Product Overview
The JHD Sanitary Single-Screw Pump is an internally meshing rotary positive-displacement pump. Its main components include the rotor, stator, universal joint, drive shaft, pump casing, and motor.
The rotor is a single-start stainless-steel helical rotor, while the stator is a sleeve with a double-start helical cavity lined with food-grade elastomer. As the rotor performs planetary motion around the stator axis, a series of continuous sealed cavities is formed between the rotor and stator. The conveyed medium is then displaced axially through these cavities at a uniform speed, enabling smooth, pulsation-free, and low-shear continuous conveying.
Designed specifically for sanitary applications, all wetted components are manufactured from SUS304 or SUS316L stainless steel and subjected to mirror polishing, with a surface roughness of Ra ≤ 0.8 μm. The internal flow passages are designed without dead zones to minimize material retention and residue.
The stator is available in food-grade materials such as NBR, EPDM, silicone rubber, and fluoroelastomer. The selected elastomer can be configured to meet applicable FDA sanitary requirements.
The pump casing has an optimized sanitary design and supports CIP (Clean-in-Place) and SIP (Sterilization-in-Place) operations. The sterilization temperature can reach 121°C or higher, enabling the pump to meet the hygienic and cleanliness requirements of food, pharmaceutical, and biopharmaceutical production.
Model Designation
Example: JHD-25-1
JHD: Series designation for the sanitary single-screw pump
25: Rated capacity, 25 L/min
1: Number of pump stages; single-stage configuration
Thus, JHD-25-1 represents a JHD sanitary single-screw pump with a rated capacity of 25 L/min and a single-stage design.
Product Features
Compliance with Sanitary Design Standards
All wetted components are manufactured from SUS304 or SUS316L stainless steel. The internal and external surfaces are mirror-polished to a surface roughness of Ra ≤ 0.8 μm.
The smooth flow passages are free of dead zones, minimizing material retention and preventing bacterial growth. The pump is designed to comply with GMP, 3-A Sanitary Standards, and EHEDG hygienic design requirements. Material certificates can be provided upon request.
CIP and SIP Capability
The pump casing is designed with smooth, unobstructed flow passages and no dead zones. CIP (Clean-in-Place) cleaning and SIP (Sterilization-in-Place) sterilization can be performed without dismantling the pump.
The sterilization temperature can reach 121°C or higher, satisfying the hygienic and cleanliness requirements of food and pharmaceutical production.
Smooth, Pulsation-Free Conveying with Minimal Shear
The medium is displaced axially at a uniform speed during pumping. The pump produces no significant vortexing or agitation, resulting in stable flow and extremely low pressure pulsation.
This characteristic is particularly beneficial for shear-sensitive media, such as:
- Fermentation broths
- Protein solutions
- Fruit-pulp slurries containing particles
The gentle conveying action helps preserve the structure and properties of the medium.
Excellent Self-Priming Capability and High Suction Lift
The pump provides strong self-priming capability, with a self-priming height of up to 8.5 m.
A foot valve is not required for start-up, making the pump suitable for low-liquid-level applications and suction from the bottom of tanks or vessels.
Suitable for High-Viscosity and Particle-Laden Media
The pump can convey high-viscosity liquids with viscosities of up to 200,000 cP, as well as slurries containing solid particles or fibrous materials.
The maximum particle size can reach the rotor eccentricity, provided that the particles do not exceed this limit. The solids content can generally reach approximately 40% by volume.
Food-Grade Stator Materials
The stator lining can be manufactured from food-grade materials, including:
- NBR - Nitrile rubber
- EPDM - Ethylene propylene diene monomer rubber
- Silicone rubber
- Fluoroelastomer
These materials are available to meet applicable FDA sanitary requirements and accommodate different media characteristics and operating temperatures.
Flow Rate Proportional to Speed for Easy Adjustment
The flow rate has a linear proportional relationship with the pump speed. The motor speed can be adjusted through a variable-frequency drive, enabling precise, stepless flow control.
With suitable configuration, the pump can also be used as a metering pump.
Modular Design for Easy Maintenance
The pump features a compact structure and a limited number of components. The rotor and stator are the primary wear parts, and their simple construction facilitates disassembly, replacement, and maintenance.
Different operating conditions can be accommodated simply by replacing the rotor and stator. This modular design also improves spare-parts interchangeability and simplifies inventory management.
Applications
The JHD Sanitary Single-Screw Pump is widely used for conveying liquids and slurries in applications with strict hygiene and cleanliness requirements.
• Food industry: Conveying milk, yogurt, cream, ice-cream mix, fruit juice, jam, honey, syrup, chocolate, edible oils, soy sauce, and other liquid food products.
• Beverage industry: Conveying beer, wine, distilled spirits, beverage concentrates, fruit-juice concentrates, tea beverages, and other drinks.
• Dairy industry: Handling fresh milk, pasteurized milk, UHT milk, milk-powder slurries, condensed milk, whey, and other dairy products.
• Pharmaceutical industry: Conveying pharmaceutical solutions, traditional Chinese medicine extracts, oral liquids, syrups, ointments, vaccines, plasma, fermentation broths, and other process media used in pharmaceutical and biopharmaceutical production.
• Biotechnology: Handling fermentation broths, culture media, inoculum suspensions, buffer solutions, protein solutions, enzyme preparations, and other bioprocess fluids.
• Cosmetics and Personal-Care Industry: Conveying high-viscosity liquids and particle-containing slurries in processes with demanding sanitary requirements.
• Fine Chemical Industry: Conveying high-viscosity liquids and particle-containing slurries in processes with demanding sanitary requirements.
The pump is especially suitable for products that are viscous, shear-sensitive, particle-laden, or prone to quality degradation under turbulent conveying conditions. Its sanitary construction, smooth flow passages, and CIP/SIP capability make it suitable for hygienically controlled production environments.
Technical Specifications
Design Standards
The pump is manufactured in accordance with sanitary design standards such as GMP, 3-A, and EHEDG, meeting the hygienic and cleanliness requirements of the food, pharmaceutical, and bioprocessing industries.
The technical conditions for the single-screw pump refer to:
GB/T 10885 - Technical Conditions for Single-Screw Pumps
ISO 15136
Applicable sanitary design and manufacturing requirements
Operating Principle
The JHD Sanitary Single-Screw Pump is an internally meshing rotary positive-displacement pump. Its main working components consist of a stator with a double-start helical cavity and a matching single-start helical rotor.
As the rotor performs planetary motion within the stator cavity, continuous sealed cavities are formed between the rotor and stator. These cavities move axially along the rotor, conveying the liquid uniformly, continuously, and at a constant rate from the suction inlet to the discharge outlet.
Construction
The pump is a horizontal single-screw pump. Its main components include:
- Rotor
- Stator
- Universal joint and drive shaft
- Pump casing
- Shaft seal
- Motor
The rotor is made of SUS304 or SUS316L stainless steel and has a mirror-polished surface.
The stator is lined with food-grade NBR, EPDM, silicone rubber, or fluoroelastomer, in compliance with applicable FDA sanitary requirements.
Stator Elastomer Selection
The stator material can be selected according to the characteristics of the medium and the operating temperature.
|
Stator Material |
Recommended Applications |
Maximum Temperature |
|
Food-grade NBR |
Fats, edible oils, and oil-containing food products |
≤120°C |
|
EPDM |
Hot water, beverages, mildly acidic or alkaline media, and CIP cleaning solutions |
≤150°C |
|
Silicone rubber |
Food, pharmaceutical, and bioprocessing products |
≤120°C |
|
Fluoroelastomer (FKM) |
Solvents, organic compounds, and highly corrosive media |
≤200°C |
All listed elastomer materials are available in food-grade configurations that meet applicable FDA requirements.
Shaft-Sealing System
The shaft seal can be selected according to the characteristics of the medium and the required hygiene level.
Available configurations include:
- Single sanitary mechanical seal
- Double mechanical seal
The sealing materials meet applicable sanitary requirements. The sealing system is designed for convenient cleaning and sterilization.
Drive Arrangement
The motor is directly connected to the pump through an elastic coupling. A variable-frequency drive can also be used for speed control.
When viewed from the motor end toward the pump, the pump rotates in a clockwise direction.
Operating Conditions
The main operating parameters are as follows:
| Flow rate, Q | 1–150 m³/h, covering the complete series |
| Operating pressure | Approximately 0.6 MPa for single-stage pumps; ≤2.4 MPa for multistage pumps |
| Viscosity | ≤200,000 cP; higher-viscosity media can be conveyed at reduced speed |
| Medium temperature | −20°C to 200°C, depending on the stator material |
| Rotational speed, n | 100–960 r/min, depending on the model |
| Self-priming height | ≤8.5 m under wet-suction conditions |
| Permitted particle diameter | ≤30 mm and not greater than the rotor eccentricity |
| Solids content | ≤40% by volume; more than 60% may be possible for fine powders, depending on the medium |
| Motor power | 0.55–75 kW, calculated according to the actual operating conditions |
The actual flow rate, pressure, speed, elastomer selection, sealing configuration, and motor power should be determined according to the medium properties and the specific operating conditions.
Structural Drawings

Performance Data Tables
|
Model |
Flow Rate (m³/h) |
Pressure (MPa) |
Speed (r/min) |
Motor Power (kW) |
Inlet Diameter (mm) |
Outlet Diameter (mm) |
Maximum Permissible Viscosity (mPa·s) |
Operating Temperature (°C) |
|
JHD1-1 |
0.1~0.5 |
0.6 |
200~500 |
0.55 |
DN25 |
DN25 |
100000 |
-10~120 |
|
JHD1-2 |
0.1~0.5 |
1.2 |
200~500 |
0.75 |
DN25 |
DN25 |
100000 |
-10~120 |
|
JHD2-1 |
0.3~1.2 |
0.6 |
200~500 |
1.1 |
DN32 |
DN25 |
200000 |
-10~120 |
|
JHD2-2 |
0.3~1.2 |
1.2 |
200~500 |
1.5 |
DN32 |
DN25 |
200000 |
-10~120 |
|
JHD3-1 |
0.5~2.5 |
0.6 |
200~500 |
2.2 |
DN40 |
DN32 |
300000 |
-10~120 |
|
JHD3-2 |
0.5~2.5 |
1.2 |
200~500 |
3 |
DN40 |
DN32 |
300000 |
-10~120 |
|
JHD4-1 |
1.0~5.0 |
0.6 |
200~400 |
4 |
DN50 |
DN40 |
500000 |
-10~120 |
|
JHD4-2 |
1.0~5.0 |
1.2 |
200~400 |
5.5 |
DN50 |
DN40 |
500000 |
-10~120 |
|
JHD5-1 |
2.0~8.0 |
0.6 |
200~350 |
7.5 |
DN65 |
DN50 |
800000 |
-10~120 |
|
JHD5-2 |
2.0~8.0 |
1.2 |
200~350 |
11 |
DN65 |
DN50 |
800000 |
-10~120 |
|
JHD6-1 |
3.0~15 |
0.6 |
150~300 |
11 |
DN80 |
DN65 |
1000000 |
-10~120 |
|
JHD6-2 |
3.0~15 |
1.2 |
150~300 |
15 |
DN80 |
DN65 |
1000000 |
-10~120 |
|
JHD7-1 |
5.0~25 |
0.6 |
150~250 |
15 |
DN100 |
DN80 |
1500000 |
-10~120 |
|
JHD7-2 |
5.0~25 |
1.2 |
150~250 |
18.5 |
DN100 |
DN80 |
1500000 |
-10~120 |
|
JHD8-1 |
10~40 |
0.6 |
100~200 |
22 |
DN125 |
DN100 |
2000000 |
-10~120 |
|
JHD8-2 |
10~40 |
1.2 |
100~200 |
30 |
DN125 |
DN100 |
2000000 |
-10~120 |
|
JHD9-1 |
20~60 |
0.6 |
100~180 |
30 |
DN150 |
DN125 |
3000000 |
-10~120 |
If you cannot find the required specifications or model in our product range, please contact us at any time. Our technical specialists will provide prompt model selection assistance and a customized technical solution.