Product Overview
The all-plastic magnetic drive pump, also known as an all-plastic magnetically driven pump, is a fully sealed, leak-free pumping device that applies the operating principle of a permanent-magnet coupling to centrifugal pumping.
The pump consists of three main sections:
- Pump casing
- Magnetic-drive assembly
- Electric motor
Magnetic-Drive Operating Principle
The magnetic-drive assembly consists of:
- External magnetic rotor
- Internal magnetic rotor
- Non-magnetic containment shell
During operation, the motor drives the external magnetic rotor. The magnetic field passes through the stationary containment shell and synchronously drives the internal magnetic rotor connected to the impeller.
This arrangement transmits power without physical contact and replaces the dynamic shaft seal used in conventional centrifugal pumps with a static sealing structure.
As a result, the pumped medium remains completely enclosed within the pump casing and containment shell, achieving theoretically zero leakage.
Product Features
All wetted components-including the pump casing, impeller, and internal magnetic assembly-are manufactured from engineering plastics.
Typical materials include:
- Reinforced polypropylene
- Fluoroplastic alloy F50-1
- F46 fluoroplastic
- Other application-specific corrosion-resistant plastics
These components are produced through integral injection molding or compression molding.
The all-plastic construction provides excellent resistance to corrosive media, particularly:
- Strong acids
- Strong alkalis
- Chloride-containing liquids
- Salts
- Other aggressive chemical solutions
It is especially suitable for operating conditions where conventional metallic materials cannot provide sufficient corrosion resistance.
Applications
1. Main Industries and Fields
The all-plastic magnetic drive pump is widely used in the following industries and applications:
- Petrochemical industry: Transfer of corrosive chemical media such as acids, alkalis, and salts
- Fine chemicals: Synthesis and transfer of dyes, pesticides, pharmaceutical intermediates, and related products
- Pharmaceutical industry: Transfer of pharmaceutical solutions, solvents, and other clean liquids
- Electroplating and surface treatment: Circulation and transfer of plating solutions, pickling liquids, and electroless-plating solutions
- Non-ferrous metal smelting: Transfer of electrolytes, pickling solutions, and other corrosive process liquids
- Rare-earth separation: Transfer of extractants, acid and alkaline solutions, and other process media
- Environmental water treatment: Wastewater treatment, acid–alkali neutralization, and chemical dosing systems
- Electronics and PCB manufacturing: Circulation of etching solutions, developing solutions, and other process chemicals
- Scientific research: Liquid transfer in small-scale laboratory chemical systems
2. Suitable Pumped Media
The pump is particularly suitable for transferring:
a. Strong acids, strong alkalis, and other corrosive liquids
b. Flammable and explosive liquids
c. Toxic and hazardous liquids
d. Rare, valuable, or high-cost liquids
e. High-purity liquids
f. Volatile liquids
The actual wetted material must be selected according to the medium's chemical composition, concentration, temperature, and operating pressure.
Technical Specificationsption
1. Operating Principle
The all-plastic magnetic drive pump transfers power through a magnetic coupling.
The motor drives the external magnetic rotor, generating a strong magnetic field that passes through the stationary non-magnetic containment shell. This magnetic field drives the internal magnetic rotor and the impeller connected to it to rotate synchronously.
Because the impeller and internal magnetic rotor are integrated into one rotating assembly, the pumped liquid remains enclosed within the pump chamber and containment shell. Mechanical power is transmitted to the impeller without physical contact.
This design converts the dynamic seal used around a conventional pump shaft into a static seal at the containment shell. The result is a fully enclosed and leak-free pumping system.
2. General Performance Range
|
Parameter |
Specification |
|
Flow rate |
0.6–100 m³/h |
|
Head |
2–50 m |
|
Standard speed |
2,900 r/min |
|
Motor power |
0.01–18.5 kW |
|
General operating temperature range |
−40°C to +100°C |
|
Design pressure |
0.6–1.6 MPa |
|
Pump casing materials |
Reinforced polypropylene, fluoroplastic alloy F50, F46 |
|
Applicable media |
Acids, alkalis, salts, and other corrosive media across a broad concentration range |
3. Operating Conditions
The following operating conditions should be observed during pump selection and operation.
Medium Density
For the standard configuration, the pumped-medium density should generally not exceed:
1,300 kg/m³
Higher-density media may require motor-power verification and a special pump configuration.
Medium Viscosity
The stated viscosity limit is:
≤ 30 × 10⁻⁶ m²/s
This is equivalent to approximately 30 cSt when expressed as kinematic viscosity. The manufacturer's original unit should be confirmed before final technical publication.
Medium Composition
The pumped medium must not contain:
- Ferromagnetic substances
- Fibrous materials
- Large or hard solid particles
These materials may damage the magnetic-drive assembly, bearings, impeller, or containment shell.
Temperature and Pressure Limitation
For the all-plastic pump casing:
The operating temperature is generally limited to ≤ 60°C.
The corresponding rated pressure is 0.6 MPa.
Although the general technical range states a maximum temperature of up to 100°C, the actual allowable value must be determined by the specific plastic material, pressure, medium, and pump model.
Dry-Running Protection
Dry running is strictly prohibited.
The sliding bearings are lubricated and cooled by the pumped medium. If the pump operates without sufficient liquid:
- Bearing temperature may rise rapidly.
- Sliding surfaces may seize or wear severely.
- The internal magnetic rotor may be damaged.
- The containment shell may overheat.
- Permanent pump failure may occur.
The pump should therefore be completely filled with liquid before starting, and appropriate dry-running or liquid-level protection should be installed where necessary.
Structural Drawings

Performance Data Tables
|
Model |
Flow Rate (m³/h) |
Head (m) |
Speed (r/min) |
Motor Power (kW) |
Inlet Diameter (mm) |
Outlet Diameter (mm) |
Efficiency (%) |
Required NPSH (m) |
Allowable Medium Temperature (°C) |
|
CQF10-8-50 |
0.5 |
8 |
2900 |
0.025 |
10 |
8 |
12 |
2 |
-20~100 |
|
CQF15-10-80 |
1.5 |
10 |
2900 |
0.12 |
15 |
10 |
18 |
2.5 |
-20~100 |
|
CQF20-15-105 |
3.2 |
12.5 |
2900 |
0.37 |
20 |
15 |
28 |
3 |
-20~100 |
|
CQF25-20-125 |
3.6 |
20 |
2900 |
0.75 |
25 |
20 |
32 |
3 |
-20~100 |
|
CQF32-25-125 |
5 |
20 |
2900 |
1.1 |
32 |
25 |
38 |
3 |
-20~100 |
|
CQF32-25-160 |
6.3 |
32 |
2900 |
2.2 |
32 |
25 |
35 |
3.5 |
-20~100 |
|
CQF40-32-125 |
12.5 |
20 |
2900 |
2.2 |
40 |
32 |
48 |
3.5 |
-20~100 |
|
CQF40-32-160 |
12.5 |
32 |
2900 |
3 |
40 |
32 |
45 |
3.5 |
-20~100 |
|
CQF40-32-200 |
12.5 |
50 |
2900 |
5.5 |
40 |
32 |
40 |
4 |
-20~100 |
|
CQF50-32-125 |
12.5 |
20 |
2900 |
3 |
50 |
32 |
50 |
3.5 |
-20~100 |
|
CQF50-32-160 |
12.5 |
32 |
2900 |
4 |
50 |
32 |
48 |
3.5 |
-20~100 |
|
CQF50-32-200 |
12.5 |
50 |
2900 |
7.5 |
50 |
32 |
45 |
4 |
-20~100 |
|
CQF50-32-250 |
12.5 |
80 |
2900 |
15 |
50 |
32 |
38 |
4.5 |
-20~100 |
|
CQF65-50-125 |
25 |
20 |
2900 |
4 |
65 |
50 |
58 |
3.5 |
-20~100 |
|
CQF65-50-160 |
25 |
32 |
2900 |
7.5 |
65 |
50 |
55 |
3.5 |
-20~100 |
|
CQF65-40-200 |
25 |
50 |
2900 |
11 |
65 |
40 |
50 |
4 |
-20~100 |
|
CQF65-40-250 |
25 |
80 |
2900 |
18.5 |
65 |
40 |
45 |
4.5 |
-20~100 |
|
CQF80-65-125 |
50 |
20 |
2900 |
7.5 |
80 |
65 |
65 |
4 |
-20~100 |
|
CQF80-65-160 |
50 |
32 |
2900 |
11 |
80 |
65 |
63 |
4 |
-20~100 |
|
CQF80-50-200 |
50 |
50 |
2900 |
18.5 |
80 |
50 |
60 |
4.5 |
-20~100 |
|
CQF80-50-250 |
50 |
80 |
2900 |
30 |
80 |
50 |
55 |
5 |
-20~100 |
|
CQF100-80-125 |
100 |
20 |
2900 |
15 |
100 |
80 |
70 |
4.5 |
-20~100 |
|
CQF100-80-160 |
100 |
32 |
2900 |
22 |
100 |
80 |
68 |
4.5 |
-20~100 |
|
CQF100-65-200 |
100 |
50 |
2900 |
30 |
100 |
65 |
65 |
5 |
-20~100 |
|
CQF125-100-160 |
160 |
32 |
2900 |
30 |
125 |
100 |
72 |
5 |
-20~100 |
|
CQF125-100-200 |
160 |
50 |
2900 |
37 |
125 |
100 |
70 |
5.5 |
-20~100 |
|
CQF150-125-200 |
200 |
50 |
2900 |
55 |
150 |
125 |
72 |
5.5 |
-20~100 |
If you cannot find the required specifications or model in our product range, please contact us at any time. Our technical specialists will provide prompt model selection assistance and a customized technical solution.
Hot Tags: all-plastic magnetic drive pump, China all-plastic magnetic drive pump manufacturers, factory