Product Overview
The SH double-suction pump is a single-stage, double-suction, horizontally split-case centrifugal pump designed to transfer clean water and liquids with physical and chemical properties similar to those of water.
The pump is installed horizontally, with the casing split horizontally along the shaft centerline to form an upper casing and a lower casing. The rotor assembly consists of the impeller, shaft, shaft sleeves, and other components, and is installed horizontally inside the pump casing.
The impeller adopts a double-suction design, allowing the liquid to enter simultaneously from both sides of the impeller. This configuration provides a high flow rate and automatically balances the axial thrust.
According to industry naming conventions:
- For an SH-type pump, the suction inlet is located on the left when viewed from the motor end, and the pump rotates counterclockwise.
- For an S-type pump, the suction inlet is located on the right, and the pump rotates clockwise.
The impeller outside diameter can be trimmed to adapt the pump to different operating conditions. The designations A and B indicate the first and second impeller diameter reductions, respectively.
Model Designation Example
Taking 10SH-13A as an example:
- 10 - Suction inlet diameter divided by 25; the actual inlet diameter is 250 mm
- SH - Single-stage, double-suction centrifugal pump
- 13 - Specific speed divided by 10; the actual specific speed is 130
- A - First impeller diameter trimming
Product Features
Horizontally Split Casing for Easy Maintenance
The pump casing and cover are split horizontally along the shaft centerline. During maintenance, the pump cover can be lifted to inspect or replace internal components without dismantling the inlet and outlet piping or the motor.
During assembly, the horizontal split gasket is positioned between the casing and cover. The cover is then installed and secured by tightening the nuts.
Double-Suction Impeller with Automatic Axial-Thrust Balancing
The double-suction impeller allows the liquid to enter from both the left and right sides simultaneously.
The axial forces generated on both sides of the impeller offset one another, ensuring smooth and reliable operation while significantly extending bearing service life.
Complete Rotor Assembly for Accurate Positioning
The rotor assembly can be installed into or removed from the pump casing as a complete unit. This facilitates adjustment of the impeller's axial position.
The impeller can be accurately positioned between the two double-suction wear rings before the rotor is secured, ensuring precise running clearances.
Optional Packing or Mechanical Seal
The shaft is generally sealed with soft packing. A mechanical seal can also be installed for special orders.
The packing compression must be properly adjusted:
Excessive compression may cause the shaft sleeve to overheat and increase power consumption.
Insufficient compression may result in excessive leakage and reduced pump efficiency.
After assembly, the pump shaft should be rotated manually. It should turn smoothly and evenly without rubbing or interference.
Customizable Materials for Different Media
The materials of the impeller, wear rings, and shaft sleeves can be changed to enable the pump to handle water containing suspended sand or sediment.
Changing the materials of the pump casing and cover can increase the allowable inlet pressure, making the pump suitable for closed-loop applications such as air-conditioning and heating systems.
Copper impellers and copper wear rings can be used for transferring oil products.
Flexible Operation at Reduced Speed
The pump speed must not be increased arbitrarily. However, the pump can be operated at a reduced speed.
After speed reduction, the flow rate, head, and shaft power vary according to established proportional relationships with pump speed. This allows the pump to adapt flexibly to different operating conditions without replacing the impeller.
Applications
The SH double-suction pump is widely used to transfer clean water and liquids with physical and chemical properties similar to those of water.
The standard allowable medium temperature is ≤ 80°C. With cooling water supplied to both bearings, the pump can handle media up to 130°C.
Typical applications include the following:
Municipal Water Supply and Drainage: Water supply in municipal water plants, pressurization of municipal pipeline networks, and water-transfer systems in wastewater treatment facilities.
Industrial Water Supply: Circulating water, cooling water, and process water in steel and metallurgy plants, petrochemical and oil-refining facilities, thermal power plants, chemical-fiber plants, textile mills, and sugar refineries.
Air-Conditioning and Heating Systems: Circulating water in district heating systems, air-conditioning cooling-water circulation, and other closed-loop applications.
Agricultural Drainage and Irrigation: Drainage, irrigation, and water-transfer projects in agricultural water-conservancy systems.
Fire Protection Systems: Water supply for fire-protection systems in factories, mines, and large buildings.
Mine Dewatering: Discharge of mine water and water supply in mining areas.
Power Plant Water Supply: Condenser circulating cooling water and auxiliary-system water supply in nuclear and thermal power plants.
Technical Specifications
1.Design Standards
The pump is designed and manufactured according to the manufacturer's enterprise standards. Production can also be organized in accordance with applicable Chinese GB and HG standards, as well as relevant American API standards.
2. Pump Configuration
The SH pump is a single-stage, double-suction, horizontal, horizontally split-case centrifugal pump.
The pump casing is split horizontally along the shaft centerline. The impeller adopts a double-suction design, and the rotor is supported by bearings at both ends.
When viewed from the motor end:
The SH-type pump rotates counterclockwise, with the suction inlet on the left.
The S-type pump rotates clockwise, with the suction inlet on the right.
3. Main Components
The main components include:
- Pump casing
- Pump cover
- Impeller
- Shaft
- Wear rings
- Shaft sleeves
- Bearing housings
- Packing glands
- Coupling
- Other associated components
The wear rings are installed between the impeller suction and discharge passages and the pump casing. They can be replaced after wear to maintain the correct running clearance and volumetric efficiency.
4. Assembly and Disassembly
Assembly sequence
Install the complete rotor assembly into the pump casing.
Adjust the axial position of the impeller so that it is centered.
Secure the bearing-housing covers.
Install the packing.
Position the horizontal split-case gasket.
Install the pump cover.
Tighten the pump-cover nuts.
Install the packing glands.
Disassembly is performed in the reverse order.
5. Installation Requirements
a. The available net positive suction head, NPSHA, determined by the pump installation elevation and the hydraulic losses in the suction piping, must be greater than the pump's required net positive suction head, NPSHR.
b. Level the pump using wedge-shaped shims. Pour concrete between the foundation and the pump feet. After the concrete has cured, tighten the foundation bolts and recheck the pump level.
c. Align the motor shaft with the pump shaft:
The allowable difference in concentricity between the outside diameters of the two coupling halves is ≤ 0.1 mm.
The allowable circumferential variation in the coupling end-face gap is ≤ 0.3 mm.
d. The inlet and outlet piping must be supported independently and must not be supported by the pump casing. The suction piping must be completely airtight and designed to prevent air pockets from forming.
e. When the pump is installed above the water level of the suction source, a foot valve should generally be installed, or vacuum priming should be used before starting the pump.
6. Operation and Maintenance
a. The bearing temperature should not exceed 75°C. Calcium-based grease should be used for lubrication. The recommended grease quantity is approximately one-third to one-half of the bearing-housing volume.
b. When the packing becomes worn, the packing gland may be tightened appropriately. If the packing is excessively worn, it should be replaced promptly.
c. Tighten the packing-gland nuts evenly so that the leakage appears as a slow dripping flow. Monitor the temperature rise around the packing chamber.
d. Inspect the flexible coupling regularly and monitor the temperature rise of the motor bearings.
e. If abnormal noise or unusual operating sounds are detected, stop the pump immediately and inspect it. If the pump will be out of service for an extended period, disassemble the pump, dry the components, and apply rust-preventive oil to the machined surfaces.
7. Operating Conditions
|
Parameter |
Specification |
|
Flow rate |
112–6,330 m³/h; up to 12,500 m³/h for special configurations |
|
Head |
8.6–140 m |
|
Speed |
1,450 / 970 / 730 r/min |
|
Medium temperature |
≤ 80°C; up to 130°C when cooling water is supplied to both bearings |
|
Allowable inlet pressure |
Normally no higher than 0.6 MPa; 1.0–1.6 MPa available for special configurations |
8. General Performance Range of the SH Double-Suction Pump
- Flow rate, Q: 112–6,330 m³/h; up to 12,500 m³/h for special configurations
- Head, H: 8.6–140 m; a broader performance range is available with A/B impeller trimming
- Speed, n: 1,450 / 970 / 730 r/min, depending on the pump size
- Medium temperature: ≤ 80°C; up to 130°C with cooling water supplied to both bearings
- Rated power: 18.5–1,600 kW, calculated according to the operating conditions
- Efficiency, η: 56%–92%; higher flow rates generally correspond to higher efficiency
- Required NPSH, NPSHR: 3.4–8.0 m, depending on the model
- Suction inlet diameter: 150–800 mm, depending on the pump size
Structural Drawings

Performance Data Tables
|
Pump Model |
Flow Rate (m³/h) |
Head (m) |
Speed (r/min) |
Shaft Power (kW) |
Motor Power (kW) |
Efficiency (%) |
Required NPSH (m) |
Impeller Diameter (mm) |
Pump Weight (kg) |
Base Weight (kg) |
|
150S,SH-100 |
160 |
100 |
2950 |
59.8 |
75 |
73 |
4.5 |
- |
168 |
112 |
|
150S,SH-78 |
160 |
78 |
2950 |
46 |
55 |
74 |
4.5 |
245 |
158 |
112 |
|
150S,SH-78A |
140 |
60 |
2950 |
31.9 |
45 |
72 |
4.5 |
223 |
158 |
95 |
|
150S,SH-50 |
160 |
50 |
2950 |
27.6 |
37 |
79 |
4.5 |
206 |
147 |
112 |
|
150S,SH-50A |
140 |
39 |
2950 |
19.9 |
30 |
75 |
4.5 |
185 |
147 |
95 |
|
150S,SH-50B |
133 |
36 |
2950 |
18.6 |
22 |
70 |
4.5 |
170 |
147 |
80 |
|
200S,SH-95 |
280 |
95 |
2950 |
94.4 |
125 |
77 |
5 |
282 |
240 |
- |
|
200S,SH-95A |
268 |
87 |
2950 |
84.8 |
110 |
75 |
5 |
270 |
240 |
- |
|
200S,SH-95B |
245 |
72 |
2950 |
64.9 |
75 |
74 |
5 |
250 |
240 |
- |
|
200S,SH-63 |
280 |
63 |
2950 |
59.5 |
75 |
81 |
5 |
235 |
187 |
135 |
|
200S,SH-63A |
245 |
48 |
2950 |
41.6 |
55 |
77 |
5 |
210 |
187 |
124 |
|
200S,SH-42 |
280 |
42 |
2950 |
37.7 |
45 |
85 |
5 |
204 |
219 |
108 |
|
200S,SH-42A |
245 |
36 |
2950 |
30 |
37 |
80 |
5 |
193 |
219 |
108 |
|
250S,SH-65 |
485 |
65 |
1450 |
108.5 |
135 |
79 |
3.8 |
450 |
518 |
- |
|
250S,SH-65A |
420 |
48 |
1450 |
71.1 |
90 |
77 |
3.8 |
400 |
518 |
- |
|
250S,SH-39 |
485 |
39 |
1450 |
62 |
75 |
83 |
3.8 |
367 |
400 |
240 |
|
250S,SH-39A |
420 |
29 |
1450 |
42.5 |
55 |
78 |
3.8 |
328 |
400 |
233 |
|
250S,SH-24 |
485 |
24 |
1450 |
36.9 |
45 |
86 |
3.8 |
285 |
305 |
225 |
|
250S,SH-24A |
420 |
20 |
1450 |
27.6 |
37 |
83 |
3.8 |
265 |
305 |
215 |
|
250S,SH-14 |
485 |
14 |
1450 |
21.7 |
30 |
85 |
3.8 |
245 |
305 |
225 |
|
250S,SH-14A |
420 |
10 |
1450 |
14.1 |
18.5 |
81 |
3.8 |
214 |
305 |
215 |
|
300S,SH-90 |
790 |
90 |
1450 |
242 |
320 |
80 |
4.8 |
- |
840 |
- |
|
300S,SH-90A |
756 |
78 |
1450 |
217 |
280 |
74 |
4.8 |
- |
840 |
- |
|
300S,SH-90B |
720 |
67 |
1450 |
180 |
220 |
73 |
4.8 |
- |
840 |
- |
|
300S,SH-58 |
790 |
58 |
1450 |
148.2 |
180 |
84 |
4.8 |
445 |
599 |
- |
|
300S,SH-58A |
735 |
50 |
1450 |
122 |
155 |
82 |
4.8 |
419 |
599 |
- |
|
300S,SH-58B |
685 |
43 |
1450 |
100.3 |
135 |
80 |
4.8 |
394 |
599 |
- |
|
300S,SH-32 |
790 |
32 |
1450 |
79 |
90 |
87 |
4.8 |
348 |
709 |
- |
|
300S,SH-32A |
700 |
26 |
1450 |
60 |
75 |
84 |
4.8 |
318 |
709 |
- |
|
300S,SH-19 |
790 |
19 |
1450 |
46.9 |
55 |
87 |
4.8 |
290 |
434 |
485 |
|
300S,SH-19A |
700 |
15 |
1450 |
34.8 |
45 |
82 |
4.8 |
260 |
434 |
490 |
|
300S,SH-12 |
790 |
12 |
1450 |
31.1 |
37 |
83 |
4.8 |
251 |
413 |
243 |
|
300S,SH-12A |
700 |
10 |
1450 |
24.1 |
30 |
79 |
4.8 |
251(R121Cutting) |
413 |
237 |
|
350S,SH-125 |
1260 |
125 |
1450 |
531 |
680 |
81 |
5.5 |
655 |
1580 |
- |
|
350S,SH-125A |
1181 |
112 |
1450 |
462 |
570 |
78 |
5.5 |
633 |
1580 |
- |
|
350S,SH-125B |
1098 |
96 |
1450 |
373 |
500 |
77 |
5.5 |
615 |
1580 |
- |
|
350S,SH-75 |
1260 |
75 |
1450 |
304 |
360 |
85 |
5.5 |
503 |
1200 |
- |
|
350S,SH-75A |
1170 |
65 |
1450 |
247 |
280 |
84 |
5.5 |
470 |
1200 |
- |
|
350S,SH-75B |
1080 |
55 |
1450 |
197 |
220 |
82 |
5.5 |
443 |
1200 |
- |
|
350S,SH-44 |
1260 |
44 |
1450 |
177.6 |
220 |
87 |
5.5 |
406 |
1105 |
- |
|
350S,SH-44A |
1116 |
36 |
1450 |
130 |
160 |
84 |
5.5 |
370 |
1105 |
- |
|
350S,SH-26 |
1260 |
26 |
1450 |
101.4 |
135 |
88 |
5.5 |
340 |
672 |
- |
|
350S,SH-26A |
1130 |
21 |
1450 |
77.8 |
90 |
83 |
5.5 |
310 |
672 |
- |
|
350S,SH-16 |
1260 |
16 |
1450 |
63.8 |
75 |
86 |
5.5 |
290 |
632 |
- |
|
350S,SH-16A |
1130 |
12 |
1450 |
45.6 |
55 |
81 |
5.5 |
250(R121Cutting) |
632 |
- |
|
500S,SH-98 |
2020 |
98 |
970 |
678 |
780 |
79.5 |
6 |
860 |
- |
- |
|
500S,SH-98A |
1872 |
83 |
970 |
540 |
650 |
78.5 |
6 |
800 |
- |
- |
|
500S,SH-98B |
1746 |
74 |
970 |
452 |
550 |
78 |
6 |
745 |
- |
- |
|
500S,SH-59 |
2020 |
59 |
970 |
392 |
460 |
83 |
6 |
675 |
- |
- |
|
500S,SH-59A |
1872 |
49 |
970 |
333 |
380 |
75 |
6 |
630 |
- |
- |
|
500S,SH-59B |
1746 |
40 |
970 |
258 |
310 |
74 |
6 |
585 |
- |
- |
|
500S,SH-35 |
2020 |
35 |
970 |
219 |
280 |
88 |
6 |
530 |
- |
- |
|
500S,SH-35A |
1746 |
27 |
970 |
152 |
215 |
85 |
6 |
498 |
- |
- |
|
500S,SH-22 |
2020 |
22 |
970 |
144.2 |
185 |
84 |
6 |
460 |
1722 |
- |
|
500S,SH-22A |
1746 |
17 |
970 |
101 |
130 |
80 |
6 |
410 |
1722 |
- |
|
500S,SH-13 |
2020 |
13 |
970 |
86.2 |
115 |
83 |
6 |
390 |
- |
- |
|
600S,SH-75 |
3170 |
75 |
970 |
761 |
850 |
85 |
7.5 |
782 |
- |
- |
|
600S,SH-75A |
2880 |
62 |
970 |
608.2 |
780 |
80 |
7.5 |
716 |
- |
- |
|
600S,SH-47 |
3170 |
47 |
970 |
461 |
550 |
88 |
7.5 |
626 |
- |
- |
|
600S,SH-32A |
3170 |
32 |
970 |
314 |
380 |
88 |
7.5 |
540 |
- |
- |
|
600S,SH-32A |
2880 |
27 |
970 |
246 |
280 |
86 |
7.5 |
500 |
- |
- |
|
600S,SH-32B |
2628 |
22 |
970 |
187.4 |
240 |
84 |
7.5 |
- |
- |
- |
|
600S,SH-22 |
3170 |
22 |
970 |
215.7 |
250 |
88 |
7 |
485 |
- |
- |
|
600S,SH-22A |
2880 |
18 |
970 |
161.4 |
185 |
87 |
7 |
- |
- |
- |
|
800S,SH-22 |
5500 |
22 |
730 |
370.2 |
450 |
89 |
7 |
- |
1222 |
- |
|
800S,SH-22A |
4830 |
17 |
730 |
254.1 |
315 |
88 |
7 |
- |
1085 |
- |
|
800S,SH-22A(Light-Duty Operating Conditions) |
3870 |
11 |
585 |
133.3 |
185 |
87 |
7 |
- |
1075 |
- |
|
800S,SH-32 |
5500 |
32 |
730 |
538.5 |
630 |
89 |
7 |
740 |
6723 |
- |
|
800S,SH-32A |
4950 |
26 |
730 |
378.3 |
450 |
88 |
7 |
740 |
6723 |
- |
|
800S,SH-32A(Light-Duty Operating Conditions) |
3960 |
16.5 |
585 |
204.5 |
250 |
87 |
4.5 |
680 |
6723 |
- |
|
800S,SH-47 |
5500 |
47 |
730 |
782 |
1000 |
90 |
6.5 |
- |
- |
- |
|
800S,SH-47A |
5070 |
40 |
730 |
620.5 |
710 |
89 |
6.5 |
- |
- |
- |
|
800S,SH-47A(Light-Duty Operating Conditions) |
4060 |
25 |
585 |
314.1 |
355 |
88 |
6 |
- |
- |
- |
|
800S,SH-76 |
5500 |
76 |
730 |
1293.6 |
1600 |
88 |
6 |
- |
- |
- |
|
800S,SH-76A |
5080 |
65 |
730 |
1033.6 |
1250 |
87 |
6 |
- |
- |
- |
|
800S,SH-76A(Light-Duty Operating Conditions) |
4070 |
42 |
585 |
541.3 |
630 |
86 |
4 |
- |
- |
- |
|
800S,SH-76B |
4680 |
55 |
730 |
824.7 |
1000 |
85 |
6 |
- |
- |
- |
|
800S,SH-76B(Light-Duty Operating Conditions) |
3750 |
35 |
585 |
425.5 |
500 |
84 |
4 |
- |
- |
- |
If you cannot find the required specifications or model in our product range, please contact us at any time. Our technical specialists will provide prompt model selection assistance and a customized technical solution.
Hot Tags: sh double-suction pump horizontally split-case centrifugal pump, China sh double-suction pump horizontally split-case centrifugal pump manufacturers, factory