Product Overview
A rotary vane vacuum pump is a positive-displacement mechanical vacuum pump. It generates vacuum through the rotation of an eccentric rotor fitted with vanes that slide in slots in the rotor. When a working fluid-typically special vacuum oil-is used to lubricate the pump and fill clearances in the pumping chamber, the pump is called an oil-sealed rotary vane vacuum pump. Without a working fluid, it is a dry rotary vane vacuum pump.
The main components include the pump body (stator), rotor, vanes, end covers, springs and exhaust valve. The rotor is mounted eccentrically inside a cylindrical pumping chamber. Its outer surface runs with a small clearance from the chamber wall. Two or more vanes are fitted into slots in the rotor. As the rotor turns, centrifugal force and spring tension keep the vane tips in contact with the chamber wall, dividing the chamber into working spaces of varying volume.
Rotary vane pumps are available in single-stage and two-stage configurations. A two-stage pump connects two pumping stages in series, typically a low-vacuum stage and a high-vacuum stage. Gas is compressed and discharged in sequence to achieve a higher vacuum. The stated ultimate pressure for a two-stage pump is approximately 6 × 10⁻² to 1 × 10⁻² Pa. A single-stage pump typically reaches an ultimate pressure of around 4 Pa or 50–200 Pa, depending on its design and operating parameters.
In common Chinese usage, belt-driven models are generally called rotary vane vacuum pumps, while models directly coupled to a motor or connected by a coupling are called direct-drive rotary vane vacuum pumps. Common product series include:
- 2X series: belt-driven, two-stage rotary vane pumps
- 2XZ series: direct-drive, two-stage rotary vane pumps
- XD series: direct-drive, single-stage rotary vane pumps
- WX series: oil-free rotary vane pumps
Model designation example: 2XZ-4B
- 2: Two-stage pump
- X: Rotary vane type
- Z: Direct-drive type; without "Z," the pump is belt-driven
- 4: Nominal pumping speed of 4 L/s
- B: Design revision or version code
Product Features
1. Direct start from atmospheric pressure
The pump can start at atmospheric pressure and discharge directly to atmosphere, without an auxiliary backing pump. It can operate continuously with atmospheric pressure at the inlet, making startup and operation straightforward.
2. Good pumping-speed characteristics
The pump can maintain useful pumping speed at low inlet pressures. According to the stated standard requirements, at inlet pressures of 1,333 Pa, 1.33 Pa and 1.33 × 10⁻¹ Pa, the pumping speed must be at least 95%, 50% and 20%, respectively, of the nominal pumping speed.
3. High vacuum with a two-stage design
A two-stage pump connects two single-stage pumping sections in series. Gas discharged from the first stage enters the second stage for further compression and discharge. Oil in the second stage is degassed to help prevent gas dissolved in the oil from being released back toward the vacuum side. The stated ultimate pressure is 6 × 10⁻² Pa or lower, significantly below that of a single-stage pump.
4. Gas ballast for condensable vapors
A rotary vane pump can be fitted with a gas ballast. During compression, the ballast admits a controlled quantity of dry air into the pump chamber. This lowers the partial pressure of water vapor and other condensable gases, helping prevent them from condensing and contaminating the pump oil.
A gas-ballast-equipped pump can handle a limited quantity of condensable vapor, making it more suitable for damp applications.
5. Smooth operation and low noise
Precision machining and dynamic balancing help reduce rotor imbalance, vibration and noise. The stated noise range is typically 48–75 dB(A); some miniature pumps may operate below 50 dB(A).
6. Built-in protection against oil backflow
Rotary vane pumps are generally fitted with an automatic anti-suckback valve. When the pump stops, the valve closes the inlet passage to help prevent oil from flowing back into the vacuum vessel or piping due to the pressure difference between the vacuum and atmospheric sides.
7. Compact construction
The pump has a compact footprint and can be integrated into a range of vacuum systems, helping save installation space.
8. Straightforward maintenance
Air-cooled models do not require cooling-water connections. Routine maintenance generally includes checking the oil level, changing the vacuum-pump oil and cleaning the filters. Wear parts such as vanes and seals can be replaced.
Accessories-including oil-mist filters, dust filters, odor filters and temperature-controlled water-regulating valves-can be supplied to suit different applications.
Applications
Rotary vane vacuum pumps are used across a wide range of industries and pumping-speed requirements. Typical applications include:
- Electronics and electric-light-source manufacturing: Evacuation of electron tubes, cathode-ray tubes, light bulbs, fluorescent lamps and vacuum-flask liners; vacuum generation for semiconductor devices and vacuum-electronic component packaging.
- Vacuum metallurgy and heat treatment: Vacuum melting, brazing, impregnation, heat treatment and casting.
- Coating and surface treatment: Evacuation for vacuum coating, vacuum holding, thermoforming and vacuum forming.
- Drying and freezing: Vacuum drying, concentration and freeze-drying.
- Packaging: Vacuum and modified-atmosphere packaging for food and pharmaceuticals, and vacuum pick-and-place or material feeding on automatic packaging lines.
- Pharmaceuticals and research: Vacuum operations in pharmaceutical-intermediate production; laboratory instruments such as centrifugal evaporators, mass spectrometers and electron microscopes; and backing service for diffusion and turbomolecular pumps.
- Automotive and refrigeration: Automotive air-conditioning service, evacuation of refrigerator and air-conditioning compressors, and vacuum processing in refrigeration-equipment production.
- Chemical and petroleum industries: Vacuum distillation, filtration, degassing and use in oil-purification equipment.
- Paper and printing: Vacuum sheet feeding in printing machinery, vacuum systems for plate-making equipment and vacuum dewatering in papermaking.
- Environmental protection: Vacuum treatment of industrial wastewater and support for equipment used in exhaust-gas sampling and environmental monitoring.
Technical Specifications
1. Design Standards
Rotary vane vacuum pumps are stated to comply with the following Chinese mechanical-industry standards:
JB/T 6533-2017, Rotary Vane Vacuum Pumps
JB/T 8944-2019, Single-Stage Rotary Vane Vacuum Pumps - applicable to single-stage models
The cited standards cover terminology, types and basic parameters, technical requirements, sampling and acceptance, inspection conditions and items, inspection rules, marking, packaging, transport and storage.
2. Operating Principle
A rotary vane pump is a rotary positive-displacement vacuum pump. A slotted rotor is mounted eccentrically inside a cylindrical pump casing (stator). As the rotor turns at high speed, centrifugal force and spring force push the vanes outward so that they slide against the inner wall of the casing.
The vanes divide the crescent-shaped space inside the pump into three functional zones:
- Intake zone: The volume increases, creating suction and drawing gas into the pump.
- Compression zone: The volume decreases and compresses the gas.
- Exhaust zone: When the gas pressure exceeds the exhaust-valve opening pressure, it opens the valve and is discharged.
In a two-stage pump, the first-stage section compresses the incoming gas to an intermediate pressure. The second-stage section compresses it further before discharge, enabling a lower ultimate pressure.
In an oil-sealed pump, the exhaust valve is immersed in oil. The oil helps seal the pump, absorb heat from compression and lubricate moving parts. An oil film between the rotor and casing fills clearances and small dead spaces, reducing internal leakage and improving the compression ratio.
3. Pump Types
Rotary vane vacuum pumps can be classified in several ways.
By pressure range
Single-stage: One pumping chamber. The stated ultimate pressure is around 4 Pa for some small direct-drive models, or around 50–200 Pa for some larger belt-driven models. Used for rough or general low-vacuum service.
Two-stage: Two pumping chambers connected in series. The stated ultimate pressure is approximately 6 × 10⁻² to 1 × 10⁻² Pa. Used where a higher vacuum is required.
By working-fluid arrangement
- Oil-sealed (oil-lubricated): Vacuum pump oil provides sealing, lubrication and cooling. This is the most common rotary vane pump configuration.
- Dry (oil-free): Operates without a working fluid and is intended for applications sensitive to oil contamination.
By drive arrangement
- Belt-driven: The motor drives the pump shaft through a V-belt. Typical speeds are 300–600 r/min. This arrangement generally operates at a lower speed and can be convenient to service.
- Direct-drive: The motor shaft is directly connected to the pump shaft, or connected through a flexible coupling. Typical speeds are 1,400–3,000 r/min. Direct-drive models are compact and are common in smaller pump applications.
4. Operating Conditions and General Range
- Pumping speed:
- Two-stage 2X series: 0.5–70 L/s
- Single-stage EM series: 4–51 m³/h
- Large single-stage industrial pumps: 16–840 m³/h
- Ultimate pressure, two-stage, gas ballast closed: ≤6 × 10⁻² Pa
- Ultimate pressure, single-stage, gas ballast closed: ≤2 mbar (266 Pa)
- Operating pressure range: 101,325 Pa to 1.33 × 10⁻² Pa
- Rotational speed: 300–3,000 r/min
- Belt-driven: typically 300–600 r/min
- Direct-drive: typically 1,400–3,000 r/min
- Motor power: 0.25–18.5 kW
- Cooling: Natural or forced-air cooling for small pumps; water cooling is typically used for larger pumps with pumping speeds of 30 L/s or more
- Service temperature: For normal ambient-temperature operation. The source specifies a pump-temperature limit of 40°C; confirm whether this refers to the pump's temperature rise or another temperature limit.
5. Operating Precautions
- Do not use the pump for gases with excessively high oxygen content, gases corrosive to metals, gases that react chemically with the pump oil, or gas streams containing dust and particles.
- Before initial startup, check that the oil level is within the specified range. After starting the pump, open the inlet valve gradually.
- When pumping condensable vapors, open the gas-ballast valve and allow the pump to warm up fully before closing it.
- Check that the pump operates normally, with no unusual noise or motor overload.
- If the ambient temperature may fall below 5°C after shutdown, drain the cooling water from the pump to prevent freezing damage.
- For hazardous, toxic or corrosive gases, install suitable neutralizing, cooling or filtration equipment in the inlet line.
6. General Performance Range
- Pumping speed: 0.5–70 L/s for two-stage models; 4–840 m³/h for single-stage models
- Ultimate pressure, two-stage, gas ballast closed: ≤6 × 10⁻² Pa
- Ultimate pressure, single-stage, gas ballast closed: ≤2 mbar (266 Pa)
- Operating pressure range: 101,325 Pa to 1.33 × 10⁻² Pa
- Rotational speed: 300–3,000 r/min, depending on drive arrangement
- Motor power: 0.25–18.5 kW
- Noise level: 48–75 dB(A), depending on pump size
- Cooling: Air cooling for smaller pumps; water cooling for larger pumps, typically at pumping speeds of 30 L/s or more
- Temperature limit: ≤40°C, as stated in the source; clarify the meaning with the manufacturer
- Suitable gases: Dry air and limited quantities of condensable vapors when the gas ballast is open. Not suitable for gases with excessive oxygen content, corrosive gases or dust-laden gas streams.
Structural Drawings

Performance Data Tables
|
Model |
Test flow rate |
Test head |
Speed |
Efficiency |
Motor power |
NPSHr |
|
(m³/h) |
(m) |
(r/min) |
(%) |
(kW) |
(m) |
|
|
xpb32-20-125 |
2.56 |
12 |
2900 |
35 |
Selected based on specific gravity and viscosity |
5 |
|
xpb32-20-125A |
2.4 |
9.6 |
2900 |
32 |
Selected based on specific gravity and viscosity |
5 |
|
xpb32-20-125 |
1.28 |
3 |
1450 |
32 |
Selected based on specific gravity and viscosity |
4 |
|
xpb32-20-160 |
2.56 |
19.2 |
2900 |
30 |
Selected based on specific gravity and viscosity |
3.5 |
|
xpb32-20-160A |
2.4 |
15.6 |
2900 |
28 |
Selected based on specific gravity and viscosity |
3.5 |
|
xpb32-20-160 |
1.28 |
4.8 |
1450 |
25 |
Selected based on specific gravity and viscosity |
3.5 |
|
xpb32-20-200 |
2.56 |
30 |
2900 |
27 |
Selected based on specific gravity and viscosity |
4 |
|
xpb32-20-200A |
2.4 |
24 |
2900 |
25 |
Selected based on specific gravity and viscosity |
4 |
|
xpb32-20-200 |
1.28 |
7.5 |
1450 |
20 |
Selected based on specific gravity and viscosity |
3.5 |
|
xpb32-20-250 |
2.56 |
48 |
2900 |
17 |
Selected based on specific gravity and viscosity |
4.5 |
|
xpb32-20-250A |
2.4 |
39 |
2900 |
16 |
Selected based on specific gravity and viscosity |
4.5 |
|
xpb32-20-250 |
1.28 |
12 |
1450 |
16 |
Selected based on specific gravity and viscosity |
4.5 |
|
xpb40-25-125 |
5.04 |
12 |
2900 |
52 |
1.1 |
5 |
|
xpb40-25-125A |
4.16 |
9 |
2900 |
48 |
0.75 |
5 |
|
xpb40-25-125 |
2.52 |
3 |
1450 |
48 |
0.55 |
4 |
|
xpb40-25-160 |
5.04 |
19.2 |
2900 |
47 |
2.2 |
3.5 |
|
xpb40-25-160A |
4.16 |
15.6 |
2900 |
45 |
1.5 |
3.5 |
|
xpb40-25-160 |
2.52 |
4.8 |
1450 |
42 |
0.75 |
3.5 |
|
xpb40-25-200 |
5.04 |
30 |
2900 |
38 |
4 |
3.5 |
|
xpb40-25-200A |
4.16 |
24 |
2900 |
36 |
3 |
3.5 |
|
xpb40-25-250 |
2.52 |
7.5 |
1450 |
33 |
1.1 |
3.5 |
|
xpb40-25-250A |
5.04 |
48 |
2900 |
32 |
7.5 |
4.5 |
|
xpb40-25-250 |
4.16 |
39 |
2900 |
30 |
5.5 |
4.5 |
|
xpb40-25-250 |
2.52 |
12 |
1450 |
27 |
2.2 |
4.5 |
|
xpb50-32-125 |
10 |
12 |
2900 |
51 |
1.5 |
2 |
|
xpb50-32-125A |
9.04 |
9.72 |
2900 |
50 |
1.5 |
2 |
|
xpb50-32-125 |
5.04 |
3 |
1450 |
45 |
0.55 |
2 |
|
xpb50-32-160 |
10 |
19.2 |
2900 |
46 |
3 |
2.5 |
|
xpb50-32-160A |
8.96 |
15.6 |
2900 |
45 |
2.2 |
2.5 |
|
xpb50-32-160 |
5.04 |
4.8 |
1450 |
40 |
0.55 |
2.5 |
|
xpb50-32-200 |
10 |
30 |
2900 |
39 |
5.5 |
2.5 |
|
xpb50-32-200A |
9.04 |
24 |
2900 |
37 |
4 |
2.5 |
|
xpb50-32-250 |
5.04 |
7.5 |
1450 |
33 |
0.75 |
2.5 |
|
xpb50-32-250A |
10 |
48 |
2900 |
33 |
11 |
3 |
|
xpb50-32-250 |
8.96 |
39 |
2900 |
31 |
7.5 |
3 |
|
xpb50-32-250 |
5.04 |
12 |
1450 |
27 |
2.2 |
3 |
|
xpb65-50-125 |
20 |
12 |
2900 |
62 |
3 |
2.5 |
|
xpb65-50-125A |
18 |
9.6 |
2900 |
61 |
2.2 |
2.5 |
|
xpb65-50-125 |
10 |
3 |
1450 |
55 |
0.55 |
2.5 |
|
xpb65-50-160 |
20 |
19.2 |
2900 |
57 |
4 |
2.5 |
|
xpb65-50-160A |
18 |
15.6 |
2900 |
56 |
3 |
2.5 |
|
xpb65-50-160 |
10 |
4.8 |
1450 |
51 |
0.75 |
2.5 |
|
xpb65-40-200 |
20 |
30 |
2900 |
57 |
7.5 |
3 |
|
xpb65-40-200A |
18 |
24 |
2900 |
56 |
5.5 |
3 |
|
xpb65-40-200 |
10 |
7.5 |
1450 |
50 |
1.1 |
3 |
|
xpb65-40-250 |
20 |
48 |
2900 |
50 |
15 |
3 |
|
xpb65-40-250A |
18 |
39 |
2900 |
49 |
11 |
3 |
|
xpb65-40-250 |
10 |
12 |
1450 |
44 |
2.2 |
3 |
|
xpb80-65-125 |
40 |
12 |
2900 |
70 |
5.5 |
3 |
|
xpb80-65-125A |
36 |
9.6 |
2900 |
68 |
4 |
3 |
|
xpb80-65-125 |
20 |
3 |
1450 |
61 |
0.75 |
3 |
|
xpb80-65-160 |
40 |
19.2 |
2900 |
67 |
7.5 |
3 |
|
xpb80-65-160A |
36 |
15.6 |
2900 |
66 |
5.5 |
3 |
|
xpb80-65-160 |
20 |
4.8 |
1450 |
57 |
1.1 |
3 |
|
xpb80-50-200 |
40 |
30 |
2900 |
63 |
15 |
3 |
|
xpb80-50-200A |
36 |
24 |
2900 |
62 |
11 |
3 |
|
xpb80-50-200 |
20 |
7.5 |
1450 |
55 |
1.5 |
3 |
|
xpb80-50-250 |
40 |
48 |
2900 |
58 |
22 |
3.5 |
|
xpb80-50-250A |
36 |
39 |
2900 |
57 |
15 |
3.5 |
|
xpb80-50-250 |
20 |
12 |
1450 |
50 |
2.2 |
3.5 |
|
xpb100-80-125 |
80 |
12 |
2900 |
73 |
11 |
4 |
|
xpb100-80-125A |
72 |
9.6 |
2900 |
71 |
7.5 |
4 |
|
xpb100-80-125 |
40 |
3 |
1450 |
66 |
1.5 |
4 |
|
xpb100-80-160 |
80 |
19.2 |
2900 |
72 |
15 |
4 |
|
xpb100-80-160A |
72 |
15.6 |
2900 |
71 |
11 |
4 |
|
xpb100-80-160 |
40 |
4.8 |
1450 |
63 |
2.2 |
4 |
|
xpb100-65-200 |
80 |
30 |
2900 |
68 |
22 |
4 |
|
xpb100-65-200A |
72 |
24 |
2900 |
67 |
18.5 |
4 |
|
xpb100-65-200 |
40 |
7.5 |
1450 |
60 |
3 |
4 |
|
xpb100-65-250 |
80 |
48 |
2900 |
62 |
37 |
4.5 |
|
xpb100-65-250A |
72 |
39 |
2900 |
61 |
30 |
4.5 |
|
xpb100-65-250 |
40 |
12 |
1450 |
55 |
5.5 |
4.5 |
|
xpb125-100-200 |
160 |
30 |
2900 |
72 |
45 |
4.5 |
|
xpb125-100-200A |
144 |
24 |
2900 |
71 |
37 |
4.5 |
|
xpb125-100-200 |
80 |
7.5 |
1450 |
65 |
7.5 |
4.5 |
|
xpb125-100-250 |
160 |
48 |
2900 |
68 |
75 |
5 |
|
xpb125-100-250A |
144 |
39 |
2900 |
67 |
55 |
5 |
|
xpb125-100-250 |
80 |
12 |
1450 |
60 |
11 |
5 |
|
xpb150-125-250 |
240 |
48 |
2900 |
70 |
110 |
5.5 |
|
xpb150-125-250A |
216 |
39 |
2900 |
69 |
90 |
5.5 |
|
xpb150-125-250 |
120 |
12 |
1450 |
63 |
18.5 |
5.5 |
|
xpb150-125-315 |
240 |
75 |
2900 |
66 |
160 |
6 |
|
xpb150-125-315A |
216 |
60 |
2900 |
65 |
132 |
6 |
|
xpb150-125-315 |
120 |
19.2 |
1450 |
58 |
22 |
6 |
|
xpb200-150-315 |
320 |
75 |
2900 |
68 |
220 |
6.5 |
|
xpb200-150-315A |
288 |
60 |
2900 |
67 |
185 |
6.5 |
|
xpb200-150-315 |
160 |
19.2 |
1450 |
60 |
30 |
6.5 |
If you cannot find the required specifications or model in our product range, please contact us at any time. Our technical specialists will provide prompt model selection assistance and a customized technical solution.
Hot Tags: rotary vane vacuum pump, China rotary vane vacuum pump manufacturers, factory