Product Overview
The IH pump is a single-stage, single-suction, overhung chemical centrifugal pump developed as an energy-saving successor to the F-type corrosion-resistant centrifugal pump. Its designation, rated performance and installation dimensions are based on ISO 2858:1975(E), and it is manufactured in accordance with GB 5662-85.
The pump is horizontally installed, with axial suction and radial discharge. Its back-pull-out design uses an extended coupling, allowing the rotating assembly to be withdrawn for maintenance without disconnecting the suction and discharge piping.
The hydraulic design is optimized to improve efficiency. Compared with traditional F-type pumps, the source states an average efficiency increase of 3–5%.
Product Features
1. Efficient hydraulic design
The casing and impeller are made using precision-casting methods, including investment casting or lost-foam casting, to provide smooth flow passages. The impeller is designed with computational fluid dynamics (CFD), supporting efficient operation and cavitation performance.
2. Modular bearing bracket
The bearing bracket uses a standardized modular design. Across the series, only four to five bracket types are required, helping reduce spare-parts inventory and maintenance costs.
3. Multiple shaft-seal options
A single mechanical seal is standard. Depending on the medium and operating conditions, the pump can also be supplied with:
- Packing seal
- Double balanced or unbalanced mechanical seal
- Metal bellows mechanical seal
The seal chamber complies with ISO 3069, and established flushing and cooling arrangements are available.
4. Corrosion-resistant materials
Wetted components can be made from materials including 304, 316L and 904L stainless steel, as well as duplex stainless steel. These options support handling of acids, alkalis, salt solutions and liquids where product contamination must be avoided.
5. Reinforced construction
The casing has reinforcing ribs. Larger casings use a double-volute design to help balance radial forces, supporting stable operation with low vibration and noise.
Applications
The IH pump is intended for corrosive or contamination-sensitive liquids that contain no solid particles and have a viscosity similar to water. Typical applications include:
Petrochemical and chemical industries:
Acids, alkalis, salt solutions and organic solvents.
01
Fine chemicals and pharmaceuticals:
Pharmaceutical intermediates and chemical additives.
02
Environmental protection and water treatment:
Industrial wastewater, seawater desalination and power-plant desulfurization wastewater.
03
Metallurgy and paper production:
Pickling solutions, black liquor and other corrosive liquids.
04
Food and power industries:
Food-processing liquids, condensate recovery and boiler-feed water.
05
Application note:
The source describes the pump as suitable for liquids without solids and with water-like viscosity, but also lists black liquor among its applications. Black liquor properties can vary substantially. Confirm its viscosity, solids content, temperature and compatibility with the selected pump before specifying this service.
Technical Specifications
Design Standard
ISO 2858: End-suction centrifugal pump standard
Operating Conditions
- Maximum operating pressure: 1.6 MPa
- Standard medium temperature: −20°C to +105°C
- Special configurations: +180°C to +280°C, as stated in the source; availability depends on cooling provisions, seal type and pump configuration
3. Pump Configuration
Single-stage, single-suction, overhung pump with a back-pull-out design and foot-mounted casing.
4. Direction of Rotation
Viewed from the motor end toward the pump, the impeller rotates clockwise.
5. General Performance Range
- Flow rate (Q): 3.4–1,080 m³/h, covering the basic series and trimmed-impeller versions
- Head (H): 3.7–132 m
- Speed (n): 2,900 / 1,450 r/min; direct motor drive or variable-frequency control
- Operating pressure: ≤1.6 MPa standard design pressure
- Medium temperature: −20°C to +105°C standard; 180°C–280°C with special configurations, as stated
- Inlet diameter: 50–200 mm
- Motor power: 0.55–160 kW, selected according to the medium's density and viscosity
6. Model Designation
- Example: IH50-32-125A
- IH: Single-stage, single-suction chemical centrifugal pump
- 50: Suction diameter, 50 mm
- 32: Discharge diameter, 32 mm
- 125: Nominal impeller diameter, 125 mm
- A: First impeller trim
Structural Drawings

Performance Data Tables
|
Model |
Speed (r/min) |
Flow rate Q (m³/h) |
Head H (m) |
Efficiency η (%) |
Shaft power (kW) |
Motor power (kW) |
NPSHr (m) |
Pump weight (kg) |
|
IH50-32-125 |
2900 |
12.5 |
20 |
51 |
1.33 |
2.2 |
2 |
45 |
|
1450 |
6.3 |
5 |
45 |
0.19 |
0.55 |
2 |
45 |
|
|
IH50-32-125A |
2900 |
11.3 |
16.4 |
50 |
1.01 |
1.5 |
2 |
45 |
|
1450 |
5.7 |
4.1 |
43 |
0.15 |
0.55 |
2 |
45 |
|
|
IH50-32-160 |
2900 |
12.5 |
32 |
46 |
2.37 |
3 |
2 |
49 |
|
1450 |
6.3 |
8 |
40 |
0.34 |
0.55 |
2 |
49 |
|
|
IH50-32-160A |
2900 |
11.3 |
26.4 |
44 |
1.85 |
3 |
2 |
49 |
|
1450 |
5.7 |
6.6 |
37.1 |
0.28 |
0.55 |
2 |
49 |
|
|
IH50-32-200 |
2900 |
12.5 |
50 |
39 |
4.36 |
5.5 |
2 |
59 |
|
1450 |
6.3 |
12.5 |
33 |
0.65 |
1.1 |
2 |
59 |
|
|
IH50-32-200A |
2900 |
11.3 |
41 |
38 |
3.32 |
4 |
2 |
59 |
|
1450 |
5.7 |
10.3 |
31 |
0.52 |
0.75 |
2 |
59 |
|
|
IH50-32-250 |
2900 |
12.5 |
80 |
33 |
8.25 |
11 |
2 |
92 |
|
1450 |
6.3 |
20 |
27 |
1.27 |
2.2 |
2 |
92 |
|
|
IH50-32-250A |
2900 |
11.7 |
70 |
32 |
6.97 |
11 |
2 |
92 |
|
1450 |
5.9 |
17.5 |
25 |
1.12 |
1.5 |
2 |
92 |
|
|
IH50-32-250B |
2900 |
11 |
62 |
30 |
6.19 |
7.5 |
2 |
92 |
|
IH65-50-125 |
2900 |
25 |
20 |
62 |
2.2 |
3 |
2 |
46 |
|
1450 |
12.5 |
5 |
55 |
0.31 |
0.55 |
2 |
46 |
|
|
IH65-50-125A |
2900 |
22.7 |
16.5 |
61 |
1.67 |
2.2 |
2 |
46 |
|
1450 |
11.3 |
4.1 |
54 |
0.23 |
0.55 |
2 |
46 |
|
|
IH65-50-160 |
2900 |
25 |
32 |
57 |
3.82 |
5.5 |
2 |
52 |
|
1450 |
12.5 |
8 |
51 |
0.53 |
0.75 |
2 |
52 |
|
|
IH65-50-160A |
2900 |
22.7 |
26.5 |
56 |
2.93 |
4 |
2 |
52 |
|
1450 |
11.3 |
6.6 |
49.6 |
0.41 |
0.55 |
2 |
52 |
|
|
IH65-40-200 |
2900 |
25 |
50 |
52 |
6.55 |
11 |
2 |
62 |
|
1450 |
12.5 |
12.5 |
46 |
0.93 |
1.5 |
2 |
62 |
|
|
IH65-40-200A |
2900 |
22.7 |
41 |
50 |
5.07 |
7.5 |
2 |
62 |
|
1450 |
11.3 |
10.3 |
44 |
0.72 |
1.1 |
2 |
62 |
|
|
IH65-40-250 |
2900 |
25 |
80 |
46 |
11.84 |
15 |
2 |
98 |
|
1450 |
12.5 |
20 |
39 |
1.75 |
3 |
2 |
98 |
|
|
IH65-40-250A |
2900 |
23.4 |
74.8 |
45 |
10.59 |
15 |
2 |
98 |
|
1450 |
11.7 |
17.5 |
37.9 |
1.47 |
2.2 |
2 |
98 |
|
|
IH65-40-315 |
2900 |
25 |
125 |
39 |
21.83 |
30 |
2 |
115 |
|
1450 |
12.5 |
32 |
33 |
3.3 |
5.5 |
2 |
115 |
|
|
IH65-40-315A |
2900 |
23.4 |
109.5 |
38 |
18.37 |
30 |
2 |
115 |
|
1450 |
11.7 |
28 |
33 |
2.7 |
4 |
2 |
115 |
|
|
IH80-65-125 |
2900 |
50 |
20 |
69 |
3.95 |
5.5 |
3 |
52 |
|
1450 |
25 |
5 |
64 |
0.53 |
0.75 |
2.5 |
52 |
|
|
IH80-65-125A |
2900 |
45.3 |
16.5 |
67 |
3.04 |
4 |
3 |
52 |
|
1450 |
22.7 |
4.1 |
62 |
0.41 |
0.55 |
2.5 |
52 |
|
|
IH80-65-160 |
2900 |
50 |
32 |
67 |
6.5 |
11 |
2.3 |
60 |
|
1450 |
25 |
8 |
62 |
0.88 |
1.5 |
2 |
60 |
|
|
IH80-65-160A |
2900 |
45.3 |
26.5 |
66 |
4.95 |
7.5 |
2.3 |
60 |
|
1450 |
22.7 |
6.6 |
60 |
0.68 |
1.1 |
2 |
60 |
|
|
IH80-50-200 |
2900 |
50 |
50 |
63 |
10.81 |
15 |
2.5 |
72 |
|
1450 |
25 |
12.5 |
57 |
1.49 |
2.2 |
2 |
72 |
|
|
IH80-50-200A |
2900 |
45.3 |
41 |
62 |
8.16 |
11 |
2.5 |
72 |
|
1450 |
22.7 |
10.3 |
55 |
1.16 |
1.5 |
2 |
72 |
|
|
IH80-50-250 |
2900 |
50 |
80 |
57 |
19.11 |
30 |
2.5 |
110 |
|
1450 |
25 |
20 |
52 |
2.62 |
4 |
2 |
110 |
|
|
IH80-50-250A |
2900 |
46.8 |
70 |
56 |
15.93 |
22 |
2.5 |
110 |
|
1450 |
23.4 |
17.5 |
50 |
2.23 |
3 |
2 |
110 |
|
|
IH80-50-315 |
2900 |
50 |
125 |
52 |
32.73 |
45 |
2.5 |
128 |
|
1450 |
25 |
32 |
47 |
4.63 |
7.5 |
2 |
128 |
|
|
IH80-50-315A |
2900 |
46.8 |
109.5 |
51 |
27.36 |
37 |
2.5 |
128 |
|
1450 |
23.4 |
28 |
45 |
3.96 |
5.5 |
2 |
128 |
|
|
IH100-80-125 |
2900 |
100 |
20 |
73 |
7.46 |
11 |
4.3 |
68 |
|
1450 |
50 |
5 |
69 |
0.99 |
1.5 |
2.5 |
68 |
|
|
IH100-80-125A |
2900 |
90.8 |
16.5 |
71 |
5.75 |
7.5 |
4.3 |
68 |
|
1450 |
45.4 |
4.1 |
67 |
0.76 |
1.1 |
2.5 |
68 |
|
|
IH100-80-160 |
2900 |
100 |
32 |
73 |
11.94 |
15 |
4 |
78 |
|
1450 |
50 |
8 |
69 |
1.58 |
2.2 |
2.5 |
78 |
|
|
IH100-80-160A |
2900 |
90.8 |
26.5 |
71 |
9.23 |
11 |
4 |
78 |
|
1450 |
45.4 |
6.6 |
67 |
1.22 |
1.5 |
2.5 |
78 |
|
|
IH100-65-200 |
2900 |
100 |
50 |
73 |
18.65 |
30 |
3.9 |
90 |
|
1450 |
50 |
12.5 |
68 |
2.5 |
4 |
2.5 |
90 |
|
|
IH100-65-200A |
2900 |
90.8 |
41 |
71 |
14.28 |
22 |
3.9 |
90 |
|
1450 |
45.4 |
10.3 |
66 |
1.93 |
3 |
2.5 |
90 |
|
|
IH100-65-250 |
2900 |
100 |
80 |
68 |
32.03 |
45 |
3.6 |
125 |
|
1450 |
50 |
20 |
63 |
4.32 |
7.5 |
2.5 |
125 |
|
|
IH100-65-250A |
2900 |
93.5 |
70 |
67 |
26.6 |
37 |
3.6 |
125 |
|
1450 |
46.8 |
17.5 |
61 |
3.66 |
5.5 |
2.5 |
125 |
|
|
IH100-65-315 |
2900 |
100 |
125 |
62 |
54.88 |
75 |
3.6 |
142 |
|
1450 |
50 |
32 |
58 |
7.51 |
11 |
2.5 |
142 |
|
|
IH100-65-315A |
2900 |
93.5 |
109.5 |
61 |
45.71 |
55 |
3.6 |
142 |
|
1450 |
46.8 |
28 |
56 |
6.37 |
11 |
2.5 |
142 |
|
|
IH125-100-200 |
2900 |
200 |
50 |
77 |
35.35 |
45 |
5 |
98 |
|
1450 |
100 |
12.5 |
73 |
4.66 |
7.5 |
2.8 |
98 |
|
|
IH125-100-200A |
2900 |
181.6 |
41 |
75 |
27.03 |
37 |
5 |
98 |
|
1450 |
90.8 |
10.3 |
71 |
3.59 |
5.5 |
2.8 |
98 |
|
|
IH125-100-250 |
2900 |
200 |
80 |
72 |
60.49 |
75 |
4.5 |
135 |
|
1450 |
100 |
20 |
70 |
7.78 |
15 |
2.5 |
135 |
|
|
IH125-100-250A |
2900 |
187 |
70 |
71 |
50.19 |
55 |
4.5 |
135 |
|
1450 |
93.5 |
17.5 |
68 |
6.55 |
11 |
2.5 |
135 |
|
|
IH125-100-315 |
2900 |
200 |
125 |
68 |
100.06 |
132 |
4.2 |
155 |
|
1450 |
100 |
32 |
65 |
13.4 |
22 |
2.5 |
155 |
|
|
IH125-100-315A |
2900 |
187 |
109.5 |
67 |
83.21 |
110 |
4.2 |
155 |
|
1450 |
93.5 |
28 |
63 |
11.31 |
18.5 |
2.5 |
155 |
|
|
IH125-100-400 |
1450 |
100 |
50 |
62 |
21.96 |
30 |
2.5 |
220 |
|
IH125-100-400A |
1450 |
118 |
43.7 |
61 |
18.24 |
30 |
2.5 |
220 |
|
IH150-125-250 |
1450 |
200 |
22 |
77 |
14.16 |
18.5 |
2.8 |
175 |
|
IH150-125-250A |
1450 |
150 |
10 |
- |
- |
11 |
- |
- |
|
IH150-125-315 |
1450 |
200 |
32 |
72 |
24.2 |
30 |
2.8 |
200 |
|
IH150-125-315A |
1450 |
112 |
32.3 |
62 |
15.92 |
30 |
2.5 |
200 |
|
IH150-125-400 |
1450 |
200 |
50 |
70 |
38.89 |
55 |
2.8 |
260 |
|
IH150-125-400A |
1450 |
187 |
44 |
68 |
32.95 |
45 |
2.8 |
260 |
|
IH200-150-250 |
1450 |
400 |
20 |
79 |
27.57 |
37 |
3.5 |
230 |
|
IH200-150-250A |
1450 |
372 |
17 |
77 |
22.36 |
30 |
3.5 |
230 |
|
IH200-150-315 |
1450 |
400 |
32 |
77 |
45.24 |
75 |
3.5 |
280 |
|
IH200-150-315A |
1450 |
374 |
28 |
75 |
38 |
55 |
3.5 |
280 |
|
IH200-150-400 |
1450 |
400 |
50 |
78 |
69.8 |
90 |
3.8 |
340 |
|
IH200-150-400A |
1450 |
374 |
44 |
76 |
58.94 |
75 |
3.8 |
340 |
If you cannot find the required specifications or model in our product range, please contact us at any time. Our technical specialists will provide prompt model selection assistance and a customized technical solution.
Hot Tags: ih chemical centrifugal pump, China ih chemical centrifugal pump manufacturers, factory