Product Overview
The CDL/CDLF series comprises vertical, single-suction, multistage centrifugal pumps. The impellers and diffusers are formed from stamped and welded stainless-steel sheet. The inlet and outlet are arranged in line, and the motor drives the pump shaft directly through a coupling. A cartridge mechanical seal is used.
The CDL version has cast-iron pump covers and base components, while the CDLF version uses stainless steel for the wetted parts to provide greater corrosion resistance. The stated flow range is 0.4–240 m³/h, with total head exceeding 300 m in some configurations. The stated liquid-temperature range is −15°C to +120°C.
The series is used in a wide range of industrial and municipal applications.
Product Features
1. High efficiency
The pump uses a hydraulic design with precision-stamped impellers and diffusers. Smooth flow passages support efficient operation. The series is stated to meet the energy-efficiency evaluation values in GB 19762.
2. Compact construction
The vertical design and in-line inlet and outlet allow the pump to be installed directly in a pipeline, helping reduce the space required in the pump room.
3. Low noise and vibration
The pump shaft is designed for good concentricity, and the rotor is dynamically balanced to support stable, low-noise operation.
4. Stainless-steel wetted parts and cartridge seal
The CDLF version uses stainless steel-typically 304 or 316-for all wetted components. It is intended for mildly corrosive liquids and drinking-water service, subject to applicable material and hygiene requirements.
The cartridge mechanical seal is designed for straightforward replacement without on-site adjustment.
5. Broad performance range
Rated flow rates range from 0.4 to 240 m³/h. The stated single-stage head is 4–60 m; additional stages provide higher total head for different system requirements.
6. Variable-frequency operation
The pump can be used with a variable-frequency drive (VFD) for applications such as constant-pressure water supply, where speed adjustment can help reduce energy consumption.
7. Standard motor configuration
The standard motor is totally enclosed and fan-cooled, with IP55 protection and Class F insulation.
Applications
Water supply and pressure boosting:
Domestic water supply and pressure boosting for high-rise buildings, residential communities, hotels and restaurants; secondary boosting at water-treatment plants.
Industrial systems:
Boiler feed, cooling-water circulation, industrial cleaning equipment, machine tools and condensate recovery.
Water treatment:
Booster service for reverse-osmosis (RO) pretreatment, ultrafiltration and electrodeionization (EDI) systems.
Fire-protection systems:
Pressure boosting or pressure maintenance for hydrant and sprinkler systems, subject to the required approvals and certifications.
HVAC and heating:
Chilled-water and cooling-water circulation in central HVAC systems, and hot-water circulation in heating systems.
Agricultural irrigation:
Garden sprinklers, greenhouse drip irrigation and flower-growing facilities.
Other services:
Washing equipment, water-supply packages and transfer of mildly corrosive chemical liquids when suitable materials are selected.
Technical Specifications
Design Standards
The source states that the pump is designed and manufactured in accordance with JB/T 8059 or JB/T 6435. Pumps for drinking-water service are stated to meet the hygiene requirements of GB/T 17219.
2. Construction
The pump is a vertical, single-suction, multistage, segmental centrifugal design. The pump shaft is directly coupled to the motor shaft through a rigid coupling. Tie rods secure the stages together. The inlet and outlet are arranged on the same side of the pump base.
3. Hydraulic-Part Materials
CDL: The impellers and diffusers are made of 304 stainless steel. The casing may be cast iron or stainless steel, and the shaft is stainless steel.
CDLF: All wetted parts-including the impellers, diffusers, casing, pump cover and base-are made of 304 or 316L stainless steel.
4. Shaft-Seal System
The pump uses a balanced cartridge mechanical seal, in single- or double-seal configurations as specified. The typical seal-face pairing is silicon carbide against graphite.
5. Motor
The standard motor is totally enclosed and fan-cooled, with a supply of 380 V / 50 Hz; other specifications can be arranged. It has Class F insulation and IP55 protection. Motor rating should be selected to cover the pump's maximum shaft-power requirement at the specified duty.
6. Operating Conditions
|
Parameter |
Stated range or specification |
|
Flow rate, Q |
0.4–240 m³/h; generally changes little as the number of stages increases |
|
Single-stage head, H₀ |
4–60 m, depending on flow |
|
Total head |
Determined by the number of stages; above 300 m for some configurations |
|
Speed, n |
2,900 r/min standard; VFD operation available |
|
Liquid temperature |
−15°C to +120°C standard; −15°C to +80°C stated for the hot-water version |
|
Rated pressure |
2.5 MPa (25 bar) or 4.0 MPa (40 bar); the source states up to 10 MPa for certain configurations |
|
Power supply |
380 V / 50 Hz three-phase or 220 V / 50 Hz single-phase; other supplies by arrangement |
|
Inlet/outlet size |
G1/2 to DN150, depending on flow size |
|
Motor power |
0.37–110 kW |
Structural Drawings

Performance Data Tables
|
Model |
Rated flow (m³/h) |
Flow range (m³/h) |
Rated head (m) |
Number of stages |
Speed (r/min) |
Motor power range (kW) |
Efficiency (%) |
Inlet/outlet size (mm) |
|
CDL/CDLF2 |
2 |
0.5~3.5 |
15~156 |
2~24 |
2900 |
0.37~2.2 |
38 |
DN25/DN25 |
|
CDL/CDLF3 |
3 |
0.8~5.0 |
12~130 |
2~20 |
2900 |
0.37~2.2 |
42 |
DN25/DN25 |
|
CDL/CDLF4 |
4 |
1.0~6.5 |
12~166 |
2~22 |
2900 |
0.37~3.0 |
46 |
DN32/DN32 |
|
CDL/CDLF5 |
5 |
1.5~8.0 |
12~180 |
2~24 |
2900 |
0.37~4.0 |
50 |
DN32/DN32 |
|
CDL/CDLF8 |
8 |
2.0~12 |
11~176 |
2~22 |
2900 |
0.75~7.5 |
55 |
DN40/DN40 |
|
CDL/CDLF10 |
10 |
3.0~15 |
10~180 |
2~22 |
2900 |
0.75~7.5 |
58 |
DN40/DN40 |
|
CDL/CDLF12 |
12 |
3.5~18 |
12~160 |
2~20 |
2900 |
1.1~11 |
60 |
DN50/DN50 |
|
CDL/CDLF16 |
16 |
5.0~24 |
12~190 |
2~22 |
2900 |
1.5~15 |
64 |
DN50/DN50 |
|
CDL/CDLF20 |
20 |
6.0~30 |
12~195 |
2~22 |
2900 |
2.2~18.5 |
66 |
DN50/DN50 |
|
CDL/CDLF32 |
32 |
10~45 |
12~210 |
2~24 |
2900 |
3.0~30 |
72 |
DN65/DN65 |
|
CDL/CDLF42 |
42 |
15~58 |
12~198 |
2~22 |
2900 |
4.0~37 |
74 |
DN65/DN65 |
|
CDL/CDLF45 |
45 |
15~62 |
12~206 |
2~22 |
2900 |
4.0~37 |
74 |
DN80/DN80 |
|
CDL/CDLF65 |
65 |
22~88 |
12~210 |
2~22 |
2900 |
5.5~55 |
76 |
DN80/DN80 |
|
CDL/CDLF85 |
85 |
30~110 |
12~204 |
2~22 |
2900 |
7.5~75 |
78 |
DN100/DN100 |
|
CDL/CDLF100 |
100 |
35~130 |
12~198 |
2~20 |
2900 |
11~90 |
78 |
DN100/DN100 |
|
CDL/CDLF120 |
120 |
40~155 |
12~210 |
2~20 |
2900 |
15~110 |
79 |
DN125/DN125 |
|
CDL/CDLF150 |
150 |
50~195 |
12~202 |
2~18 |
2900 |
15~132 |
80 |
DN125/DN125 |
|
CDL/CDLF200 |
200 |
70~260 |
15~200 |
2~18 |
2900 |
22~160 |
81 |
DN150/DN150 |
If you cannot find the required specifications or model in our product range, please contact us at any time. Our technical specialists will provide prompt model selection assistance and a customized technical solution.
Hot Tags: cdl/cdlf vertical multistage centrifugal pump, China cdl/cdlf vertical multistage centrifugal pump manufacturers, factory