Product Overview
The acid and alkali resistant self-priming pump, commonly known as the "big head pump", is a vertical, sealless, corrosion-resistant self-priming centrifugal pump. The motor is installed on the motor seat above the pump body, while the pump body can be placed directly on the tank or on an external working platform beside the tank.
The pump head is relatively large, which is why it is commonly called a "big head" pump. Inside the enlarged pump head, there is a large-capacity liquid storage chamber and a labyrinth-type gas-liquid separation chamber, forming an external-mixing self-priming system.
Before the first startup, the pump body only needs to be filled with liquid. For subsequent startups, no additional priming is required. The pump can be started directly to draw liquid from below the pump installation level and discharge it to the target location.
All wetted parts are made of corrosion-resistant materials. Main components such as the pump body, impeller and pump cover can be selected according to the characteristics of the medium, including:
- FRPP reinforced polypropylene
- PVDF polyvinylidene fluoride
- PFA / ETFE melt-processable fluoroplastic
- Titanium alloy
- SUS304 / SUS316 stainless steel
The pump adopts a sealless design. There is no mechanical seal or packing seal in the liquid-contact area. The axial and radial forces generated during operation are supported by rolling bearings located above the liquid level. Since there is no dynamic seal in the submerged or liquid-contact section, leakage is fundamentally prevented.
Model Meaning Example
FN-32-20-125
FN - Material code
FN = FRPP
FP = PVDF
FZ = PFA
FT = Titanium alloy
FS = Stainless steel
32 - Pump suction diameter, mm
20 - Pump discharge diameter, mm
125 - Nominal impeller diameter, mm
Some manufacturers also use a flow/head naming method. For example:
FN-100-20 means:
Flow rate: 100 m³/h
Head: 20 m
Product Features
1. "Big Head" Liquid Storage Chamber for Strong Self-Priming Performance
The pump head is enlarged and equipped with a large-capacity liquid storage chamber, which can store sufficient priming liquid.
After the initial priming, no foot valve is required in the pipeline to achieve self-priming. The self-priming height can reach approximately 4–5 meters, with a short self-priming time.
This design is especially suitable for external tank transfer applications where liquids are frequently changed.
2. Sealless Design with No Leakage
The pump has no mechanical seal or packing seal and adopts a sealless structure, fundamentally eliminating the risk of leakage of corrosive liquids.
During operation, the axial and radial forces are supported by rolling bearings located above the liquid level.
3. Wide Selection of Wetted Materials for Various Acid and Alkali Media
The pump can be made of various corrosion-resistant materials, including:
- FRPP reinforced polypropylene
- PVDF polyvinylidene fluoride
- PFA / ETFE melt-processable fluoroplastic
- Titanium alloy
- SUS304 stainless steel
- SUS316 stainless steel
These material options allow the pump to handle a wide range of corrosive applications, from weak acids and alkalis to strong oxidizing acids, hydrofluoric acid, aqua regia and other highly corrosive media.
Final material selection should be confirmed according to the actual medium composition, concentration, temperature and operating conditions.
4. Short-Time Dry Running Capability
Thanks to its sealless design, the pump can tolerate short-time dry running without damage to the pump body or seal components.
This feature makes it suitable for automatic control processes and intermittent operating conditions.
However, long-time dry running is generally not recommended unless confirmed for the specific model and operating condition.
5. Compact Structure and Easy Mobility
The pump has a compact structure and relatively light weight, making it easy to move between different tanks.
One pump can be used alternately for multiple tanks, helping reduce equipment investment.
6. Flexible Installation Options
Multiple installation methods are available:
Directly placed on the top of the tank
Installed on an external working platform beside the tank
Mounted on a mobile trolley for transfer between tanks
This provides flexibility for different site layouts and operating requirements.
7. Easy Maintenance with Few Wearing Parts
The pump has a simple structure and fewer wearing parts. The main wearing components are generally the impeller and pump wear ring.
Maintenance is convenient. In many cases, there is no need to dismantle the pipeline. The pump body can be lifted out as a complete unit for inspection and maintenance.
8. Self-Cooling Function for Some Series
Some PVDF / PFA series pumps have a certain level of dry-running capability and self-cooling performance.
They are suitable for applications involving frequent starts and stops, subject to the specific model design and actual working conditions.
Applications
The acid and alkali resistant self-priming pump, also known as the "big head" self-priming pump, is widely used for circulation, filtration and transfer of various corrosive liquids inside or outside tanks.
Electroplating Industry
Suitable for circulation, filtration and agitation of various electroplating solutions, including:
- Copper plating solution
- Nickel plating solution
- Chrome plating solution
- Zinc plating solution
- Gold plating solution
- Silver plating solution
It can also be used for external transfer of electroplating chemicals from tanks.
Surface Treatment Industry
Used for circulation and transfer of process liquids in:
- Pickling tanks
- Phosphating tanks
- Anodizing tanks
- Electropolishing tanks
- Passivation tanks
PCB and Semiconductor Industry
Applicable for circulation, filtration and external tank transfer of process liquids such as:
- Developer solution
- Etching solution
- Stripping solution
- Electroless copper solution
- Electroless nickel solution
Chemical Industry
Suitable for transferring various corrosive liquids, including:
- Acids: sulfuric acid, hydrochloric acid, nitric acid, hydrofluoric acid, phosphoric acid
- Alkalis: caustic soda, soda ash
- Salt solutions
- Chemical solvents
Material selection should be confirmed according to medium composition, concentration and temperature.
Pharmaceutical Industry
Used for transferring corrosive liquids in the production of pharmaceutical intermediates and chemical APIs.
Environmental Protection and Water Treatment
Suitable for:
- Acid and alkali wastewater neutralization
- Transfer of ion exchange regeneration liquid
Coating Industry
Used for:
- Circulation of pretreatment tank liquids
- Circulation of electrophoretic paint
Laboratory Applications
Applicable for transfer and circulation of corrosive chemical reagents in laboratory processes.
Technical Specifications
Design Standard
The acid and alkali resistant self-priming pump is designed and manufactured with reference to relevant industry standards and enterprise standards.
The wetted part materials, hydraulic model and installation dimensions can be customized according to customer requirements.
Structure and Working Principle
The pump is a vertical, single-stage, single-suction, sealless self-priming centrifugal pump.
The motor is installed on the motor seat above the pump body. The pump body can be placed directly on the tank or installed on an external working platform beside the tank.
Inside the enlarged pump head, there is a large-capacity liquid storage chamber and a labyrinth-type gas-liquid separation chamber, forming an external-mixing self-priming system.
Working Principle
Before the first startup, the pump body must be filled with liquid.
After startup, the impeller rotates at high speed and mixes the liquid stored in the liquid chamber with the air in the suction pipeline. Under centrifugal force, the gas-liquid mixture enters the gas-liquid separation chamber.
As the flow velocity suddenly decreases in the separation chamber, the lighter gas is separated and discharged. The degassed liquid then flows back to the liquid storage chamber and participates in the circulation again.
This process repeats continuously, reducing the air in the suction pipeline until all air is exhausted and the self-priming process is completed. The pump then enters normal operation.
After shutdown, a certain volume of liquid remains in the storage chamber, so no additional priming is required for the next startup.
Wetted Parts Material Selection
|
Code / Material |
Description |
Typical Applications |
Temperature Range |
|
FN / FRPP |
Reinforced polypropylene |
General acid and alkali liquids, electroplating solutions |
-20℃ to 80℃ |
|
FP / PVDF |
Polyvinylidene fluoride |
Strong acids and alkalis, hydrofluoric acid, chemical solvents |
-20℃ to 120℃ |
|
FZ / PFA |
Melt-processable PTFE |
Strong acids, aqua regia, strong oxidizing agents |
-20℃ to 150℃ |
|
FT / Ti |
Titanium alloy |
Strong oxidizing acids, high-temperature concentrated acids |
≤100℃ |
|
FS / SUS304 |
304 stainless steel |
General acid and alkali liquids |
≤80℃ |
|
FS / SUS316 |
316 / 316L stainless steel |
Chloride-containing media, moderately corrosive liquids |
≤80℃ |
Transmission and Rotation Direction
The motor is directly connected to the pump shaft through a flexible coupling.
Viewed from the motor end toward the pump, the pump rotates clockwise.
Reverse rotation is not allowed.
Operating Conditions
|
Item |
Parameter |
|
Flow rate Q |
2–800 m³/h, covering the full series |
|
Head H |
5–35 m, single-stage head |
|
Speed n |
2900 / 1450 r/min, depending on model |
|
Medium temperature |
-20℃ to 150℃, depending on wetted material |
|
Self-priming height |
≤ 4–5 m, subject to medium density |
|
Diameter range |
25–150 mm, inlet / outlet |
|
Motor power |
0.75–30 kW, calculated according to operating conditions |
Operating Precautions
Before the first startup, the pump body must be filled with the liquid to be pumped. Long-time dry running is strictly prohibited. For subsequent startups, no additional priming is required.
Viewed from the motor end toward the pump, the pump rotates clockwise. Reverse operation is not allowed.
During installation, hydraulic losses in the suction pipeline should be minimized. The number of 90° elbows in the inlet pipeline should not exceed two.
The bolts of the suction pipe connection must be tightened evenly, and the sealing must be reliable. Air leakage is strictly not allowed; otherwise, the self-priming performance will be seriously affected.
If the pump fails to discharge liquid for a long time within the specified self-priming height range, stop the pump immediately and check the cause, especially whether there is air leakage in the inlet pipe. This prevents the working liquid inside the pump from overheating and damaging the pump.
When transferring special corrosive media, the medium name, temperature, concentration, density and other information must be specified when ordering, so that the manufacturer can select suitable materials and configurations.
Plastic material pumps such as PVDF and FRPP pumps should be protected from long-term direct sunlight and should avoid operation under extremely low-temperature conditions.
If the pump is not used for a long time in winter, the liquid inside the pump body should be drained completely to prevent freezing and cracking of the pump body.
Structural Drawings

Performance Data Tables
|
Model |
Flow Rate (m³/h) |
Head (m) |
Power (kW) |
Voltage (V) |
Speed (r/min) |
Inlet / Outlet Diameter (mm) |
Self-Priming Height (m) |
Self-Priming Time (min) |
|
25FN-16 |
2.5 |
18 |
0.75 |
220/380 |
2860 |
25×20 |
3 |
2 |
|
25FN-22 |
2.5 |
22 |
1.1 |
220/380 |
2860 |
25×20 |
3 |
2 |
|
25FN-26 |
2.5 |
26 |
1.5 |
220/380 |
2860 |
25×20 |
3 |
2 |
|
25FN-32 |
2.5 |
32 |
2.2 |
220/380 |
2860 |
25×20 |
3 |
2 |
|
32FN-18 |
3.2 |
18 |
1.1 |
220/380 |
2860 |
32×25 |
3 |
2 |
|
32FN-22 |
3.2 |
22 |
1.5 |
220/380 |
2860 |
32×25 |
3 |
2 |
|
32FN-26 |
3.2 |
26 |
2.2 |
220/380 |
2860 |
32×25 |
3 |
2 |
|
32FN-32 |
3.2 |
32 |
3 |
380 |
2860 |
32×25 |
3 |
2 |
|
40FN-18 |
6.3 |
18 |
1.5 |
220/380 |
2860 |
40×32 |
3 |
2 |
|
40FN-22 |
6.3 |
22 |
2.2 |
220/380 |
2860 |
40×32 |
3 |
2 |
|
40FN-26 |
6.3 |
26 |
3 |
380 |
2860 |
40×32 |
3 |
2 |
|
40FN-32 |
6.3 |
32 |
4 |
380 |
2860 |
40×32 |
3 |
2 |
|
40FN-40 |
6.3 |
40 |
5.5 |
380 |
2860 |
40×32 |
3 |
2 |
|
50FN-18 |
12.5 |
18 |
2.2 |
220/380 |
2860 |
50×40 |
3 |
2 |
|
50FN-22 |
12.5 |
22 |
3 |
380 |
2860 |
50×40 |
3 |
2 |
|
50FN-26 |
12.5 |
26 |
4 |
380 |
2860 |
50×40 |
3 |
2 |
|
50FN-32 |
12.5 |
32 |
5.5 |
380 |
2860 |
50×40 |
3 |
2 |
|
65FN-18 |
25 |
18 |
4 |
380 |
2860 |
65×50 |
3 |
2 |
|
65FN-22 |
25 |
22 |
5.5 |
380 |
2860 |
65×50 |
3 |
2 |
|
65FN-26 |
25 |
26 |
7.5 |
380 |
2860 |
65×50 |
3 |
2 |
|
80FN-18 |
50 |
18 |
5.5 |
380 |
2860 |
80×65 |
3 |
2 |
|
80FN-22 |
50 |
22 |
7.5 |
380 |
2860 |
80×65 |
3 |
2 |
|
100FN-18 |
100 |
18 |
11 |
380 |
2860 |
100×80 |
3 |
2 |
If you cannot find the required specifications or model in our product range, please contact us at any time. Our technical specialists will provide prompt model selection assistance and a customized technical solution.
Hot Tags: acid and alkali resistant self-priming pump “big head” self-priming pump, China acid and alkali resistant self-priming pump “big head” self-priming pump manufacturers, factory