.36 |
5.5 |
|
IHY50-32-200A |
32 |
11.3 |
41 |
2900 |
3.32 |
4 |
|
IHY50-32-250 |
32 |
12.5 |
80 |
2900 |
8.25 |
11 |
|
IHY50-32-250A |
32 |
11.7 |
70 |
2900 |
6.97 |
11 |
|
IHY50-32-250B |
32 |
11 |
62 |
2900 |
6.19 |
7.5 |
|
IHY65-50-125 |
50 |
25 |
20 |
2900 |
2.2 |
3 |
|
IHY65-50-125A |
50 |
22.7 |
16.5 |
2900 |
1.67 |
2.2 |
|
IHY65-50-160 |
50 |
25 |
32 |
2900 |
3.82 |
5.5 |
|
IHY65-50-160A |
50 |
22.7 |
26.5 |
2900 |
2.93 |
4 |
|
IHY65-40-200 |
40 |
25 |
50 |
2900 |
6.55 |
11 |
|
IHY65-40-200A |
40 |
22.7 |
41 |
2900 |
5.07 |
7.5 |
|
IHY65-40-250 |
40 |
25 |
80 |
2900 |
11.84 |
15 |
|
IHY65-40-250A |
40 |
23.4 |
74.8 |
2900 |
10.59 |
15 |
|
IHY65-40-315 |
40 |
25 |
125 |
2900 |
21.83 |
30 |
|
IHY65-40-315A |
40 |
23.4 |
109.5 |
2900 |
18.37 |
30 |
|
IHY80-65-125 |
65 |
50 |
20 |
2900 |
3.95 |
5.5 |
|
IHY80-65-125A |
65 |
45.3 |
16.5 |
2900 |
3.04 |
4 |
|
IHY80-65-160 |
65 |
50 |
32 |
2900 |
6.5 |
11 |
|
IHY80-65-160A |
65 |
45.3 |
26.5 |
2900 |
4.95 |
7.5 |
|
IHY80-50-200 |
50 |
50 |
50 |
2900 |
10.81 |
15 |
|
IHY80-50-200A |
50 |
45.3 |
41 |
2900 |
8.16 |
11 |
|
IHY80-50-250 |
50 |
50 |
80 |
2900 |
19.11 |
30 |
|
IHY80-50-250A |
50 |
46.8 |
70 |
2900 |
15.93 |
22 |
|
IHY80-50-315 |
50 |
50 |
125 |
2900 |
32.73 |
45 |
|
IHY80-50-315A |
50 |
46.8 |
109.5 |
2900 |
27.36 |
37 |
|
IHY100-80-125 |
80 |
100 |
20 |
2900 |
7.47 |
11 |
|
IHY100-80-125A |
80 |
91.8 |
16.8 |
2900 |
5.92 |
7.5 |
|
IHY100-80-160 |
80 |
100 |
32 |
2900 |
11.94 |
15 |
|
IHY100-80-160A |
80 |
90.8 |
26.5 |
2900 |
9.23 |
11 |
|
IHY100-65-200 |
65 |
100 |
50 |
2900 |
18.65 |
30 |
|
IHY100-65-200A |
65 |
90.8 |
41 |
2900 |
14.28 |
22 |
|
IHY100-65-250 |
65 |
100 |
80 |
2900 |
32.03 |
45 |
|
IHY100-65-250A |
65 |
93.5 |
70 |
2900 |
26.6 |
37 |
|
IHY100-65-315 |
65 |
100 |
125 |
2900 |
54.88 |
75 |
|
IHY100-65-315A |
65 |
93.5 |
109.5 |
2900 |
45.71 |
55 |
|
IHY125-100-200 |
100 |
200 |
50 |
2900 |
35.35 |
45 |
|
IHY125-100-200A |
100 |
181.6 |
41 |
2900 |
27.03 |
37 |
|
IHY125-100-250 |
100 |
200 |
80 |
2900 |
60.49 |
75 |
|
IHY125-100-250A |
100 |
187 |
70 |
2900 |
50.19 |
55 |
|
IHY125-100-315 |
100 |
200 |
125 |
2900 |
100.06 |
132 |
|
IHY125-100-315A |
100 |
187 |
109.5 |
2900 |
83.21 |
110 |
|
IHY125-100-400 |
100 |
100 |
50 |
1450 |
21.96 |
30 |
|
IHY150-125-250 |
125 |
200 |
20 |
1450 |
14.16 |
18.5 |
|
IHY150-125-315 |
125 |
200 |
32 |
1450 |
24.2 |
30 |
|
IHY150-125-400 |
125 |
200 |
50 |
1450 |
38.89 |
55 |
|
IHY200-150-250 |
150 |
400 |
20 |
1450 |
27.57 |
37 |
|
IHY200-150-315 |
150 |
400 |
32 |
1450 |
45.24 |
55 |
|
IHY200-150-400 |
150 |
400 |
50 |
1450 |
69.8 |
90 |
|
25HFY-16 |
25 |
3.6 |
16 |
2900 |
0.713 |
1.5 |
|
25HFY-16A |
25 |
3.27 |
13 |
2900 |
0.713 |
1.5 |
|
25HFY-25 |
25 |
3.6 |
25 |
2900 |
1.16 |
2.2 |
|
25HFY-25A |
25 |
3.27 |
20 |
2900 |
1.16 |
2.2 |
|
25HFY-41 |
25 |
3.6 |
41 |
2900 |
2.51 |
4 |
|
25HFY-41A |
25 |
3.27 |
33 |
2900 |
2.51 |
3 |
|
40HFY-16 |
32 |
7.2 |
16 |
2900 |
0.78 |
2.2 |
|
40HFY-16A |
32 |
6.55 |
13 |
2900 |
0.78 |
1.5 |
|
40HFY-26 |
32 |
7.2 |
26 |
2900 |
1.45 |
3 |
|
40HFY-26A |
32 |
6.55 |
21 |
2900 |
1.45 |
3 |
|
40HFY-40 |
32 |
7.2 |
40 |
2900 |
2.53 |
5.5 |
|
40HFY-40A |
32 |
6.55 |
32 |
2900 |
2.53 |
5.5 |
|
50HFY-16 |
40 |
14.4 |
16 |
2900 |
1.18 |
3 |
|
50HFY-16A |
40 |
13.1 |
13 |
2900 |
1.18 |
3 |
|
50HFY-25 |
40 |
14.4 |
25 |
2900 |
1.96 |
4 |
|
50HFY-25A |
40 |
13.1 |
20 |
2900 |
1.96 |
3 |
|
50HFY-40 |
40 |
14.4 |
40 |
2900 |
3.73 |
7.5 |
|
50HFY-40A |
40 |
13.1 |
33 |
2900 |
3.73 |
5.5 |
|
65HFY-16 |
50 |
28.8 |
16 |
2900 |
2.16 |
4 |
|
65HFY-16A |
50 |
26.2 |
13 |
2900 |
2.16 |
3 |
|
65HFY-25 |
50 |
28.8 |
25 |
2900 |
3.56 |
5.5 |
|
65HFY-25A |
50 |
26.2 |
21 |
2900 |
3.56 |
5.5 |
|
65HFY-40 |
50 |
28.8 |
40 |
2900 |
6.04 |
11 |
|
65HFY-40A |
50 |
26.2 |
33 |
2900 |
6.04 |
11 |
|
80HFY-15 |
65 |
54 |
15 |
2900 |
3.34 |
7.5 |
|
80HFY-15A |
65 |
49.1 |
12 |
2900 |
3.34 |
7.5 |
|
80HFY-24 |
65 |
54 |
24 |
2900 |
5.43 |
11 |
If you cannot find the required specifications or model in our product range, please contact us at any time. Our technical specialists will provide prompt model selection assistance and a customized technical solution.
Hot Tags: hfy–ihy vertical sump pumps, China hfy–ihy vertical sump pumps manufacturers, factory