CQB-DG High temperature magnetic drive pump
Product Description
CQB-DG High temperature magnetic drive pump is a type of pump that uses a magnetic coupling to transfer the rotational energy from the motor to the impeller. This design eliminates the need for a traditional mechanical seal, which makes it ideal for applications where leakage can be a problem.
The pump can handle a wide range of temperatures, making it suitable for use in industrial processes that require high-temperature fluids. It can also handle corrosive and aggressive fluids, thanks to the use of materials such as stainless steel and ceramic.
There are several different types of CQB-DG High temperature magnetic drive pump available, each with its own unique features and specifications. These include:
Single-stage CQB-DG High temperature magnetic drive pump
This pump has a single impeller and can be used for simple pumping applications.
01
Multi-stage CQB-DG High temperature magnetic drive pump
This pump has multiple impellers, which allows it to generate higher pressures and flow rates than a single-stage pump.
02
Self-priming CQB-DG High temperature magnetic drive pump
This pump is designed to be able to prime itself and does not require external priming.
03
Vertical CQB-DG High temperature magnetic drive pump
This pump is designed to be installed vertically, making it ideal for applications where space is limited.
04
Horizontal CQB-DG High temperature magnetic drive pump
This pump is designed to be installed horizontally and is ideal for applications where a high flow rate is required.
05
In conclusion, the CQB-DG High temperature magnetic drive pump is an essential piece of equipment in many industrial processes. With its ability to handle high temperatures and corrosive fluids, and its range of different types, it is easy to see why it is so popular in a wide range of applications.
Advantage
Strong corrosion resistance, high mechanical strength, non-aging, non-toxic decomposition.
Compact structure, beautiful appearance, small size and low noise.
It can transport any concentration of acid, alkali, strong oxidant and other corrosion media.
|
型 号Model |
流量(Flow) m3 /h |
扬程(Head) m |
汽蚀余量 NPSH m |
转速 Speed r/min |
轴功率(Power) Kw |
效率Rated Efficiency % |
配带电动机功率Kw(Motor power) |
|||||||||||||||||
|
介质密度(medium density)g/cm3 |
||||||||||||||||||||||||
|
≤1 |
≤1.3 |
≤1.84 |
||||||||||||||||||||||
|
CQB-DG 32-20-125 |
1.9 3.2 3.8 |
22 20 18.5 |
2900 |
0.49 0.58 0.62 |
23 30 31 |
|
|
|
||||||||||||||||
|
CQB-DG 32-20-160 |
1.9 3.2 3.8 |
34 32 29 |
2900 |
0.84 0.99 1.03 |
21 28 29 |
|
|
|
||||||||||||||||
|
CQB-DG 40-20-105 |
3.8 6.3 7.5 |
13 12.5 11 |
2900 |
0.42 0.55 0.56 |
32 29 40 |
|
|
|
||||||||||||||||
|
CQB-DG 40-25-125 |
3.8 6.3 7.5 |
22 20 18.5 |
2900 |
0.81 0.98 1.05 |
28 35 36 |
|
|
|
||||||||||||||||
|
CQB-DG 40-25-160 |
3.8 6.3 7.5 |
34 32 29 |
2900 |
1.41 1.72 1.79 |
25 32 33 |
|
|
|
||||||||||||||||
|
CQB-DG 40-25-200 |
3.8 6.3 7.5 |
52.5 50 48 |
2900 |
3.02 3.43 3.77 |
18 25 26 |
|
|
|
||||||||||||||||
|
CQB-DG 50-40-85 |
7.5 12.5 15 |
9 8 7.5 |
3.5 3.5 4.0 |
2900 |
0.46 0.56 0.61 |
40 49 50 |
|
|
|
|||||||||||||||
|
CQB-DG 50-32-105 |
7.5 12.5 15 |
13 12.5 11 |
3.5 3.5 4.0 |
2900 |
0.760 0.91 0.94 |
35 47 48 |
|
|
|
|||||||||||||||
|
CQB-DG 50-32-125 |
7.5 12.5 15 |
22 20 18.5 |
3.5 3.5 4.0 |
2900 |
1.49 1.62 1.63 |
30 42 43 |
|
|
|
|||||||||||||||
|
CQB-DG 50-32-160 |
7.5 12.5 15 |
34 32 29 |
3.5 3.5 4.0 |
2900 |
2.48 2.79 2.96 |
28 39 40 |
|
|
|
|||||||||||||||
|
CQB-DG 50-32-200 |
7.5 12.5 15 |
52.5 50 48 |
3.5 3.5 4.0 |
2900 |
5.10 5.49 6.13 |
21 31 32 |
|
|
|
|||||||||||||||
|
CQB-DG 50-32-250 |
7.5 12.5 15 |
82 80 78.5 |
3.5 3.5 4.0 |
2900 |
9.57 10.89 13.32 |
17.5 25 26 |
|
|
|
|||||||||||||||
|
CQB-DG 65-50-125 |
15 25 30 |
22 20 18.5 |
3.5 3.5 4.0 |
2900 |
2.25 2.67 2.91 |
40 51 52 |
|
|
|
|||||||||||||||
|
CQB-DG 65-50-160 |
15 25 30 |
34 32 29.5 |
3.5 3.5 4.0 |
2900 |
4.34 5.07 5.48 |
32 43 44 |
|
|
|
|||||||||||||||
|
CQB-DG 65-40-200 |
15 25 30 |
53 50 47 |
3.5 3.5 4.0 |
2900 |
8.66 9.20 10.1 |
25 37 38 |
|
|
|
|||||||||||||||
|
CQB-DG 65-40-250 |
15 25 30 |
82 80 78.5 |
3.5 3.5 4.0 |
2900 |
13.4 14.72 16.88 |
25 37 38 |
|
|
|
|||||||||||||||
|
CQB-DG 80-65-125 |
30 50 60 |
22.5 20 18 |
4.0 4.0 4.5 |
2900 |
4.48 5.24 5.55 |
41 52 53 |
|
|
|
|||||||||||||||
|
CQB-DG 80-65-160 |
30 50 60 |
34 32 29 |
4.0 4.0 4.5 |
2900 |
7.72 9.08 9.67 |
36 48 49 |
|
|
|
|||||||||||||||
|
CQB-DG 80-50-200 |
30 50 60 |
53 50 47 |
4.0 4.0 4.5 |
2900 |
12.03 14.80 16.34 |
36 46 47 |
|
|
|
|||||||||||||||
|
CQB-DG 80-50-250 |
30 50 60 |
84 80 75 |
4.0 4.0 4.5 |
2900 |
19.06 23.08 26.07 |
36 46 47 |
|
|
|
|||||||||||||||
|
CQB-DG 100-80-125 |
60 100 120 |
23 20 16.5 |
4.0 4.0 4.5 |
2900 |
8.35 9.73 9.46 |
45 56 57 |
|
|
|
|||||||||||||||
|
CQB-DG 100-80-160 |
60 100 120 |
35 32 28 |
4.0 4.0 4.5 |
2900 |
12.43 15.85 16.34 |
46 55 56 |
|
|
|
|||||||||||||||
|
CQB-DG 100-65-200 |
60 100 120 |
54 50 47 |
4.0 4.0 4.5 |
2900 |
21.01 25.69 28.44 |
42 53 56 |
|
|
|
|||||||||||||||
|
CQB-DG 100-65-250 |
60 100 120 |
86 80 74.5 |
4.0 4.0 4.5 |
2900 |
37.98 45.39 49.69 |
37 48 49 |
|
|
|
|||||||||||||||
Meaning Of Model Code
- CQB---Magnetic drive centrifugal pump
- G---High temperature
- 50---Inlet diameter(mm)
- 32---Outlet diameter(mm)
- 160---Impeller nominal diameter (mm)
Instructions
CQB-DG high temperature resistant magnetic drive pump shall be installed horizontally. Before starting, check the lubricating oil level of cooling box, and supplement it in time if the oil level is too low. Before opening the pump, the cooling water circuit shall be opened first. The opening degree of the inlet valve shall be adjusted according to the temperature of the cooling water outlet pipe after the pump is in normal operation.
When he suction level is higher than the fruit axis, open the suction pipe valve before starting. If the suction level is lower than the pump axis, the pipeline shall be equipped with bottom valve.
Before use of magnetic insulation pump, check the motor fan blade to rotate flexibly without jamming and abnormal sound, and fasten all fasteners.
Check whether the rotation direction of motor is consistent with the magnetic pump steering mark.
Slowly open the discharge valve after the motor starts, and adjust the discharge valve to the required opening after the magnetic insulation pump enters the normal working state.
Before CQB DG circulating magnetic pump stops working, the discharge valve shall be closed first, then the power supply shall be cut off, and then the cooling water pipe valve shall be closed.
Attention
- Because the cooling and lubrication of CQB-DG type high temperature resistant magnetic drive pump bearings depend on the transported medium, it is absolutely forbidden to run without load, and at the same time avoid the time-space operation caused by restart after power failure in the middle of work.
- If there are solid particles in the medium to be transported, a filter screen should be added at the inlet of the circulating magnetic pump; if there are ferromagnetic particles, a magnetic filter should be added.
- The transported medium and its temperature shall be within the allowable range of pump materials. The service temperature of the pump is < 280 ℃, the maximum working pressure is 1.6Mpa, the density is not more than 1840kg / m3,
Troubleshooting
|
Trouble |
Caused |
Exclusion method |
|
The pump does not discharge water |
1. The water pump reverses
2. Air leakage of inlet pipe
3. Insufficient water storage in pump chamber
4. The voltage is too high and the coupling slips when starting
5. The suction head is too high
6. Valve not open |
1. Change the motor wiring
2. Prevent air leakage
3. Increase water storage capacity
4. Adjust the voltage
5. Lower the pump installation position
6. Correct or change the valve |
|
Insufficient flow |
1. The suction pipe diameter is too small or clogged
2. The passage of impeller is blocked
3. The lift is too high
4. The speed is not enough |
1. Replace or clean the water inlet pipe
2. Cleaning wheel
3. Open the outlet valve
4. Restore the rated speed |
|
Low head of delivery |
1. The flow is too large
2. The speed is too low |
1. Turn down the water outlet valve
2. Restore the rated speed |
|
Too much noise |
1. The pump shaft is seriously worn
2. The bearing is seriously worn
3. The outer magnetic steel or the inner magnetic steel contacts with the isolation sleeve
4. Friction between seal ring and impeller
5. The rolling bearing in the cooling box is worn |
1. Replace the pump shaft
2. Replace the bearing
3. Remove the pump head and reassemble it
4. Replace thrust ring and sealing ring
5. Replace the rolling bearing |
|
Leakage |
1. O type sealing ring is damaged |
1. Replace O-type sealing ring |
Hot Tags: high temperature magnetic drive pump, China high temperature magnetic drive pump manufacturers, factory, magnetic impeller pump, mag drive water pump, High Temperature Magnetic Drive Pump, mag drive turbine pump, magnetic water pump