SH Double-Suction Pump Horizontally Split-Case Centrifugal Pump

SH Double-Suction Pump Horizontally Split-Case Centrifugal Pump

The SH double-suction pump is a single-stage, double-suction, horizontally split-case centrifugal pump designed to transfer clean water and liquids with physical and chemical properties similar to those of water.
The pump is installed horizontally, with the casing split horizontally along the shaft centerline to form an upper casing and a lower casing. The rotor assembly consists of the impeller, shaft, shaft sleeves, and other components, and is installed horizontally inside the pump casing.
The impeller adopts a double-suction design, allowing the liquid to enter simultaneously from both sides of the impeller. This configuration provides a high flow rate and automatically balances the axial thrust.
Send Inquiry
Description

Product Overview

 

The SH double-suction pump is a single-stage, double-suction, horizontally split-case centrifugal pump designed to transfer clean water and liquids with physical and chemical properties similar to those of water.

 

The pump is installed horizontally, with the casing split horizontally along the shaft centerline to form an upper casing and a lower casing. The rotor assembly consists of the impeller, shaft, shaft sleeves, and other components, and is installed horizontally inside the pump casing.

 

The impeller adopts a double-suction design, allowing the liquid to enter simultaneously from both sides of the impeller. This configuration provides a high flow rate and automatically balances the axial thrust.

 

According to industry naming conventions:

  • For an SH-type pump, the suction inlet is located on the left when viewed from the motor end, and the pump rotates counterclockwise.
  • For an S-type pump, the suction inlet is located on the right, and the pump rotates clockwise.

The impeller outside diameter can be trimmed to adapt the pump to different operating conditions. The designations A and B indicate the first and second impeller diameter reductions, respectively.

 

Model Designation Example

Taking 10SH-13A as an example:

  • 10 - Suction inlet diameter divided by 25; the actual inlet diameter is 250 mm
  • SH - Single-stage, double-suction centrifugal pump
  • 13 - Specific speed divided by 10; the actual specific speed is 130
  • A - First impeller diameter trimming

 

Product Features

 

Horizontally Split Casing for Easy Maintenance

The pump casing and cover are split horizontally along the shaft centerline. During maintenance, the pump cover can be lifted to inspect or replace internal components without dismantling the inlet and outlet piping or the motor.

During assembly, the horizontal split gasket is positioned between the casing and cover. The cover is then installed and secured by tightening the nuts.

Double-Suction Impeller with Automatic Axial-Thrust Balancing

The double-suction impeller allows the liquid to enter from both the left and right sides simultaneously.

The axial forces generated on both sides of the impeller offset one another, ensuring smooth and reliable operation while significantly extending bearing service life.

Complete Rotor Assembly for Accurate Positioning

The rotor assembly can be installed into or removed from the pump casing as a complete unit. This facilitates adjustment of the impeller's axial position.

The impeller can be accurately positioned between the two double-suction wear rings before the rotor is secured, ensuring precise running clearances.

Optional Packing or Mechanical Seal

The shaft is generally sealed with soft packing. A mechanical seal can also be installed for special orders.

The packing compression must be properly adjusted:

Excessive compression may cause the shaft sleeve to overheat and increase power consumption.

Insufficient compression may result in excessive leakage and reduced pump efficiency.

After assembly, the pump shaft should be rotated manually. It should turn smoothly and evenly without rubbing or interference.

Customizable Materials for Different Media

The materials of the impeller, wear rings, and shaft sleeves can be changed to enable the pump to handle water containing suspended sand or sediment.

Changing the materials of the pump casing and cover can increase the allowable inlet pressure, making the pump suitable for closed-loop applications such as air-conditioning and heating systems.

Copper impellers and copper wear rings can be used for transferring oil products.

Flexible Operation at Reduced Speed

The pump speed must not be increased arbitrarily. However, the pump can be operated at a reduced speed.

After speed reduction, the flow rate, head, and shaft power vary according to established proportional relationships with pump speed. This allows the pump to adapt flexibly to different operating conditions without replacing the impeller.

Applications

 

The SH double-suction pump is widely used to transfer clean water and liquids with physical and chemical properties similar to those of water.

The standard allowable medium temperature is ≤ 80°C. With cooling water supplied to both bearings, the pump can handle media up to 130°C.

Typical applications include the following:

Municipal Water Supply and Drainage: Water supply in municipal water plants, pressurization of municipal pipeline networks, and water-transfer systems in wastewater treatment facilities.

Industrial Water Supply: Circulating water, cooling water, and process water in steel and metallurgy plants, petrochemical and oil-refining facilities, thermal power plants, chemical-fiber plants, textile mills, and sugar refineries.

Air-Conditioning and Heating Systems: Circulating water in district heating systems, air-conditioning cooling-water circulation, and other closed-loop applications.

Agricultural Drainage and Irrigation: Drainage, irrigation, and water-transfer projects in agricultural water-conservancy systems.

Fire Protection Systems: Water supply for fire-protection systems in factories, mines, and large buildings.

Mine Dewatering: Discharge of mine water and water supply in mining areas.

Power Plant Water Supply: Condenser circulating cooling water and auxiliary-system water supply in nuclear and thermal power plants.

 

Technical Specifications

 

1.Design Standards

The pump is designed and manufactured according to the manufacturer's enterprise standards. Production can also be organized in accordance with applicable Chinese GB and HG standards, as well as relevant American API standards.

 

2. Pump Configuration

The SH pump is a single-stage, double-suction, horizontal, horizontally split-case centrifugal pump.

The pump casing is split horizontally along the shaft centerline. The impeller adopts a double-suction design, and the rotor is supported by bearings at both ends.

When viewed from the motor end:

The SH-type pump rotates counterclockwise, with the suction inlet on the left.

The S-type pump rotates clockwise, with the suction inlet on the right.

 

3. Main Components

The main components include:

  • Pump casing
  • Pump cover
  • Impeller
  • Shaft
  • Wear rings
  • Shaft sleeves
  • Bearing housings
  • Packing glands
  • Coupling
  • Other associated components

The wear rings are installed between the impeller suction and discharge passages and the pump casing. They can be replaced after wear to maintain the correct running clearance and volumetric efficiency.

 

4. Assembly and Disassembly

Assembly sequence

Install the complete rotor assembly into the pump casing.

Adjust the axial position of the impeller so that it is centered.

Secure the bearing-housing covers.

Install the packing.

Position the horizontal split-case gasket.

Install the pump cover.

Tighten the pump-cover nuts.

Install the packing glands.

Disassembly is performed in the reverse order.

 

5. Installation Requirements

a. The available net positive suction head, NPSHA, determined by the pump installation elevation and the hydraulic losses in the suction piping, must be greater than the pump's required net positive suction head, NPSHR.

b. Level the pump using wedge-shaped shims. Pour concrete between the foundation and the pump feet. After the concrete has cured, tighten the foundation bolts and recheck the pump level.

c. Align the motor shaft with the pump shaft:

The allowable difference in concentricity between the outside diameters of the two coupling halves is ≤ 0.1 mm.

The allowable circumferential variation in the coupling end-face gap is ≤ 0.3 mm.

d. The inlet and outlet piping must be supported independently and must not be supported by the pump casing. The suction piping must be completely airtight and designed to prevent air pockets from forming.

e. When the pump is installed above the water level of the suction source, a foot valve should generally be installed, or vacuum priming should be used before starting the pump.

 

6. Operation and Maintenance

a. The bearing temperature should not exceed 75°C. Calcium-based grease should be used for lubrication. The recommended grease quantity is approximately one-third to one-half of the bearing-housing volume.

b. When the packing becomes worn, the packing gland may be tightened appropriately. If the packing is excessively worn, it should be replaced promptly.

c. Tighten the packing-gland nuts evenly so that the leakage appears as a slow dripping flow. Monitor the temperature rise around the packing chamber.

d. Inspect the flexible coupling regularly and monitor the temperature rise of the motor bearings.

e. If abnormal noise or unusual operating sounds are detected, stop the pump immediately and inspect it. If the pump will be out of service for an extended period, disassemble the pump, dry the components, and apply rust-preventive oil to the machined surfaces.

 

7. Operating Conditions

Parameter

Specification

Flow rate

112–6,330 m³/h; up to 12,500 m³/h for special configurations

Head

8.6–140 m

Speed

1,450 / 970 / 730 r/min

Medium temperature

≤ 80°C; up to 130°C when cooling water is supplied to both bearings

Allowable inlet pressure

Normally no higher than 0.6 MPa; 1.0–1.6 MPa available for special configurations

 

8. General Performance Range of the SH Double-Suction Pump

  • Flow rate, Q: 112–6,330 m³/h; up to 12,500 m³/h for special configurations
  • Head, H: 8.6–140 m; a broader performance range is available with A/B impeller trimming
  • Speed, n: 1,450 / 970 / 730 r/min, depending on the pump size
  • Medium temperature: ≤ 80°C; up to 130°C with cooling water supplied to both bearings
  • Rated power: 18.5–1,600 kW, calculated according to the operating conditions
  • Efficiency, η: 56%–92%; higher flow rates generally correspond to higher efficiency
  • Required NPSH, NPSHR: 3.4–8.0 m, depending on the model
  • Suction inlet diameter: 150–800 mm, depending on the pump size

 

Structural Drawings

 

9

 

 

Performance Data Tables

 

Pump Model

Flow Rate (m³/h)

Head (m)

Speed (r/min)

Shaft Power (kW)

Motor Power (kW)

Efficiency (%)

Required NPSH (m)

Impeller Diameter (mm)

Pump Weight (kg)

Base Weight (kg)

150S,SH-100

160

100

2950

59.8

75

73

4.5

-

168

112

150S,SH-78

160

78

2950

46

55

74

4.5

245

158

112

150S,SH-78A

140

60

2950

31.9

45

72

4.5

223

158

95

150S,SH-50

160

50

2950

27.6

37

79

4.5

206

147

112

150S,SH-50A

140

39

2950

19.9

30

75

4.5

185

147

95

150S,SH-50B

133

36

2950

18.6

22

70

4.5

170

147

80

200S,SH-95

280

95

2950

94.4

125

77

5

282

240

-

200S,SH-95A

268

87

2950

84.8

110

75

5

270

240

-

200S,SH-95B

245

72

2950

64.9

75

74

5

250

240

-

200S,SH-63

280

63

2950

59.5

75

81

5

235

187

135

200S,SH-63A

245

48

2950

41.6

55

77

5

210

187

124

200S,SH-42

280

42

2950

37.7

45

85

5

204

219

108

200S,SH-42A

245

36

2950

30

37

80

5

193

219

108

250S,SH-65

485

65

1450

108.5

135

79

3.8

450

518

-

250S,SH-65A

420

48

1450

71.1

90

77

3.8

400

518

-

250S,SH-39

485

39

1450

62

75

83

3.8

367

400

240

250S,SH-39A

420

29

1450

42.5

55

78

3.8

328

400

233

250S,SH-24

485

24

1450

36.9

45

86

3.8

285

305

225

250S,SH-24A

420

20

1450

27.6

37

83

3.8

265

305

215

250S,SH-14

485

14

1450

21.7

30

85

3.8

245

305

225

250S,SH-14A

420

10

1450

14.1

18.5

81

3.8

214

305

215

300S,SH-90

790

90

1450

242

320

80

4.8

-

840

-

300S,SH-90A

756

78

1450

217

280

74

4.8

-

840

-

300S,SH-90B

720

67

1450

180

220

73

4.8

-

840

-

300S,SH-58

790

58

1450

148.2

180

84

4.8

445

599

-

300S,SH-58A

735

50

1450

122

155

82

4.8

419

599

-

300S,SH-58B

685

43

1450

100.3

135

80

4.8

394

599

-

300S,SH-32

790

32

1450

79

90

87

4.8

348

709

-

300S,SH-32A

700

26

1450

60

75

84

4.8

318

709

-

300S,SH-19

790

19

1450

46.9

55

87

4.8

290

434

485

300S,SH-19A

700

15

1450

34.8

45

82

4.8

260

434

490

300S,SH-12

790

12

1450

31.1

37

83

4.8

251

413

243

300S,SH-12A

700

10

1450

24.1

30

79

4.8

251(R121Cutting)

413

237

350S,SH-125

1260

125

1450

531

680

81

5.5

655

1580

-

350S,SH-125A

1181

112

1450

462

570

78

5.5

633

1580

-

350S,SH-125B

1098

96

1450

373

500

77

5.5

615

1580

-

350S,SH-75

1260

75

1450

304

360

85

5.5

503

1200

-

350S,SH-75A

1170

65

1450

247

280

84

5.5

470

1200

-

350S,SH-75B

1080

55

1450

197

220

82

5.5

443

1200

-

350S,SH-44

1260

44

1450

177.6

220

87

5.5

406

1105

-

350S,SH-44A

1116

36

1450

130

160

84

5.5

370

1105

-

350S,SH-26

1260

26

1450

101.4

135

88

5.5

340

672

-

350S,SH-26A

1130

21

1450

77.8

90

83

5.5

310

672

-

350S,SH-16

1260

16

1450

63.8

75

86

5.5

290

632

-

350S,SH-16A

1130

12

1450

45.6

55

81

5.5

250(R121Cutting)

632

-

500S,SH-98

2020

98

970

678

780

79.5

6

860

-

-

500S,SH-98A

1872

83

970

540

650

78.5

6

800

-

-

500S,SH-98B

1746

74

970

452

550

78

6

745

-

-

500S,SH-59

2020

59

970

392

460

83

6

675

-

-

500S,SH-59A

1872

49

970

333

380

75

6

630

-

-

500S,SH-59B

1746

40

970

258

310

74

6

585

-

-

500S,SH-35

2020

35

970

219

280

88

6

530

-

-

500S,SH-35A

1746

27

970

152

215

85

6

498

-

-

500S,SH-22

2020

22

970

144.2

185

84

6

460

1722

-

500S,SH-22A

1746

17

970

101

130

80

6

410

1722

-

500S,SH-13

2020

13

970

86.2

115

83

6

390

-

-

600S,SH-75

3170

75

970

761

850

85

7.5

782

-

-

600S,SH-75A

2880

62

970

608.2

780

80

7.5

716

-

-

600S,SH-47

3170

47

970

461

550

88

7.5

626

-

-

600S,SH-32A

3170

32

970

314

380

88

7.5

540

-

-

600S,SH-32A

2880

27

970

246

280

86

7.5

500

-

-

600S,SH-32B

2628

22

970

187.4

240

84

7.5

-

-

-

600S,SH-22

3170

22

970

215.7

250

88

7

485

-

-

600S,SH-22A

2880

18

970

161.4

185

87

7

-

-

-

800S,SH-22

5500

22

730

370.2

450

89

7

-

1222

-

800S,SH-22A

4830

17

730

254.1

315

88

7

-

1085

-

800S,SH-22A(Light-Duty Operating Conditions)

3870

11

585

133.3

185

87

7

-

1075

-

800S,SH-32

5500

32

730

538.5

630

89

7

740

6723

-

800S,SH-32A

4950

26

730

378.3

450

88

7

740

6723

-

800S,SH-32A(Light-Duty Operating Conditions)

3960

16.5

585

204.5

250

87

4.5

680

6723

-

800S,SH-47

5500

47

730

782

1000

90

6.5

-

-

-

800S,SH-47A

5070

40

730

620.5

710

89

6.5

-

-

-

800S,SH-47A(Light-Duty Operating Conditions)

4060

25

585

314.1

355

88

6

-

-

-

800S,SH-76

5500

76

730

1293.6

1600

88

6

-

-

-

800S,SH-76A

5080

65

730

1033.6

1250

87

6

-

-

-

800S,SH-76A(Light-Duty Operating Conditions)

4070

42

585

541.3

630

86

4

-

-

-

800S,SH-76B

4680

55

730

824.7

1000

85

6

-

-

-

800S,SH-76B(Light-Duty Operating Conditions)

3750

35

585

425.5

500

84

4

-

-

-

If you cannot find the required specifications or model in our product range, please contact us at any time. Our technical specialists will provide prompt model selection assistance and a customized technical solution.

Hot Tags: sh double-suction pump horizontally split-case centrifugal pump, China sh double-suction pump horizontally split-case centrifugal pump manufacturers, factory

Send Inquiry